Rixen DR-20 series Скачать руководство пользователя страница 6

 

J. Operation of LCD display type (DR-20D/22D) 

1. Display Mode 
      Device

Set, tick Display function box 

The recording values will display in LCD continuously while recording (Display type 

only). User could press and hold        button for 5 seconds to turn off LCD display. 

Press        button again to turn on LCD display.   

2. None Display mode (Default) 

      Device

Set, NOT tick Display function box 

User could press        button to display the measurement value for 3 seconds even 

turn off the display function.   

 

K. Real Time Display 

Real-Time record mode only available when connected data logger to PC. 

1. The data logger (display type) will update the real-time value on PC synchronous. 

 

2. The data logger (display type) will show up blink

         

symbol if user unplugs the   

logger while processing real-time function. There are three ways to deal with it: 

2.1 Re-plug logger to docking station within 30 seconds to continue real-time 

function. 

2.2 Press        button within 30 seconds to stop real-time function instantly. 

2.3 The data logger will stop real-time function automatically if user unplug data   

logger from docking station over 30 seconds, 

 

 

L. LCD Display Flowchart 

1. DR-20D   

 

                                             
 

LCD Display of DR-20D described as below 

 

Condition 

Display content 

LCD Display 

Temperature/Max./ 

Min. value display 

Temperature value   

Maximum Temp. value   

Minimum Temp. value   

 

Temperature/Alarm 

value display 

Temperature value 

Hi.A of Temperature value 

Lo.A of Temperature value   

 

Temperature/Max./Min. Values   

 

Temperature Alarm Values

 

 

 

 

 

Содержание DR-20 series

Страница 1: ...ions in PC DFC 201U Kit includes the following accessories DFC 201U USB Docking station DR USB S USB Flash driver for software DR USB W USB computer interface cable DR 1 05M Software Ver 1 05 and User...

Страница 2: ...n endpoint D Display descriptions DR 20D 22D User could turn on off the LCD display function via software Please refer to DFC 201U Software Operation Manual Turn off LCD display function will help use...

Страница 3: ...tions please refer to DFC 201U Software Manual 1 Install software DFC 201U Ver1 05 1 1 Connect the USB flash drive to computer 1 2 Double click Setup on the USB contents screen to install DFC 201U sof...

Страница 4: ...t Setting the desired start parameters for your application To set start parameters Device Set 1 Sampling Rate 1 second to 24 hours available 2 Temperature Unit or 3 Location Register storage location...

Страница 5: ...box show up To avoid occurring any accident which is caused by wrong operation the logger can only be stopped via DFC 201U software As described below 4 Stop Recording Connect the logger to PC via DFC...

Страница 6: ...alue on PC synchronous 2 The data logger display type will show up blink symbol if user unplugs the logger while processing real time function There are three ways to deal with it 2 1 Re plug logger t...

Страница 7: ...dity Minimum value of Humidity Temp Max Min value display Temperature value Maximum value of Temp Minimum value of Temp Humidity Alarm value display Humidity value Hi A value of Humidity Lo A value of...

Страница 8: ...for a while then it will be restored to normal c In order to connect the Logger with computer the optional docking station DFC 201U kit is necessary d Do not press or stab to the breathable waterproo...

Страница 9: ...mory Battery capacity icon Sensor Precision semiconductor sensor Sample Rate 1 second to 24 hours Battery Life 10 years typical at 25 15 minute sampling rate and turn off the display alarm function Ma...

Отзывы: