RJE ULB-362/18 Скачать руководство пользователя страница 14

ULB-362B Underwater Locator Beacon   

 

 

 

 

 

 

        

10

 

 

 

User’s Manual 

January 2018

 

 

Beacon Maintenance

 

This section covers the cleaning, recommended testing interval, disposal, 
storage procedures, and battery replacement for the ULB-362B Series 
Underwater Locator Beacons. 
 
 

Beacon Cleaning 

 
 

The end cap with the water switch should remain free and clear of dirt, 
grease, and dust. The beacon should be cleaned with a mild detergent and 
dried thoroughly with a clean cloth. This process should be repeated 
periodically depending on the local environment. 

 

Beacon Maintenance Precautions 

 
 

The following precautions should be exercised when handling or storing the 
beacon: 

 

 

The beacon should not be exposed to temperatures in excess of 
71ºC (160ºF), as the battery life can be reduced by storage in a high 
temperature environment.

 

 

 

Any situation that could possibly crush or penetrate the case of the 
beacon should be avoided.

 

 

Battery Maintenance 

 
 

The shelf life on the ULB-362B beacon is six (6) years. The standard 
operational life of the beacon is thirty (30) days of continuous use and it is 
recommended that the battery be replaced after every deployment.   

 
  

When deploying an ULB-362PL/37 power loss beacon on a vehicle, replace 
the battery on or before the date stamped on the beacon label. 

 
 

When replacing the battery on ULB-362B beacon, please follow the chart 
below for selecting the proper Battery Kit. 

 
 
 

Содержание ULB-362/18

Страница 1: ...ator Beacon User s Manual January 2018 P N 362 17001 A RJE INTERNATIONAL INC 15375 Barranca Parkway Suite I 112 Irvine California 92618 U S A www rjeint com Tel 1 949 727 9399 Fax 1 949 727 0070 e mai...

Страница 2: ...RJE International Inc Materials may not be reproduced or disseminated without the prior written consent of RJE International Inc Changes RJE International Inc reserves the right to make changes to mee...

Страница 3: ...ion and Checkout 5 Installation Considerations 5 Installation Procedures for ULB 362B and ULB362 02 Mounting Bracket 6 Installation Procedures for ULB 362 PL 8 Pre Deployment Tests 9 Battery Check 9 4...

Страница 4: ...1 2 Installed in Mounting Bracket 2 Figure 1 3 Dimensions 2 Figure 1 4 Locating the ULB 362B After Water Activation 3 Figure 3 1 Mounting Bracket Hole Pattern 6 Figure 3 2 Securing the Mounting Bracke...

Страница 5: ...z and 45kHz The beacons transmit an acoustic signal once every second after activation The acoustic output for the 30 day battery will remain above 157 0dB for 30 days RJE International Inc also offer...

Страница 6: ...uction The beacon is contained in a water tight aluminum case capable of withstanding high impact shock and deep water immersion As shown in Figure 1 2 one of the end caps has a built in water activat...

Страница 7: ...h the housing in the form of a tuned acoustic signal based on the frequency of the beacon 27kHz 37 5kHz or 45kHz Locating the Beacon When the beacon is immersed in water it will begin to radiate an ac...

Страница 8: ...s 6 years from date of manufacture Battery Storage Life in Beacon 6 years from date of manufacture 160 5 dB re 1 Pa 1 meter Acoustic Output 160 5 dB re 1 Pa 1 meter Water immersion Activation Water im...

Страница 9: ...sturdy structure without weakening the structure itself The beacon should be mounted in an area guarded against heavy equipment tearing loose and striking the beacon and should be mounted in a way th...

Страница 10: ...rform the following steps 1 Ensure the beacon is mounted in the vehicle so that it has a clear path to send the acoustic signal Avoid mounted it behind other equipment 2 Mount the beacon with the wate...

Страница 11: ...ULB 362B Underwater Locator Beacon 7 User s Manual January 2018 Figure 3 2 Securing the Mounting Bracket Figure 3 3 Installing the Beacon into the Mounting Bracket...

Страница 12: ...beacon is mounted in the vehicle so that it has a clear path to send the acoustic signal Avoid mounting it behind other equipment 2 Mount the beacon with the water switch down to prevent accidental a...

Страница 13: ...beacon Battery Check A high impedance minimum input impedance of 10 Megohms digital voltmeter can be used to measure the battery voltage Use the following procedure to measure the battery voltage 1 Pl...

Страница 14: ...ns should be exercised when handling or storing the beacon The beacon should not be exposed to temperatures in excess of 71 C 160 F as the battery life can be reduced by storage in a high temperature...

Страница 15: ...User s Manual first If the battery voltage is 6 0 volts or more remove the battery and dispose of the battery and beacon in accordance with local regulations If the battery voltage is less than 6 0 v...

Страница 16: ...International Inc for a Case Number and shipping instructions RJE International Inc Tel 1 949 727 9399 Fax 1 949 727 0070 e mail sales rjeint com You will need to provide the following information to...

Страница 17: ...OR FOR LOST OR CORRUPTED DATA LOSS OF BUSINESS LOSS OF PROFITS LOSS OF USE OF THE PRODUCT OR ANY ASSOCIATED EQUIPMENT COST OF CAPITAL COST OF SUBSTITUTE OR REPLACEMENT PRODUCT FACILITIES OR SERVICES...

Отзывы: