background image

6

Installation and commissioning

2.2 

Final assembly of the equipment

- Check for threaded screw and pipe connectors       on the suction and pressure 

sides, between pumps and jets and tighten as necessary, as they could have 
loosened during transport.

- mount handles.
- Plug in jet inserts and lock them in.
- mount the jet holders.
- mount the bezels.
- the pumps should be connected by a local specialist company approved 

according to appropriate regulations (see circuit diagram, page 5).

2.3 

Commissioning

Commissioning should only be carried out when the pool is full. 
-  switch on the pumps by pressing the Pn button.
-  switch off the pumps by pressing the Pn button again.
   the functions neck shower, back massage, counter-current swimming system 

are selected by turning the corresponding jet insert. the corresponding

setting is confirmed by the jet insert latching lightly into place. to operate 

the jet inserts switch off the pump.

-  the power can be regulated by partially turning the jet insert.
-  air can be mixed into the counter-current swimming system by opening the 

air regulator of the corresponding jet stream.  all other jets are permanently 

supplied with air.

note:

the integrated water torrent of the rimini stair equipment is designed to be

clad with kerbstones (corresponding adhesive is enclosed). the rotatable 

jets do not regulate the individual functions in total isolation of one another.

the seals needed to achieve this would detract from the free movement when 

turning the jets. therefore a small stream of water will come out of all jets. the 

rotatable jet that feed the neck torrent is fitted with an additional injector that 

sucks water out of the neck shower. in this way, in the Jet function, there is 

always some air in the jet stream.

1

2

3

4

5

Water torrent in the "rimini" step 

equipment

detail counter-current swimming 

system

3

1

2

"rimini" equipment shaft

5

4

Содержание Fun Pak F4

Страница 1: ...Technical Information SB 13 09 09 Operating instructions Fun Pak F 4 Counter current and massage equipment...

Страница 2: ...n Pak Rimini Attractions and Functional overview page 9 3 4 Fun Pak Modena 370 Attractions and Functional overview page 10 3 5 Fun Pak Modena 660 Attractions and Functional overview page 11 3 6 Fun Pa...

Страница 3: ...k as a standard feature is delivered completely pre assembled in the pool For this the RivieraPool foundation shaft is required for the corresponding steps If due to lack of space or building reasons...

Страница 4: ...Our foundation shafts are fitted as standard with a shaft drain bonded connector d 50 Exception swimming pools with a shower tray or filtration equipment installed in the equipment shaft are additiona...

Страница 5: ...aerator and humidity switch Set humidity switch to 65 The aerator must also run in winter when the swimming pool is switched off 4 Before doing the classing lay the shaft cover Leave sufficient space...

Страница 6: ...nsert latching lightly into place To operate the jet inserts switch off the pump The power can be regulated by partially turning the jet insert Air can be mixed into the counter current swimming syste...

Страница 7: ...nt system can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are in their mid...

Страница 8: ...her attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are in their middle position turn left hand jet to the left Masterjet mass...

Страница 9: ...ets can be manually switched to 2 Microjet massage jets and a master jet in the seating area a floor geyser in the foot area optional around the seating step and a water torrent in the pool wall Pump...

Страница 10: ...tem can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are in their middle po...

Страница 11: ...counter current system can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are...

Страница 12: ...e counter current system can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets a...

Страница 13: ...unter current system can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are i...

Страница 14: ...ockwise and withdrawing them from the jet element Loosen the Z bracket of the counter current equipment and remove the jets Plug the overwintering stoppers delivered with the system into the base of t...

Страница 15: ...t opening of the jet bushing Attach the jet closers made from transparent PVC pipe and screw on the locking ring hand tighten While doing this ensure the diverter opening does not move in the process...

Страница 16: ...www pools de One of the leading German manufacturers of prefabricated swimming pools swimming pool technology and whirlpools Member of BSW...

Отзывы: