background image

 



 Ethernet

 

Communication Converter

 

 

 

IMR02E13-E1

 

 

Thank you for purchasing this RKC product. In order to achieve maximum performance and 
ensure proper operation of the instrument, carefully read all the instructions in this manual. 
Please place the manual in a convenient location for easy reference. 
This manual describes the mounting, wiring and specifications only. 
 
 
 
 
 
 

 

 

Product check 

 
 
 
 
 

 

 

Safety precautions

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 
 
 

  This product is intended for use with industrial machines, test and measuring equipment. 

(It is not designed for use with medical equipment and nuclear energy plant.) 

  In a domestic environment, this instrument may cause radio interference, in which case the 

user may be required to take additional measures. 

  Provide reinforced insulation between the wire for the input signal and the wires for instrument 

power supply, source of power and loads. 

  Be sure to provide an appropriate surge control circuit respectively for the following:   

  If input/output or signal lines within the building are longer than 30 meters. 

  If input/output or signal lines leave the building, regardless the length. 

 This instrument is designed for installation in an enclosed instrumentation panel. All 

high-voltage connections such as power supply terminals must be enclosed in the 
instrumentation panel to avoid electric shock to operating personnel. 

  All precautions described in this manual should be taken to avoid damage to the instrument or 

equipment. 

 If the equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired. 

  All wiring must be in accordance with local codes and regulations. 

 To prevent instrument damage as a result of failure, protect the power line and the 

input/output lines from high currents with a suitable overcurrent protection device with 
adequate breaking capacity such as a fuse, circuit breaker, etc. 

  A malfunction in this product may occasionally make control operations impossible or prevent 

alarm outputs, resulting in a possible hazard. Take appropriate measures in the end use to 
prevent hazards in the event of malfunction. 

  Prevent metal fragments or lead wire scraps from falling inside instrument case to avoid 

electric shock, fire or malfunction. 

  Tighten each terminal screw to the specified torque found in the manual to avoid electric 

shock, fire or malfunction. 

  For proper operation of this instrument, provide adequate ventilation for heat dissipation. 

  Do not connect wires to unused terminals as this will interfere with proper operation of the 

instrument. 

  Turn off the power supply before cleaning the instrument. 

  Do not use a volatile solvent such as paint thinner to clean the instrument. Deformation or 

discoloration may occur. Use a soft, dry cloth to remove stains from the instrument. 

  Do not connect modular connectors to telephone line. 

 

NOTICE 

  This manual assumes that the reader has a fundamental knowledge of the principles of 

electricity, process control, computer technology and communications. 

 The figures, diagrams and numeric values used in this manual are only for explanation 

purpose. 

  RKC is not responsible for any damage or injury that is caused as a result of using this 

instrument, instrument failure or indirect damage. 

  RKC is not responsible for any damage and/or injury resulting from the use of instruments 

made by imitating this instrument. 

  Periodic maintenance is required for safe and proper operation of this instrument. Some 

components have a limited service life, or characteristics that change over time. 

  Every effort has been made to ensure accuracy of all information contained herein. RKC 

makes no warranty, expressed or implied, with respect to the accuracy of the information. The 
information in this manual is subject to change without prior notice. 

  No portion of this document may be reprinted, modified, copied, transmitted, digitized, stored, 

processed or retrieved through any mechanical, electronic, optical or other means without 
prior written approval from RKC. 

 

1. OUTLINE 

COM-ML-1 [For SRZ] (hereafter called COM-ML) is communication converter to connect the RKC module 
type controller SRZ to the Ethernet [Modbus/TCP or PLC communication (MAPMAN)]. Multi-zone 
temperature control system can be easily achieved by connecting functional modules (Z-TIO, Z-DIO 
and Z-CT modules) of SRZ to COM-ML. Host communication (RKC communication, Modbus) is also 
possible. The combination of COM-ML and functional module of SRZ is called an SRZ unit. 

