Appendix

34

Step 4.

Hold the limit switch in place and use a ty-wrap to tighten 
it down to the tie-bar. See figure 29.
More than one ty-wrap can be tied together if the tie-bar is 
large.

              Figure 29:  Lynx™ Mold-Closed Limit Switch L-LS side view

Table 26: Figure Labels

Step 5.

Plug a Lynx™ cable between the limit switch and the 

eDART

 System™.

Step 6.

Run the machine to ensure proper use, while monitoring 
the 

eDART™

 software.

C

A

L-LS

B

D

A

Moving Half

B

Ejector Plate

C

Tie Bar

D

Tighten Ty-Wrap

U

Always power down before working on 
any equipment.