background image

PAGE 3

PAGE 2

Top Pivot Jamb Portion

Top Pivot Door Portion

Installation Instructions

1. Locating Closer

Spindle Position

2” From Face of
Jamb to C of Spindle

L

Door

Jamb

A. Measure 2” out from door jamb on centerline of door. This

is the location of the spindle center.

B. For threshold application: the closer case is set flush with

the finished floor.

C. CEMENT FLOOR INSTALLATION:

1. Set Cement case in floor and block in position.
2. Case should be parallel with centerline of door.
3. CEMENT CASE SHOULD BE LEVEL. Place levels per

illustration.

4. Grout in cement case with closer. Cement should not

get between closer and case.

D. WOOD FLOOR INSTALLATION:

1. Locate center line of closer 2" out from face of frame.

Using dimensioned outline of closer locate and bore (8)
3/4" diameter holes. Cut out the floor using these bored
holes and the dimensioned outline as a guide.

2. Place arm on spindle of closer

and set closer into opening, with
center of arm on line with center
of door. Draw a line around
overlapping square top of casting.
Mortise for this overlap allowing
1/16" for floor plate thickness. Top of closer case will be
1/16" below finished floor.

3. CLOSER CASE SHOULD BE LEVEL. Place levels per

illustration.

4. Fasten closer securely with screws furnished.
5. Place floor plate on closer, mark around it and mortise

into floor. Fasten with screws furnished.

A. Install top pivot in door per template.

B.

Install top pivot in jamb per template.

C. Centerline of pivot should line up with centerline of

closer. Use a plumb line to assure accuracy.

D. Mortise door to receive arm. (Mortise varies if

threshold is used–refer to template).

E. Secure bushing to bottom of door with screw

furnished.

F.

Drill two 5/8" holes for alignment screws.

4. Hang Door

Pin Retracting

Screw

Top Pivot

Pin

Centerline of Door
and Spindle

3. Install Top Pivot and Closer Arm

Alignment Screws

Bushing (X)

Centerline

of Door

30°

Alignment Screws

Adjusting Screw

A. Turn valve screw down. NEVER FORCE VALVE

SCREW DOWN AS THIS WILL DAMAGE TIP
SEATING.

B. Fasten arm to closer spindle then turn spindle right

(or left) until spindle and arm reach a door opening
position of about 30°.

C. Set door on arm and engage the top pivot pin by

turning pin retracting screw up.

D. Turn in arm alignment screws lightly.

E. Open stroke valve (counter-clockwise) one turn.

F.

Adjust

door rests in

center of doorway.

arm alignment screws until

Face of Jamb

1-3/32

2-3/16

1-9/16

2"

2-5/8

Center

of Spindle

1-9/16

3-1/8

15/16

1-7/8

6-1/8

Center

line

Betw

een J

a

mbs

1-5/8

13/16

3/4 Dia. Typ.

WARNING:

Do not strike closer with a hammer. The closer

can be made completely inoperative by denting the closer
tube with a hammer blow.

DOOR MUST NOT BE PERMITTED TO OPEN BEYOND
105°.

2. Install Closer in Floor

LEVEL IN BOTH

DIRECTIONS

A. For floor plate application: the top of the closer case (or

cement case as both are the same level) is set 1/16"
below finished floor.

Door Bushing (x)

Spindle

to C of spindle
on C of door

L

L

Rixson Specialty Door Controls

www.rixson.com

866-474-9766 Technical Department

Rixson Specialty Door Controls

www.rixson.com

866-474-9766 Technical Department

Отзывы: