Illustration 2
The collar should be placed .125” (3.2 mm) from
the tip of the cone. (See Illustration 2) It may be
necessary to adjust this collar with a set of vise‐
grip pliers. Be careful to not strip the threads off
the tube or hose end.
Illustration 3
Slide the gland nut down over the collar. (See
Illustration 3) Insert the 1/4” tube or 1/4” hose
end into tensioner or hydraulic pump. While firmly
holding the tube or hose end to stop it from
rotating, turn the gland nut clockwise (
right hand
thread) and torque the gland nut to 25 FT‐LBS (34
N‐m).
Tips:
Make sure all parts are clean and free from
debris.
Protect the cone on the end of the 1/4” tube
or 1/4” hose end from scratches as this is the
sealing surface.
Replace red plastic caps when finished to
protect the threads and cone.