 

 

2. PARTS DESCRIPTION 

 

Mainframe 

 

Indication lamp 

FAIL/RUN 
 [Green 

or 

Red] 

 When normal: 

A green lamp is on (RUN) 

 During setting of default IP address setting: A green lamp flashes (RUN)

 Self-diagnostic error (Recoverable fault):  A green lamp flashes (FAIL)

 Self-diagnostic error (Major fault): 

A red lamp is on (FAIL) 

RX/TX 

[Green]  During host communication data send and receive:  Turns on 

NS (Network status) 
 [Green 

or 

Red] 

 No power or no IP address: 

Turns off 

 In Process Active or Idle state: 

A green lamp is on 

  (The green lamp flashes during the PLC communication) 

 Waiting for connection: 

A green lamp flashes 

 Duplicate IP address, or FATAL error: 

A red lamp is on

 

 Process Active Timeout: 

A red lamp flashes 

Link/Activity  
(Port 1/Port 2) 
 [Green 

and 

Yellow] 

 No link, no activity: 

Turns off 

 Link established, 100 Mbps: 

A green lamp is on 

 Activity, 100 Mbps: 

A green lamp flickering 

 Link established, 10 Mbps: 

A yellow lamp is on 

 Activity, 10 Mbps: 

A yellow lamp flickering 

MS (Module status) 
 [Green 

or 

Red] 

 No power: 

Turns off 

 Normal operation: 

A green lamp is on 

 Major fault: 

A red lamp is on 

 Recoverable fault: 

A red lamp flashes 

 

Communication port (modular connector) and communication connector 

COM. PORT 

Use to connecting the Operation panel or Host computer. 
 [RS-485 

or 

RS-422A] 

Loader communication 
connector 

Use to connecting the communication converter and personal computer 
when loader communication is performed. 

Ethernet connector 
(Port 1/Port 2) 

Use to connecting the Ethernet. 

 

Switch 

Host communication 
address setting switch 

Sets unit address for host communication. 

DIP switch 

 Sets communication speed and communication protocol corresponding 

to host communication. 

 Sets DIP switch setting validity/invalidity. 

 Sets the default IP address settings. 

 

 

Base

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

3. MOUNTING 

 
 
 
 
 
 
 
 

3.1 Mounting Cautions 

(1)  Use this instrument within the following ambient temperature and ambient humidity. 

 Allowable ambient temperature: 

10 to 

50 

 Allowable ambient humidity:   

5 to 95 %RH   

 

(Absolute humidity: MAX. W. C 29.3 g/m

3

 dry air at 101.3 kPa) 

 Installation environment conditions:  Indoor use,   

 

Altitude up to 2000 m 

 
(2)  Avoid the following conditions when selecting the mounting location: 

  Rapid changes in ambient temperature which may cause condensation. 

  Corrosive or inflammable gases. 

  Direct vibration or shock to the mainframe. 

  Water, oil, chemicals, vapor or steam splashes. 

  Excessive dust, salt or iron particles. 

  Excessive induction noise, static electricity, magnetic fields or noise. 

  Direct air flow from an air conditioner. 

  Exposure to direct sunlight. 

  Excessive heat accumulation. 

 
(3)  Mount this instrument in the panel considering the following conditions: 

  Provide adequate ventilation space so that heat does not build up. 

  Ensure at least 50 mm space on top and bottom of the instrument for maintenance and 

environmental reasons. 

  Do not mount this instrument directly above the equipment that generates large amount of heat 

(heaters, transformers, semi-conductor functional devices, large-wattage resistors.) 

  If the ambient temperature rises above 50 

C, cool this instrument with a forced air fan, cooler, or 

the like. Cooled air should not blow directly on this instrument. 

  In order to improve safety and the immunity to withstand noise, mount this instrument as far away 

as possible from high voltage equipment, power lines, and rotating machinery. 

High voltage equipment:  Do not mount within the same panel. 
Power lines: 

Separate at least 200 mm. 

Rotating machinery: 

Separate as far as possible. 

  For correct functioning mount this instrument in a horizontal position.   

  Be sure the COM-ML and function modules are joined when using them. 

 

Top

Bottom

 

(4)  If this instrument is permanently connected to equipment, it is important to include a switch or 

circuit-breaker into the installation. This should be in close proximity to the equipment and within 
easy reach of the operator. It should be marked as the disconnecting device for the equipment. 

