background image

Product Manual | Lynx™ Shielded Analog Input Module IA1‑M‑V

RJG, Inc.

1

PRODUCT DESCRIPTION

The Lynx™ shielded analog input module 
IA1‑M‑V is a DIN‑rail‑mounted module that 
is wired to the molding machine in order 
to collect 0–10 V DC signals from analog 
measurement devices, providing information 
such as injection pressure, plastic pressure, 
screw position, and temperature. 

APPLICATIONS

PROCESS MONITORING AND CONTROL

The IA1‑M‑V gathers 0–10 V signals from 
molding machine analog inputs for the 

eDART

The 

eDART

 performs computations using the 

0–10 V DC signals from the injection molding 
machine or other measurement devices for 
various process parameters during a typical 
cycle.  

OPERATION

The IA1‑M‑V supplies the 

eDART

 with injection 

pressure, stroke position/velocity, or dew point 
signals from the machine’s output card. 

In addition, the IA1‑M‑V is compatible with 
other measurement devices that supply a 
0–10 V signal for process monitoring, including: 
air flow, barrel temperature, coolant flow 
rate, coolant pressure, coolant temperature, 
delta pressure, dryer temperature, ejector pin 
(indirect) pressure, hydraulic pressure, line 
temperature, melt pressure, mold deflection, 
mold temperature, power consumption, 
revolution rate, and vacuum.

INJECTION PRESSURE

The IA1‑M‑V is often used to acquire an 
injection pressure signal from electric injection 
molding machines. The shielded analog input 
module cable C‑IA1‑M‑3M is wired to the 
machine output card which provides the signal; 
the C‑IA1‑M‑3M is connected to the IA1‑M‑V, 
which collects the signal for use with the 

eDART

In the 

eDART

 software, the module is configured 

to read the voltages as pressures.

SCREW POSITION/VELOCITY

The IA1‑M‑V is often used to acquire an screw 
position/velocity signal from electric injection 
molding machines. The shielded analog input 
module cable C‑IA1‑M‑3M is wired to the 
machine output card which provides the signal; 
the C‑IA1‑M‑3M is connected to the IA1‑M‑V, 
which collects the signal for use with the 

eDART

In the 

eDART

 software, the module is configured 

to read the voltages as position/velocity.

DEW POINT

The IA1‑M‑V can be used to acquire a dew 
point measurement from the Vaisala DRYCAP

®

 

Transmitters DMT142 or DMT143. The 
DMT142 or DMT143 is connected to the 
IA1‑M‑V using a cable (included with DMT142 
or DMT143 purchase from RJG), which collects 
the signal for use with the 

eDART

. In the 

eDART

 

software, the module is configured to read the 
voltages as dew point.

Содержание Lynx IA1-M-V

Страница 1: ...PRODUCT MANUAL Training and Technology for Injection Molding Lynx Shielded Analog Input Module IA1 M V...

Страница 2: ...PRINT DATE 02 25 2019 REVISION NO 0...

Страница 3: ...S 1 PROCESS MONITORING AND CONTROL 1 OPERATION 1 INJECTION PRESSURE 1 SCREW POSITION VELOCITY 1 DEW POINT 1 OTHER SUPPORTED SENSOR TYPES 2 DIMENSIONS 3 CABLE LENGTH 3 INSTALLATION INSTALLATION OVERVIE...

Страница 4: ...RT ON PRESS POWER UP 11 INCORRECT INJECTION PRESSURE SCALING 11 CUSTOMER SUPPORT 12 RELATED PRODUCTS COMPATIBLE PRODUCTS 13 SHIELDED ANALOG INPUT MODULE CABLE C IA1 M 3M 13 LYNX SHIELDED SEQUENCE MODU...

Страница 5: ...ed uses of the material or designs described herein are not to be construed as constituting a license under any RJG Inc patent covering such use or as recommendations for use of such material or desig...

Страница 6: ...Lynx Shielded Analog Input Module IA1 M V Product Manual iv RJG Inc...

Страница 7: ...ne temperature melt pressure mold deflection mold temperature power consumption revolution rate and vacuum INJECTION PRESSURE The IA1 M V is often used to acquire an injection pressure signal from ele...

Страница 8: ...also supports the additional following sensor types Ejector Pin indirect Hydraulic Pressure Mold Temperature Barrel Temperature Coolant Temperature Coolant Flow Rate Delta Pressure Revolution Rate OPE...

Страница 9: ...Product Manual Lynx Shielded Analog Input Module IA1 M V RJG Inc 3 DIMENSIONS CABLE LENGTH CABLE LENGTH The C IA1 M 3M is 9 8 ft 3 m long...

Страница 10: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 4 RJG Inc...

Страница 11: ...output card on one end or to some other 0 10 V measurement device and connected to the IA1 M V on the other using the four pin connector The shielded analog input module is connected to the ID7 M SEQ...

Страница 12: ...ust be located away from any static sources such as feeder tubes and material hoppers WIRING The C IA1 M 3M cable has colored coded wires to simplify installation Refer to the table below for the corr...

Страница 13: ...ould be displayed in the Value column Record the machine value for the measurement at this time as well For example if using the IA1 M V to acquire injection pressure from the machine record the machi...

Страница 14: ...er 5 Enter the machine value recorded in step 4 into the Maximum field and select the appropriate units of measurement 6 Enter the maximum voltage recorded in step 4 into the Voltage at Maximum Pressu...

Страница 15: ...and robustness of the shielded analog input module and so are offering a one year warranty RJG s products are guaranteed against defects in material and workmanship for one year from the original dat...

Страница 16: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 10 RJG Inc...

Страница 17: ...s started before machine is powered on Solution Always power the eDART on after the machine is powered on Analog signals tend have a spike or a sudden lurch from zero to a specific position voltage Of...

Страница 18: ...Analog Input Module IA1 M V Product Manual 12 RJG Inc CUSTOMER SUPPORT Contact RJG s Customer Support team by phone or email RJG Inc Customer Support P 800 472 0566 Toll Free P 1 231 933 8170 www rjgi...

Страница 19: ...ART System the C IA1 M 3M provides a connection from molding machines output card and the RJG Inc C IA1 M 3M LYNX SHIELDED SEQUENCE MODULE ID7 M SEQ The Lynx shielded sequence module ID7 M SEQ 2 at ri...

Страница 20: ...YNX SHIELDED DUAL RELAY OUTPUT MODULE OR2 M The Lynx shielded dual relay output module OR2 M 2 at right is a shielded DIN rail mounted module that interfaces the eDART and sorting equipment or injecti...

Страница 21: ......

Страница 22: ...E A PTE LTD Singapore Republic of Singapore P 65 6846 1518 sales swg rjginc com en rjginc com FRANCE RJG FRANCE Arnithod France P 33 384 442 992 sales fr rjginc com fr rjginc com CHINA RJG CHINA Chen...

Отзывы: