![RK Rose+Krieger RK MultiControl II duo Скачать руководство пользователя страница 217](http://html1.mh-extra.com/html/rk-rose-krieger/rk-multicontrol-ii-duo/rk-multicontrol-ii-duo_assembly-instructions-manual_1466556217.webp)
Interval
Maintenance work
Personnel
Weekly
Check the hand switch for soiling. If necessary, clean the hand
switch with a clean cloth.
Important:
Do not use cleaning agents containing solvents!
Assembly staff
Monthly
Check the electrical connections between the control unit and the
drives for mechanical stress and to make sure they are firmly in
place.
Qualified electrician
Once a year
Carry out a safety inspection of the control unit as per DGUV V3.
Qualified electrician
8.3 Troubleshooting
Error messages are displayed on the display screen of the hand
switch with a error code (e.g.
“E21”
).
The error code can also be signalled in code by the LED display of
the hand switches.
Example error code “E21” :
Long pause
®
2x flash
®
Pause
®
1xflash
®
long paws
(repeat)
Further information:
n
“Table of error messages” on page 217
To reset the error message, press the function key .
To reset the error message, press and hold both function keys
for 5 s.
Code Description
Troubleshooting
“E2”
Error, drive 1 motor current too
high
If the error occurs frequently, check the system for mechanical
overload.
“E3”
Error, drive 2 motor current too
high
Maintenance plan
Error messages
Resetting error messages
Table of error messages
Maintenance and troubleshooting
Troubleshooting
20.08.2021
Control unit RK MultiControl II duo/RK MultiControl II quadro
217
Содержание RK MultiControl II duo
Страница 115: ...Anhang Anhang 20 08 2021 Steuerung RK MultiControl II duo RK MultiControl II quadro 115...
Страница 116: ...Anhang 20 08 2021 Steuerung RK MultiControl II duo RK MultiControl II quadro 116...
Страница 228: ...Appendix Appendix 20 08 2021 Control unit RK MultiControl II duo RK MultiControl II quadro 228...