 

 

3.2 Joining Each Module 

Before joining the COM-ML and function modules, use the DIP switch to make the 
communication settings. For the setting procedure, refer to COM-ML-1 [For SRZ] 
Quick Instruction Manual (IMR02E14-E

). 

 

The maximum number of function modules (Z-TIO, Z-DIO and Z-CT) described in the following can 
be joined per COM-ML. For details on joining function modules with the COM-ML, refer to the 

Z-TIO 

INSTRUCTION MANUAL (IMS01T01-E

)

  When joining function modules of the same type: 

Up to 16 modules 

  When joining function modules of two or more different types: Up to 30 modules   

(However, the maximum joinable number of function modules of the same type is 16.) 

[Example] When the Z-TIO-A/B and Z-DIO-A modules are joined 

 

SRZ unit

16 Z-TIO-A/B modules

COM-ML

Function modules: Up to 30 modules

14 Z-DIO-A modules





 

When the number of correspondence channels is specified using the model code, only the 
amount of data corresponding to the specified number of channels can be sent or received. 
(PLC communication specification only) 

The number of the 

correspondence channels

Z-TIO module 

Z-DIO module 

64 channels 

64 channels

(Up to 16 modules) * 

128 channels 

(Up to 16 modules) * 

48 channels 

48 channels

(Up to 12 modules) * 

96 channels 

(Up to 12 modules) * 

32 channels 

32 channels

(Up to 8 modules) * 

64 channels 

(Up to 8 modules) * 

16 channels 

16 channels

(Up to 4 modules) * 

32 channels 

(Up to 4 modules) * 

*

 

The number indicated in parentheses is the maximum joinable number per module when 

the indicated number of correspondence channels is specified. The amount of data that 
can be sent or received does not increase even when modules exceeding the maximum 
number are joined. 

 

3.3 Dimensions 

 

76.9 

30 6.7

10

0

 

4.7

(Unit: mm)

 

  

 

 

 

 

Procedure for mounting or removing 

The procedure for mounting or removing the COM-ML is the same as that of the function module 
(Z-TIO, Z-DIO or Z-CT). Both DIN rail mounting and screw mounting are available. 
For the mounting or removing, refer to the 

Z-TIO INSTRUCTION MANUAL (IMS01T01-E

)

 
 

4. WIRING 

 

 
 
 
 
 
 
 

 

4.1 Wiring Cautions 

 To avoid noise induction, keep communication signal wire away from instrument power line, 

load lines and power lines of other electric equipment. 

 If there is electrical noise in the vicinity of the instrument that could affect operation, use a noise 

filter. 

 Shorten the distance between the twisted power supply wire pitches to achieve the most 

effective noise reduction. 

 Always install the noise filter on a grounded panel. Minimize the wiring distance between 

the noise filter output and the instrument power supply terminals to achieve the most 
effective noise reduction. 

 Do not connect fuses or switches to the noise filter output wiring as this will reduce the 

effectiveness of the noise filter. 

  Power supply wiring must be twisted and have a low voltage drop. 

  For an instrument with 24 V power supply input, supply power from “SELV” circuit defined as 

IEC 60950-1. 

  A suitable power supply should be considered in the end-use equipment. 

The power supply must be in compliance with a limited-energy circuits (maximum available 
current of 8 A). 

 Supply the power to only one of the joined modules. When power is supplied to any one of 

the joined modules, all of the joined modules will receive power. 

 Select the power capacity which is appropriate for the total power consumption of all joined 

modules (including COM-ML) and the initial current surge when the power is turned on.   
Power consumption (at maximum load):  120 mA max. (at 24 V DC) 
 

Rush current: 12 A or less 

 When connecting the wiring to the terminals on the base, use the specified solderless 

terminals. Only these specified solderless terminals can be used due to the insulation 
between the terminals. 
Screw Size: 

Power supply terminals:  M3 

 7 (with 5.8 

 5.8 square washer) 

Recommended tightening torque: 0.4 N

m (4 kgf

cm) 

Applicable wire:  Solid/twisted wire of 0.25 to 1.65 mm

2

 

Specified solderless terminal: 
 

Manufactured by J.S.T MFG CO., LTD. 

