22 | Replacing 1U xx80 Components
Replacing fans
8. Reattach the power cords and peripherals.
9. Power on the appliance.
Replacing fans
This section describes how to replace fans in the 1U CX 3080 and SteelCentral xx80 appliance. It
includes these sections:
•
“Determining the fan status on 1U CX 3080 appliances” on page 22
•
“Replacing the fans in 1U CX 3080 appliances” on page 22
Important:
You must power down appliances prior to replacing fans.
Determining the fan status on 1U CX 3080 appliances
This section describes how to determine the status of individual fans on 1U CX 3080 appliances.
To determine fan status on 1U CX 3080 appliance
1. Connect to the CLI. For details, see the
Riverbed Command-Line Interface Reference Manual
.
2. At the system prompt, enter the
show stats fan
command. The output and number of fans vary
depending on your appliance. On appliances where each fan has two rotors, each rotor has a unique
status entry.
Replacing the fans in 1U CX 3080 appliances
This section describes how to replace the fan unit in 1U CX 3080 appliances.
The 1U CX 3080 appliance is equipped with two fans that are contained in a single fan unit. You must
use approved fans. To order fans, contact Riverbed Support at
https://support.riverbed.com
.
Important:
The fans aren’t hot swappable; you must power down the appliance before replacing the fans.
To replace the fans in the 1U CX 3080 appliance
1. Power down the appliance.
2. Remove the chassis cover. For details, see