Lynx™ Shielded Dual‑Relay Output Module OR2‑M | Product Manual
2
RJG, Inc.
OPERATION
PART SORTING OUTPUTS
The OR2‑M is often used to provide a signal
to sorting equipment to perform sorting
actions. The shielded dual‑relay input module
cable C‑OR2‑M‑3M is wired to the sorting
equipment input card which accepts the signal;
the C‑OR2‑M‑3M is connected to the OR2‑M,
which collects the signal for use from the
eDART
.
In the
eDART
software, the module is configured
to properly identify and sort parts; the module
may also be configured to stop the machine
after a specified number of reject parts are
created in a specified number of consecutive
cycles.
1.
Good Control
Good control sends a signal to a robot that the
last part made is “good” for sorting purposes.
2.
Sample Parts Control
Sample parts control turns on a “sample parts”
control—could be used to tell a robot to divert
parts to a special sample location.
3.
Excessive Rejects Control
Excessive rejects control turns on “excessive
rejects” control based on a user‑defined number
of rejects within a user‑defined number of
consecutive cycles; the output signal could turn
on some form of an alerting mechanism or it
could shut the machine down entirely.
4.
Bad/Reject Control
Bad, or reject, control sends a signal to a robot
that the last part made was “bad” for sorting
purposes.
CONTROL OUTPUTS
1.
Injection Enable
The OR2‑M is often used to provide a signal to
the injection molding machine to indicate the
machine that injection is enabled. The shielded
dual‑relay input module cable C‑OR2‑M‑3M is
wired to the machine input card which accepts
the signal; the C‑OR2‑M‑3M is connected to
the OR2‑M, which collects the signal for use
from the
eDART
. In the
eDART
software, the
module is configured to properly detect and
enable injection.
2.
Machine Transfer
The OR2‑M is often used to provide a signal
to the injection molding machine to indicate
the machine to transfer from pressure to
hold (V
→
P). The shielded dual‑relay output
module cable C‑OR2‑M‑3M is wired to the
machine input card which accepts the signal;
the C‑OR2‑M‑3M is connected to the OR2‑M,
which collects the signal for use from the
eDART
. In the
eDART
software, the module is
configured to properly detect and enable V
→
P.
3.
Job Start
The OR2‑M can be used in conjunction
with the
eDART
Job Started tool to allow
a machine to run only after the
eDART
job
is running. The shielded dual‑relay output
module cable C‑OR2‑M‑3M is wired to the
machine input card, which accepts the signal;
the C‑OR2‑M‑3M is connected to the OR2‑M,
which collects the signal for use from the
eDART
when the specified job is running.
Содержание Lynx OR2-M
Страница 2: ...PRINT DATE 11 11 2019 REVISION NO 1 ...
Страница 6: ...Lynx Shielded Dual Relay Output Module OR2 M Product Manual iv RJG Inc ...
Страница 8: ...Lynx Shielded Dual Relay Output Module OR2 M Product Manual vi RJG Inc ...
Страница 14: ...Lynx Shielded Dual Relay Output Module OR2 M Product Manual 6 RJG Inc ...
Страница 18: ...Lynx Shielded Dual Relay Output Module OR2 M Product Manual 10 RJG Inc ...
Страница 33: ......