 

Circular terminal with isolation V1.25

MS3 

 

(M3 screw, width 5.5 mm, hole diameter 3.2 mm) 

  Make sure that during field wiring parts of conductors cannot 

come into contact with adjacent conductive parts. 

 

 

4.2 Terminal Configuration 

3 4  5 

1

2

24 V DC

+

Power supply 
terminals 

Supply the power to only one of the joined 
modules or COM-ML.   
When power is supplied to any one of the 
joined modules or COM-ML, all of the joined 
modules and COM-ML will receive power. 

Terminals 3, 4 and 5
(Usage is prohibited.) 

Lower part of the base 

 

(Unit: mm)

50 mm or more

 Depth for communication cables 

mounting 

Space for communication cables must 
be considered when installing 

  Space required between each 

module vertically 

When the module is mounted on the
panel, allow a minimum of 50 mm at the
top and bottom of the module to attach
the module to the mainframe. 

Communication cable 

Approx. 50

76.9 

Loader 
communication 
connector 

Indication lamp RX/TX 

Indication lamp FAIL/RUN 

Host communication 
address setting switch 

Communication port
COM. PORT 

Indication lamp Link/Activity (Port 1)

Ethernet connector 
(Port 1)   

Left side view 

DIP switch 

Front view 

Indication lamp MS

 

Indication lamp NS

 

Indication lamp Link/Activity (Port 2)

Ethernet connector 
(Port 2)

 

COM-ML 

FAIL/RUN 

LO

AD

E

R

 

RX/TX 

NS

M

S

M

O

DB
US
/T

CP
 

Ethernet 

Ethernet 

Communication Converter 

COM-ML-1 

SRZ unit 

Host 
computer 

Z-TIO, Z-DIO and Z-CT modules

RKC communication 

Modbus 

RS-485 

RS-422A 

COM-ML-1 [For SRZ] Installation Manual (IMR02E13-E

) .................................................. 1 

COM-ML-1 [For SRZ] Quick Operation Manual (IMR02E14-E

)......................................... 1 

COM-ML-1 [For SRZ] Host Communication Data List (IMR02E15-E

) .............................. 1 

COM-ML-1 [For SRZ] PLC Communication Data List (IMR02E16-E

) ...............................  1 

All Rights Reserved, Copyright 

 2018, RKC INSTRUMENT INC. 

COM-ML-1

 

Installation

Manual

[For SRZ] 

 

To prevent electric shock or instrument failure, always turn off the power 
before mounting or removing the instrument. 

 
 

To prevent electric shock or instrument failure, do not turn on the power 
until all the wiring is completed. Make sure that the wiring has been 
properly made before applying power to the instrument. 

 5.5 MAX

 3.2 MIN 

9.0 mm

5.6 mm

 5.0

For detailed handling procedures and various function settings, refer to 
separate 

COM-ML-1 [For SRJ] Instruction Manual (IMR02E17-E

)

.  

The manual can be downloaded from the official RKC website:   
http://www.rkcinst.com/english/manual_load.htm 

Joint connector 

Used to mechanically and 
electrically connect   
each function module. 

Power supply terminals 

These are terminals to supply 
power to the COM-ML and
joined function modules. 

Terminal 3, 4 and 5 

These terminals cannot be 
used for the COM-ML. 
(Usage is prohibited.) 

Mounting bracket 

Used to fix the COM-ML on   
DIN rails. 

Mounting holes (M3 screw) 

Holes for screws to fix the base
to a panel, etc. 
Customer must provide the M3
screws. 

1 2 

3 4 5 

 

 To prevent injury to persons, damage to the instrument and the 

equipment, a suitable external protection device shall be required. 

 All wiring must be completed before power is turned on to prevent 

electric shock, fire or damage to the instrument and the equipment. 

 This instrument must be used in accordance with the specifications to 

prevent fire or damage to the instrument and the equipment. 

 This instrument is not intended for use in locations subject to flammable 

or explosive gases. 

 Do not touch high-voltage connections such as power supply terminals, 

etc. to avoid electric shock. 

 RKC is not responsible if this instrument is repaired, modified or 

disassembled by other than factory-approved personnel. Malfunction 
may occur and warranty is void under these conditions. 

Отзывы: