background image

 

 

ASSEMBLE

 

SIDE PANELS

 

8

 

SELECT:

 

 

2 x 1.875 m Side Wall Sheets (Angled)

 

2 x 1.905 m Side Wall Sheets (Angled)

 

2 x 1.935 m Side Wall Sheets (Angled)

 

2 x 1.965 m Side Wall Sheets (Angled)

 

2 x 2.022 m Top Plates (Red)

 

2 x 2.020 m Bottom Plates (Green)

 

96 x 30mm Galv Clouts

 

12 x Rivets

 

IMPORTANT—IF YOU CHOOSE TO RAISE YOUR TIMBER 

BASE PLATE –READ THE FOLLOWING;

 

 

For sheds with Raised Base Plate option only (see page 6), deduct 

30mm from measurement shown between Top and Bottom Plates on 
all wall panels, so cladding protrudes 20mm below bottom plate

.

 

BOTTOM PLATE

 

BOTTOM PLATE

 

BOTTOM PLATE

 

1827mm

 

1948mm

 

15mm

 

BOTTOM PLATE

 

1827mm

 

1948mm

 

Second Side

 

Panel

 

STEP 1:

 

 

• 

Lay out 1 x Top Plate and 1 x Bottom Plate on a flat surface (corner 
cutouts to face as shown). 

Measurements between Top and Bottom 

plates are critical to ensure wall panels fit together.

 

STEP 2:

 

 

• 

Place 1 x 1.875m, 1 x 1.905m, 1 x 1.935m and 1 x 1.965m Side 
wall sheets on top of timber plates, with bottom of sheets flush 
with each other. 

 

• 

Rivet sheets together on overlaps as shown.

 

STEP 3:

 

 

• 

Nail wall sheets to the Top Plate at each end making 
sure that the top of the sheets are flush with the top of 
the Top Plate and the sides of the wall sheet overhang 
the Top Plate by approx 15mm as shown.

 

 

• 

Check that the Top Plate is straight then nail the wall 
sheet to the Top Plate, two clouts per pan (see 

fig. 1

).

 

STEP 4:

 

 

• 

Nail the wall sheets to the Bottom Plate at each end ensuring each 
side of wall sheets overhangs the end of Bottom Plate by 15mm. 
Check that the distance between the Top and Bottom Plates is 
correct. (As per diagram in step 1)

 

 

• 

Check that the Bottom Plate is straight then nail the wall sheets to 
the Bottom Plate, two clouts per pan (see 

fig. 1

).

 

Repeat with second side panel ensuring Top Plate is as shown.

 

 

fig.1

 

RIB

 

PAN

 

CLOUT

 

TIMBER PLATE

 

Standard Shed —

 

Bottom Plate will protrude below 

wall sheet by approximately 10mm. 

 

 

Raised base plate shed —

 

Wall sheet will protrude 

 

below the Bottom Plate by 20mm

.

 

15mm

 

15mm

 

1827mm

 

1948mm

 

15mm

 

RIVET

 

RIVET

 

RIVET

 

RIVET

 

BOTTOM PLATE

 

15mm

 

RIVET

 

RIVET

 

Содержание Duratuf Guardian Sheds GL57

Страница 1: ...ASSEMBLY INSTRUCTIONS GL57 BASE SIZE 1 520m x 2 020m ...

Страница 2: ...CHECK OUT OUR ASSEMBLY VIDEO ...

Страница 3: ... process needs to be adhered to to qualify for the steel warranty of your Duratuf Guardian shed Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as above After a storm wash the cladding and the gutters as soon as possible to remove any highly corrosive salt deposits Volcanic Ash Fallout wash as soon as possible removing fall out from roof and gu...

Страница 4: ... 860m 3 Side Wall Angle 1 965m 2 Side Wall Angle 1 935m 2 Side Wall Angle 1 905m 2 Side Wall Angle 1 875m 2 Roof 2 200m 3 Door Sheet Narrow 1 940m 2 Door Sides 1 940m 2 Door Jamb 1 980m 1 Corner Door Jamb 1 980m 1 Door Brace 1 200m 2 Barge 2 200m 2 Spouting 1 555m 1 Door Top Bottom 0 945m 2 Hardware Pack 1 Touchup Paint Brush 1 ...

