background image

IPAdminTool 

IPAdminTool  is  a  management  tool  to  automatically  scan  all  the 
network  products  for  the  devices’  administrative  tasks,  which 
include  network  configurations,  firmware  update,  device  reboot, 
factory default, and device organization. 

 

To modify the device’s default IP address for a customized network 
area; 

1)

  Find  the  device  from  IPAdminTool’s  list,  and  highlight  the 

device’s name.

 

 

2)

  Right-click  the  mouse,  and  select 

IP  Address

,  and  select  either 

Single

  or 

Multiple 

depending  on  the  selected  number  of  devices. 

 

3)

  Type  the  new  network  information  including  IP  Address.  The 

image above shows the Single IP Change window only. Refer to the 
manual  for  IPAdminTool  in  case  you  need  the  instructions  to 
change multiple IP addresses. 

4) 

Enter  ID  and  PW(if  the  device’s  ID  and  PW  have  never  been 

changed, check the checkbox of ‘Use default ID/PW’.) 

5)

 Click 

Apply

Viewing video on web page 

Once the device’s IP address has been identified, type the URL in a 
web  browser  to  access  the  camera.  At  the  first  time  access,  the 
installation window may pop up like below. 

 

1)

  When  the  browser  asks  to  install  the  AxUMF  software,  click 

Install

 to proceed. 

2)

 When the Setup installation pop-up window appears, click 

Install

 

to preceed with the rest of the installation. 
NOTE 
The figures during the installation process may differ depending on 
the system OS and the IE version. 

SETUP page 

To setup the device configuraiton: 

1)

 Click 

Setup

 on the upper left corner of the web page. 

2)

  Enter  the  user  name  and  the  password  when  the  login  page  is 

displayed.   
(The default user name and the password are 

root

 and 

pass

.) 

3)

 Click 

OK

To  learn  how  to  set  up  the  camera  on  the  web  page  for  the 
advanced configuration, refer to the device’s user manual. 

Reboot

*

 

You can reboot the device via the camera’s webpage, too. 

1)

 Go to 

Setup

 > 

Maintenance

 > 

Reboot

2)

 Click 

Reboot

 to reboot the device. 

Factory Default

*

 

You can initialize the current  settings to the factory default values 
via the camera’s webpage, too. 

1)

 Go to 

Setup 

Maintenance

 > 

Reset All Settings

2)

 Select the items that you want to preserve from the initialization 

among  network  settings,  user  account  information,  and  time 
zone setting. 

3)

 Click 

Reset All Settings

.

 

 
 

 

Safe mode 

Your  device  will  get  restarted  in  safe  mode  if  the  device  does  not 
completely boot certain times. The main causes for safe mode are 
as follows. 

* The power supply is continually unplugged certain times in the middle of 
system booting. 
* The firmware files required for system booting are damaged. 
* There are conflicts in the system settings. 

You  will  see  the  page  to  indicate  that  your device  is  in  safe  mode 
and to guide you what to do in steps. Follow the instructions on the 
webpage according to each step. 

NOTE 

One  of  the  methods  to  update  firmware  is  using  IPAdminTool. 
Please  refer  to  the  manaul  for  IPAdminTool  for  the  detailed 
procedure. 

NOTE 

If your device is still in safe mode after trying to update firmware, 
please contact your local agency to get further assistance

Hexadecimal-decimal conversion table 

Refer  to  the  following  table  when  converting  the  MAC  address  of 
your device to IP address. 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

25 

37 

 

4A 

74 

 

6F 

111 

 

94 

148 

 

B9 

185 

 

DE 

222 

 

26 

38 

 

4B 

75 

 

70 

112 

 

95 

149 

 

BA 

186 

 

DF 

223 

 

27 

39 

 

4C 

76 

 

71 

113 

 

96 

150 

 

BB 

187 

 

E0 

224 

 

28 

40 

 

4D 

77 

 

72 

114 

 

97 

151 

 

BC 

188 

 

E1 

225 

 

29 

41 

 

4E 

78 

 

73 

115 

 

98 

152 

 

BD 

189 

 

E2 

226 

 

2A 

42 

 

4F 

79 

 

74 

116 

 

99 

153 

 

BE 

190 

 

E3 

227 

 

2B 

43 

 

50 

80 

 

75 

117 

 

9A 

154 

 

BF 

191 

 

E4 

228 

 

2C 

44 

 

51 

81 

 

76 

118 

 

9B 

155 

 

C0 

192 

 

E5 

229 

 

2D 

45 

 

52 

82 

 

77 

119 

 

9C 

156 

 

C1 

193 

 

E6 

230 

 

2E 

46 

 

53 

83 

 

78 

120 

 

9D 

157 

 

C2 

194 

 

E7 

231 

0A 

10 

 

2F 

47 

 

54 

84 

 

79 

121 

 

9E 

158 

 

C3 

195 

 

E8 

232 

0B 

11 

 

30 

48 

 

55 

85 

 

7A 

122 

 

9F 

159 

 

C4 

196 

 

E9 

233 

0C 

12 

 

31 

49 

 

56 

86 

 

7B 

123 

 

A0 

160 

 

C5 

197 

 

EA 

234 

0D 

13 

 

32 

50 

 

57 

87 

 

7C 

124 

 

A1 

161 

 

C6 

198 

 

EB 

235 

0E 

14 

 

33 

51 

 

58 

88 

 

7D 

125 

 

A2 

162 

 

C7 

199 

 

EC 

236 

0F 

15 

 

34 

52 

 

59 

89 

 

7E 

126 

 

A3 

163 

 

C8 

200 

 

ED 

237 

10 

16 

 

35 

53 

 

5A 

90 

 

7F 

127 

 

A4 

164 

 

C9 

201 

 

EE 

238 

11 

17 

 

36 

54 

 

5B 

91 

 

80 

128 

 

A5 

165 

 

CA 

202 

 

EF 

239 

12 

18 

 

37 

55 

 

5C 

92 

 

81 

129 

 

A6 

166 

 

CB 

203 

 

F0 

240 

13 

19 

 

38 

56 

 

5D 

93 

 

82 

130 

 

A7 

167 

 

CC 

204 

 

F1 

241 

14 

20 

 

39 

57 

 

5E 

94 

 

83 

131 

 

A8 

168 

 

CD 

205 

 

F2 

242 

15 

21 

 

3A 

58 

 

5F 

95 

 

84 

132 

 

A9 

169 

 

CE 

206 

 

F3 

243 

16 

22 

 

3B 

59 

 

60 

96 

 

85 

133 

 

AA 

170 

 

CF 

207 

 

F4 

244 

17 

23 

 

3C 

60 

 

61 

97 

 

86 

134 

 

AB 

171 

 

D0 

208 

 

F5 

245 

18 

24 

 

3D 

61 

 

62 

98 

 

87 

135 

 

AC 

172 

 

D1 

209 

 

F6 

246 

19 

25 

 

3E 

62 

 

63 

99 

 

88 

136 

 

AD 

173 

 

D2 

210 

 

F7 

247 

1A 

26 

 

3F 

63 

 

64 

100 

 

89 

137 

 

AE 

174 

 

D3 

211 

 

F8 

248 

1B 

27 

 

40 

64 

 

65 

101 

 

8A 

138 

 

AF 

175 

 

D4 

212 

 

F9 

249 

1C 

28 

 

41 

65 

 

66 

102 

 

8B 

139 

 

B0 

176 

 

D5 

213 

 

FA 

250 

1D 

29 

 

42 

66 

 

67 

103 

 

8C 

140 

 

B1 

177 

 

D6 

214 

 

FB 

251 

1E 

30 

 

43 

67 

 

68 

104 

 

8D 

141 

 

B2 

178 

 

D7 

215 

 

FC 

252 

1F 

31 

 

44 

68 

 

69 

105 

 

8E 

142 

 

B3 

179 

 

D8 

216 

 

FD 

253 

20 

32 

 

45 

69 

 

6A 

106 

 

8F 

143 

 

B4 

180 

 

D9 

217 

 

FE 

254 

21 

33 

 

46 

70 

 

6B 

107 

 

90 

144 

 

B5 

181 

 

DA 

218 

 

FF 

255 

22 

34 

 

47 

71 

 

6C 

108 

 

91 

145 

 

B6 

182 

 

DB 

219 

 

 

 

23 

35 

 

48 

72 

 

6D 

109 

 

92 

146 

 

B7 

183 

 

DC 

220 

 

 

 

24 

36 

 

49 

73 

 

6E 

110 

 

93 

147 

 

B8 

184 

 

DD 

221 

 

 

 

 

1 CH Encoder 
1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

1 CH Encoder

 

Encoder1

 

Encoder2

 

Encoder3

 

Encoder4

 

Encoder5

 

Encoder6

 

Encoder7

 

Encoder8

 

Encoder9

 

Encoder10

 

Encoder11

 

Encoder12

 

Encoder13

 

Encoder14

 

Encoder15

 

Encoder16

 

Current PC environment Info 

Give a new unique IP address in the last two sets 
and mirror other information in the other boxes. 

*How to reboot on the device is found in the Part names and functions section on the previous page. 

*How to do factory default on the device is found 
  in the Part names and functions section on the previous page. 

Отзывы: