ULB-362B Underwater Locator Beacon
10
User’s Manual
January 2018
4
Beacon Maintenance
This section covers the cleaning, recommended testing interval, disposal,
storage procedures, and battery replacement for the ULB-362B Series
Underwater Locator Beacons.
Beacon Cleaning
The end cap with the water switch should remain free and clear of dirt,
grease, and dust. The beacon should be cleaned with a mild detergent and
dried thoroughly with a clean cloth. This process should be repeated
periodically depending on the local environment.
Beacon Maintenance Precautions
The following precautions should be exercised when handling or storing the
beacon:
▪
The beacon should not be exposed to temperatures in excess of
71ºC (160ºF), as the battery life can be reduced by storage in a high
temperature environment.
▪
Any situation that could possibly crush or penetrate the case of the
beacon should be avoided.
Battery Maintenance
The shelf life on the ULB-362B beacon is six (6) years. The standard
operational life of the beacon is thirty (30) days of continuous use and it is
recommended that the battery be replaced after every deployment.
When deploying an ULB-362PL/37 power loss beacon on a vehicle, replace
the battery on or before the date stamped on the beacon label.
When replacing the battery on ULB-362B beacon, please follow the chart
below for selecting the proper Battery Kit.