Страница 5: ...IST 4 TIMBER DESCRIPTION QTY DIAGRAM CHECKED Front Back Bottom Plates H4 Green 1 520 m 2 Front Back Top Plate H1 Red 1 520 m 2 Side Wall Bottom Plates H4 Green 2 020 m 2 Side Wall Top Plates H1 Red 2 022m 2 PACK 2 ...

Страница 6: ...IDE PANELS 1 LAY FOUNDATION 2 ASSEMBLE DOOR QUICK OVERVIEW Top Plate Back Side Wall Sheets Barge Flashing Spouting Roof Sheets Top Plate Side Top Plate Front Bottom Plate Front Bottom Plate Side Back Wall Sheets Front Wall Sheet Door Jambs Door Sheets Door Side Flashing Padbolt Support Door Brace Door Top Bottom Flashing ...

Страница 7: ...through from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bottom plate and the concrete floor See note on page 8 80mm 100mm 7 5mm 20mm Concrete Floor Base Plate Wall Cladding 6 RAISED BASE PLATE OPTION For sheds placed on a raised concrete floor No doubt by now you wi...

Страница 8: ...d assemble door as shown ensuring narrow face of flashing is on the front as per fig 1 STEP 4 On the back of the door place door braces in posi tion as shown in fig 4 Ensure that the top and bottom ends of the braces are under the door flashings as shown in fig 5 and opposite ends of the braces overlap in the middle Rivet door brace flashings onto back of door as shown Where possible rivet from fr...

Страница 9: ...op of timber plates with bottom of sheets flush with each other Rivet sheets together on overlaps as shown STEP 3 Nail wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the top of the Top Plate and the sides of the wall sheet overhang the Top Plate by approx 15mm as shown Check that the Top Plate is straight then nail the wall sheet to the Top Plate two...

Страница 10: ...ith bottom of sheets flush with each other Rivet the sheets together on overlaps as shown STEP 3 Nail the wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the top of the Top Plate and that the sides of the wall sheets overhang the Top Plate by 15mm as shown Check that the Top Plate is straight then nail wall sheets to the Top Plate using two clouts per...

Страница 11: ...TEP 3 Place 1 x Wall Sheet on timber plates ensuring wall sheets fit underneath door jamb flashings Ensure that the top of the sheet is flush with the top of the Top Plate and that the sides of the wall sheet overhang the Top Plate by 15mm as shown Nail wall sheets to Top Plate two clouts per pan Nail the wall sheet to the Bottom Plate making sure that the Plates are the correct distance apart and...

Страница 12: ...e panels while they are screwed together Before fixing ensure that the Side Panel overlaps the Back Panel as shown Using 2 x 40mm screws screw Top Plates together in the corner Using 2 x 40mm screws 2 per join screw the Bottom Plates together in the corner STEP 2 Repeat Step 1 with the second Side Panel ensuring that the Side Panel overlaps the Back Wall Panel STEP 3 Stand up the Front Wall Panel ...

Страница 13: ...x rivets per join STEP 2 Position the Roof Sheets with front overhang of 130mm at each end fig 1 Using 4 x 50mm Clouts predrill and nail the Roof Sheets to the Top Plates through the ribs at each corner ensuring ribs on the Roof Sheets line up with ribs on the Wall Sheets fig 2 STEP 3 Ensure the Front and Back Top Plates are straight Screw the roof sheets to the front back Top Plates using 1 x Roo...

Страница 14: ...UP REMOVE ALL DRILL FILINGS FROM ROOF WALLS AND CHANNELS THOROUGHLY FAILURE TO DO THIS WILL RESULT IN CORROSION AND COULD THEREFORE VOID THE WARRANTY FIT PADBOLT Rivet Padbolt to door and keeper onto Door Jamb as shown 13 YOUR DURATUF GUARDIAN SHED IS NOW COMPLETE RELAX FITTING A GUARDIAN FLOOR KIT OPTIONAL Position the Floor Joists equally between the side Base Plates and skew nail each end with ...

Страница 15: ......

Страница 16: ...icate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Fastenings and fixings Normal wear and tear damage by impact or acts of God Situations where the shed has been used for storage of chemicals manure or corrosion causing products Unauthorized modification of the structure including painting of the cladding Pleas...

Отзывы: