Wiring:

Red

12VDC + (install fuse - not supplied - 10A)

Black

Ground

Yellow

Switched Output 12VDC max 5A

2x Blue

External temperature probe (no polarity), 
sensor is optional, insulate wires when not used

Specs:

Operating Voltage:

10V - 16V

Power consumption: 19mA max, 10mA standby (@ 12.3V)

Mounting: 

2x pems,  drill 1/4” or 6mm holes
Cable hole 1/2” or 13mm

Dimension:

87mm (W) x  70mm (H) x 13mm (H)

Mounting template:

Print template - verify that your printer did not scale the drawing