background image

 

 

ROOF  ASSEMBLY

 

SELECT:

 

 

2 x 2.200 m Roof Sheets

 

1 x 1.055 m Spouting

 

2 x 2.200 m Barges

 

10 x 50mm Roofing Screws

 

21 x Rivets

 

4 x 50mm Clouts

 

 

12

 

IMPORTANT

 

Use 50mm Clouts only on outside ribs covered by Barge flashings. Predrill holes 
using a 3.5mm drill bit. Use Roofing Screws on all other ribs, ensuring screws are 
not overtightened as this can damage the seals and cause the shed to leak. 

 

STEP 1:

 

 

• 

Ensure Shed is sitting level and square.

 

 

• 

Lay Roof Sheets on the Top Plates.

 

 

• 

Rivet sheets together at overlaps with 2 x rivets per join

.

 

STEP 2:

 

 

• 

Position the Roof Sheets with front overhang of 130mm at each 
end (

fig. 1

).

 

 

• 

Using 4 x 50mm Clouts, predrill and nail the Roof Sheets to the Top 
Plates through the ribs, at each corner, ensuring ribs on the Roof 
Sheets line up with ribs on the Wall Sheets (

fig.2

).

 

STEP 3:

 

 

• 

Ensure the Front and Back Top Plates are straight. 

 

• 

Screw the roof sheets to the front & back Top Plates, using 1 x 
Roofing Screw per rib. (

fig.2

).

 

STEP 4:

 

 

 

• 

Place barge flashings on roof at end of shed ensuring the diagonal 
trimmed end is at the front. (See diagram on pg 5)

 

 

• 

Rivet the Barge Flashings to the roof and the side wall, using four 
rivets on top of barge and four into the side (

fig.3

).

 

Pan

 

Rib

 

fig.2

 

SIDE

 

WALL

 

BACK 

WALL

 

SID

E

 

WA

BOTTOM 

TOP 

130mm

 

fig.1

 

130mm

 

fig.3

 

X 4

 

X 4

 

Barge

 

Spouting

 

fig.4

 

STEP 5:

 

 

• 

Place spouting in position and rivet to Barge Flashings at each end 
and rivet to roof sheets (1 rivet per 1 sheet) 

(fig.4).

 

IMPORTANT—FOR SHEDS WITH OPTIONAL CLEAR ROOF PANEL 

 

Assemble as below, making sure that the Clear Roof Sheets overlap the standard 
roof sheets on both sides. Pre

-

drill and fasten with the 50mm roofing screws 

 

provided.

 Ensuring screws are not overtightened as this can damage the seals 

and cause the shed to leak.

 

Содержание Duratuf Garrison Sheds PL36

Страница 1: ...ASSEMBLY INSTRUCTIONS PL36 BASE SIZE 1 020m x 2 020m...

Страница 2: ...CHECK OUT OUR ASSEMBLY VIDEO...

Страница 3: ...process needs to be adhered to to qualify for the steel warranty of your Duratuf Garrison shed Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as...

Страница 4: ...935m 2 Side Wall Angle 1 905m 2 Side Wall Angle 1 875m 2 Roof 2 200m 2 Door Sheet Narrow 1 940m 2 Door Sides 1 940m 2 Corner Door Jamb 1 980m 2 Door Brace 1 200m 2 Barge 2 200m 2 Spouting 1 055m 1 Do...

Страница 5: ...R PACK CHECK LIST INCLUDED IN PACK 2 DESCRIPTION QTY DIAGRAM Front Back Bottom Plates H4 Green 1 020 m 2 Front Back Top Plate H1 Red 1 020 m 2 Side Wall Bottom Plates H4 Green 2 020 m 2 Side Wall Top...

Страница 6: ...PANELS 1 LAY FOUNDATION 2 ASSEMBLE DOOR QUICK OVERVIEW PARTS LOCATION Top Plate Back Side Wall Sheets Barge Spouting Roof Sheets Top Plate Side Top Plate Front Bottom Plate Front Bottom Plate Side Ba...

Страница 7: ...coming through from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bot...

Страница 8: ...emble door as shown ensuring narrow face of flashing is on the front as per fig 1 STEP 4 On the back of the door place door braces in posi tion as shown in fig 4 Ensure that the top and bottom ends of...

Страница 9: ...p of timber plates with bottom of sheets flush with each other Rivet sheets together on overlaps as shown STEP 3 Nail wall sheets to the Top Plate at each end making sure that the top of the sheets ar...

Страница 10: ...ivet the sheets together on overlaps as shown STEP 3 Nail the wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the top of the Top Plate and that the sides...

Страница 11: ...s es properly Fit remaining rivets 1948mm 1948mm BOTTOM PLATE TOP PLATE STEP 1 Lay out 1 x Top Plate and 1 x Bottom Plate on a flat surface as shown STEP 3 Using 2 x 30mm clouts nail the Door Jamb Fla...

Страница 12: ...els while they are screwed together Before fixing ensure that the Side Panel overlaps the Back Panel as shown Using 2 x 40mm screws screw Top Plates together in the corner Using 2 x 40mm screws 2 per...

Страница 13: ...ibs on the Wall Sheets fig 2 STEP 3 Ensure the Front and Back Top Plates are straight Screw the roof sheets to the front back Top Plates using 1 x Roofing Screw per rib fig 2 STEP 4 Place barge flashi...

Страница 14: ...P REMOVE ALL DRILL FILINGS FROM ROOF WALLS AND CHANNELS THOROUGHLY FAILURE TO DO THIS WILL RESULT IN CORROSION AND COULD THEREFORE VOID THE WARRANTY FIT PADBOLT Rivet Padbolt to door and keeper onto D...

Страница 15: ......

Страница 16: ...cate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Fastenings and fixings Normal wear and tear damage by impact o...

Отзывы: