Product Manual | Lynx™ Shielded Analog Input Module IA1‑M‑V
RJG, Inc.
1
PRODUCT DESCRIPTION
The Lynx™ shielded analog input module
IA1‑M‑V is a DIN‑rail‑mounted module that
is wired to the molding machine in order
to collect 0–10 V DC signals from analog
measurement devices, providing information
such as injection pressure, plastic pressure,
screw position, and temperature.
APPLICATIONS
PROCESS MONITORING AND CONTROL
The IA1‑M‑V gathers 0–10 V signals from
molding machine analog inputs for the
eDART
.
The
eDART
performs computations using the
0–10 V DC signals from the injection molding
machine or other measurement devices for
various process parameters during a typical
cycle.
OPERATION
The IA1‑M‑V supplies the
eDART
with injection
pressure, stroke position/velocity, or dew point
signals from the machine’s output card.
In addition, the IA1‑M‑V is compatible with
other measurement devices that supply a
0–10 V signal for process monitoring, including:
air flow, barrel temperature, coolant flow
rate, coolant pressure, coolant temperature,
delta pressure, dryer temperature, ejector pin
(indirect) pressure, hydraulic pressure, line
temperature, melt pressure, mold deflection,
mold temperature, power consumption,
revolution rate, and vacuum.
INJECTION PRESSURE
The IA1‑M‑V is often used to acquire an
injection pressure signal from electric injection
molding machines. The shielded analog input
module cable C‑IA1‑M‑3M is wired to the
machine output card which provides the signal;
the C‑IA1‑M‑3M is connected to the IA1‑M‑V,
which collects the signal for use with the
eDART
.
In the
eDART
software, the module is configured
to read the voltages as pressures.
SCREW POSITION/VELOCITY
The IA1‑M‑V is often used to acquire an screw
position/velocity signal from electric injection
molding machines. The shielded analog input
module cable C‑IA1‑M‑3M is wired to the
machine output card which provides the signal;
the C‑IA1‑M‑3M is connected to the IA1‑M‑V,
which collects the signal for use with the
eDART
.
In the
eDART
software, the module is configured
to read the voltages as position/velocity.
DEW POINT
The IA1‑M‑V can be used to acquire a dew
point measurement from the Vaisala DRYCAP
®
Transmitters DMT142 or DMT143. The
DMT142 or DMT143 is connected to the
IA1‑M‑V using a cable (included with DMT142
or DMT143 purchase from RJG), which collects
the signal for use with the
eDART
. In the
eDART
software, the module is configured to read the
voltages as dew point.
Содержание Lynx IA1-M-V
Страница 1: ...PRODUCT MANUAL Training and Technology for Injection Molding Lynx Shielded Analog Input Module IA1 M V...
Страница 2: ...PRINT DATE 02 25 2019 REVISION NO 0...
Страница 6: ...Lynx Shielded Analog Input Module IA1 M V Product Manual iv RJG Inc...
Страница 10: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 4 RJG Inc...
Страница 16: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 10 RJG Inc...
Страница 21: ......