![Rixen Digital Heating Thermostat Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/rixen/digital-heating-thermostat/digital-heating-thermostat_manual_1466289002.webp)
Wiring:
Red
12VDC + (install fuse - not supplied - 10A)
Black
Ground
Yellow
Switched Output 12VDC max 5A
2x Blue
External temperature probe (no polarity),
sensor is optional, insulate wires when not used
Specs:
Operating Voltage:
10V - 16V
Power consumption: 19mA max, 10mA standby (@ 12.3V)
Mounting:
2x pems, drill 1/4” or 6mm holes
Cable hole 1/2” or 13mm
Dimension:
87mm (W) x 70mm (H) x 13mm (H)
Mounting template:
Print template - verify that your printer did not scale the drawing
Rixen Digital Heating Thermostat
Manual v1
6mm or 1/4” drill bit
6mm or 1/4” drill bit
13mm or 1/2” drill bit