CABLE AND CASE ISSUES
CABLES
4. Sensor cable is pinched during mold
assembly (
1
at right).
5. Sensor case is mounted on surface that
exceeds temperature rating.
•
Do not mount the Lynx case on surface
that exceeds the recommended
temperature rating. Contact RJG, Inc.
Customer support for high‑temperature
applications.
SENSOR ADAPTER CASES
6. Sensor adapter case is drilled to
accommodate alternate mounting (
2
at
right).
•
NEVER drill a sensor adapter case.
Failure to comply will result in damage
or destruction to equipment and void of
warranty.
7. Orientation of Lynx connector on sensor
adapter case is altered from OEM (
3
at
right).
The Lynx connector on the sensor adapter
case is keyed. DO NOT attempt to change
key orientation by loosening or tightening
the Lynx connector on the sensor adapter
case. Failure to comply will result in
damage to equipment and void of warranty.