background image

 

 

ASSEMBLE FRONT PANEL

 

10

 

SELECT:

 

 

1 x 1.890 2 Pan Wall Sheet

 

1 x 1.890 1 Pan Wall Sheet

 

1 x 2.020 Top Plate (Red)

 

1 x 2.020 Bottom Plate (Green)

 

2 x 1.890 Door Jamb Flashings

 

16 x 30mm Galv Clouts

 

8 x Rivets

 

STEP 1:

 

 

• 

Lay out 1 x Top Plate and 1 x Bottom Plate on a flat surface 
as shown. 

 

STEP 3:

 

 

• 

Place 2 x Wall Sheets on timber, ensuring wall sheets fit un-
derneath door jamb flashings. 

 

 

• 

Ensure that the top of the sheet is flush with the top of the 
Top Plate and that the sides of the wall sheets overhang the 
Top Plate by 

15mm

 as shown. Nail wall sheets to Top Plate 

(two clouts per pan)

 

 

• 

Nail the wall sheets to the Bottom Plate making sure that the 
Plates are the correct distance apart and that the sides of the 
wall sheet overhang the Bottom Plate by 

15mm

.

 

 

• 

Drill & rivet Door Jamb Flashings to wall sheets using four 

 

rivets equally spaced on each side.

 

IMPORTANT—IF YOU CHOOSE TO RAISE YOUR TIMBER 

BASE PLATE –READ THE FOLLOWING;

 

 

For sheds with Raised Base Plate option only (see page 6), deduct 

30mm from measurement shown between Top and Bottom Plates on 
all wall panels, so cladding protrudes 20mm below bottom plate

.

 

15mm

 

15mm

 

15mm

 

15mm

 

TOP

 

PLATE

 

DOOR

 

JAMB

 

NAIL

 

STEP 2:

 

 

• 

Using 2 x 30mm clouts, nail the Door Jamb Flashing flush 
with the top of the Top Plate at the correct  measurement as 
shown in plan view. Pre drill holes using a 3.5mm drill bit.

 

 

• 

Check the distance between the top and bottom plates then 
use a further 2 x 30mm clouts to nail the Door Jamb Flash-
ings to the bottom Plate. Pre drill holes.

 

NOTE: 

The

 

Doorway is offset 

-

 closer to L/H end but these 

measurements can be swapped so that doorway is 

 

closer to R/H end.

 

203mm 

 

1450mm

 

TOP PLATE

 

DOOR OPENING

 

Plan View

 

367mm 

 

BOTTOM PLATE

 

1859mm

 

TOP PLATE

 

1859mm

 

 

Содержание Duratuf Garrison Sheds PS62

Страница 1: ...ASSEMBLY INSTRUCTIONS PS62 BASE SIZE 2 020m x 0 685m...

Страница 2: ...CHECK OUT OUR ASSEMBLY VIDEO...

Страница 3: ...ocess needs to be adhered to to qualify for the steel warranty of your Duratuf Garrison shed Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as ab...

Страница 4: ...770m 4 Side Wall 1 pan Angle 1 895m 2 Door Sheet 1 850m 2 Door Sheet 1 pan 1 850m 2 Door Sides 1 850m 4 Door Jamb 1 890m 2 Door Brace 1 025m 4 Barge 0 770m 2 Door Top Bottom 0 715m 4 Weatherstrip 1 85...

Страница 5: ...T INCLUDED IN PACK 2 DESCRIPTION QTY DIAGRAM Front Back Bottom Plates H4 Green 2 020 m 2 Front Back Top Plate H1 Red 2 020 m 2 Side Wall Bottom Plates H4 Green 0 685 m 2 Side Wall Top Plates H1 Red 0...

Страница 6: ...1 LAY FOUNDATION 2 ASSEMBLE DOOR QUICK OVERVIEW 4 Top Plate Back Side Wall Sheets Barge Flashing Spouting Roof Sheets Top Plate Side Top Plate Front Bottom Plate Front Bottom Plate Side Back Wall She...

Страница 7: ...hrough from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bottom plat...

Страница 8: ...he front as per fig 1 STEP 4 On the back of the door place door braces in posi tion as shown in fig 4 Ensure that the top and bottom ends of the braces are under the door flashings as shown in fig 5 a...

Страница 9: ...ther Rivet sheets together on overlaps as shown STEP 3 Nail wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the top of the Top Plate and the sides of the...

Страница 10: ...ttom of sheets flush with each other Rivet the sheets together on overlaps as shown STEP 3 Nail the wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the t...

Страница 11: ...rill rivet Door Jamb Flashings to wall sheets using four rivets equally spaced on each side IMPORTANT IF YOU CHOOSE TO RAISE YOUR TIMBER BASE PLATE READ THE FOLLOWING For sheds with Raised Base Plate...

Страница 12: ...h the second Side Panel ensuring that the Side Panel overlaps the Back Wall Panel STEP 3 Stand up the Front Wall Panel Ensure that the Front Wall Sheets overlap the Side Wall Sheets Using 8 x 40mm scr...

Страница 13: ...X 5 RIDGE ROOF SHEET BACK WALL STEP 2 Position the Roof Sheets with the back lining up with the outside edge of the back wall cladding as in fig 4 Using 4 x 50mm Clouts predrill and nail the Roof Shee...

Страница 14: ...alvanised brackets screws and dynabolts Space the brackets evenly around the shed and fix to the Bottom Plate and the concrete slab A 10mm masonry drill bit is required FITTING A GARRISON FLOOR KIT OP...

Страница 15: ...bit drill hole into top and bottom timber plates STEP 1 Place the doors in the panel In open position approx 25mm below top of top plate Using two rivets rivet the top and bottom hinges to the Door Ja...

Страница 16: ...cate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Fastenings and fixings Normal wear and tear damage by impact o...

Отзывы: