background image

22

 

 

 

 

 

 

 

 

 

www.rivatech.de 

APPENDIX (

APPENDIX (

APPENDIX (

APPENDIX (D

D

D

D): H

): H

): H

): HEXADECIMAL

EXADECIMAL

EXADECIMAL

EXADECIMAL----

D

D

D

DECIMAL

ECIMAL

ECIMAL

ECIMAL    C

C

C

CONVERSION

ONVERSION

ONVERSION

ONVERSION    T

T

T

TABLE

ABLE

ABLE

ABLE    

Refer to the following table when you convert the MAC address of your device to IP address. 

 
 

Hex

Hex

Hex

Hex     Dec

Dec

Dec

Dec    

00  0 

01  1 

02  2 

03  3 

04  4 

05  5 

06  6 

07  7 

08  8 

09  9 

0A  10 

0B  11 

0C  12 

0D  13 

0E  14 

0F  15 

10  16 

11  17 

12  18 

13  19 

14  20 

15  21 

16  22 

17  23 

18  24 

19  25 

1A  26 

1B  27 

1C  28 

1D  29 

1E  30 

1F  31 

20  32 

21  33 

22  34 

23  35 

24  36 

 

Hex

Hex

Hex

Hex     Dec

Dec

Dec

Dec    

25  37 

26  38 

27  39 

28  40 

29  41 

2A  42 

2B  43 

2C  44 

2D  45 

2E  46 

2F  47 

30  48 

31  49 

32  50 

33  51 

34  52 

35  53 

36  54 

37  55 

38  56 

39  57 

3A  58 

3B  59 

3C  60 

3D  61 

3E  62 

3F  63 

40  64 

41  65 

42  66 

43  67 

44  68 

45  69 

46  70 

47  71 

48  72 

49  73 

 

Hex

Hex

Hex

Hex     Dec

Dec

Dec

Dec    

4A  74 

4B  75 

4C  76 

4D  77 

4E  78 

4F  79 

50  80 

51  81 

52  82 

53  83 

54  84 

55  85 

56  86 

57  87 

58  88 

59  89 

5A  90 

5B  91 

5C  92 

5D  93 

5E  94 

5F  95 

60  96 

61  97 

62  98 

63  99 

64  100 

65  101 

66  102 

67  103 

68  104 

69  105 

6A  106 

6B  107 

6C  108 

6D  109 

6E  110 

 

Hex

Hex

Hex

Hex     Dec

Dec

Dec

Dec    

6F  111 

70  112 

71  113 

72  114 

73  115 

74  116 

75  117 

76  118 

77  119 

78  120 

79  121 

7A  122 

7B  123 

7C  124 

7D  125 

7E  126 

7F  127 

80  128 

81  129 

82  130 

83  131 

84  132 

85  133 

86  134 

87  135 

88  136 

89  137 

8A  138 

8B  139 

8C  140 

8D  141 

8E  142 

8F  143 

90  144 

91  145 

92  146 

93  147 

 

Hex

Hex

Hex

Hex     Dec

Dec

Dec

Dec    

94  148 

95  149 

96  150 

97  151 

98  152 

99  153 

9A  154 

9B  155 

9C  156 

9D  157 

9E  158 

9F  159 

A0  160 

A1  161 

A2  162 

A3  163 

A4  164 

A5  165 

A6  166 

A7  167 

A8  168 

A9  169 

AA  170 

AB  171 

AC  172 

AD  173 

AE  174 

AF  175 

B0  176 

B1  177 

B2  178 

B3  179 

B4  180 

B5  181 

B6  182 

B7  183 

B8  184 

 

Hex

Hex

Hex

Hex     Dec

Dec

Dec

Dec    

DE  222 

DF  223 

E0  224 

E1  225 

E2  226 

E3  227 

E4  228 

E5  229 

E6  230 

E7  231 

E8  232 

E9  233 

EA  234 

EB  235 

EC  236 

ED  237 

EE  238 

EF  239 

F0  240 

F1  241 

F2  242 

F3  243 

F4  244 

F5  245 

F6  246 

F7  247 

F8  248 

F9  249 

FA  250 

FB  251 

FC  252 

FD  253 

FE  254 

FF  255 

 

 

 

 

 

 

 

Hex

Hex

Hex

Hex     Dec

Dec

Dec

Dec    

B9  185 

BA  186 

BB  187 

BC  188 

BD  189 

BE  190 

BF  191 

C0  192 

C1  193 

C2  194 

C3  195 

C4  196 

C5  197 

C6  198 

C7  199 

C8  200 

C9  201 

CA  202 

CB  203 

CC  204 

CD  205 

CE  206 

CF  207 

D0  208 

D1  209 

D2  210 

D3  211 

D4  212 

D5  213 

D6  214 

D7  215 

D8  216 

D9  217 

DA  218 

DB  219 

DC  220 

DD  221 

 

Содержание re1000

Страница 1: ...1 www rivatech de RE1000 RE1000 RE1000 RE1000 Installation Guide Installation Guide Installation Guide Installation Guide ...

Страница 2: ... PARTS INSIDE REFER SERVICING TO QUALIFIED SEERIVCE PERSONEL This symbol is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions in the lit...

Страница 3: ...ault 15 6 6 6 6 WALL WALL WALL WALL MOUNTING MOUNTING MOUNTING MOUNTING 16 16 16 16 APPENDIX A SPECIFICATIONS APPENDIX A SPECIFICATIONS APPENDIX A SPECIFICATIONS APPENDIX A SPECIFICATIONS 17 17 17 17 Summary 17 Electrical Characteristics 18 Environment Condition 18 APPEN APPEN APPEN APPENDIX B POWER OVER ETHERNET DIX B POWER OVER ETHERNET DIX B POWER OVER ETHERNET DIX B POWER OVER ETHERNET 19 19 1...

Страница 4: ...video out for external monitors Video Motion Detection supported Two way mono audio supported Network Network Network Network RTSP HTTP protocol supported 10 100 Base T Ethernet Additional Features Additional Features Additional Features Additional Features RS 232 RS 485 supported USB 2 0 supported Local storage Wireless LAN SD memory card supported PoE supported Built in Video Content Analysis SD...

Страница 5: ... DC power adaptor Mounting bracket Mounting bracket Mounting bracket Mounting brackets s s s 9 9 9 9 Pin terminal block Pin terminal block Pin terminal block Pin terminal blocks s s s Screws and anchor Screws and anchor Screws and anchor Screws and anchor blocks blocks blocks blocks Quick Installation Guide Quick Installation Guide Quick Installation Guide Quick Installation Guide The above conten...

Страница 6: ...ystem is turned on with a connection is made The color of LEDs is subject to change according to the firmware version To change its setting refer to the section 4 5 11 LED Setting 4 5 11 LED Setting 4 5 11 LED Setting 4 5 11 LED Setting of the RE Web RE Web RE Web RE Web Page User s Manual Page User s Manual Page User s Manual Page User s Manual 2 2 2 2 Video Video Video Video Input BNC connector ...

Страница 7: ... is available 6 6 6 6 LAN connector LAN connector LAN connector LAN connector Use the RJ45 LAN connector for 10 100 Base T Ethernet 7 7 7 7 Audio IN OUT Audio IN OUT Audio IN OUT Audio IN OUT The encoder has one channel mono audio input output As the output power for the audio is low an amplifier speaker is needed 8 8 8 8 DI DO DI DO DI DO DI DO The encoder supports two channels for each of DI and...

Страница 8: ...for PTZ controls 10 10 10 10 Reset Reset Reset Reset Reboot the device system or reset the device to its Factory default settings Refer to the section 5 5 5 5 3 3 3 3 Reset Reset Reset Reset for more specific information 11 11 11 11 Power connect Power connect Power connect Power connecto o o or r r r Connect the power adaptor for power supply DC 12V 1A adaptor is needed ...

Страница 9: ...t among these connections can be looped to other equipments as CRT monitor through External External External External Video output connector Video output connector Video output connector Video output connector Make sure to connect the analog video input before you turn on the encoder Otherwise the device must be rebooted to see the normal display if the camera is NTSC because the encoder default ...

Страница 10: ...nnect the sensor Input voltage range 0 VDC minimum to 24 VDC maximum Input voltage threshold 1 V Signal Description COM Connect cable of electronic power source for sensors to this port as shown in the circuit above D1 D2 Connect output of sensors for each port as shown in the circuit above Do not exceed the maximum input voltage or relay rate Do not use voltage and relay type sensor together Caut...

Страница 11: ...elay rating RS RS RS RS 232C 232C 232C 232C RS 232C Terminal Block is used for some devices such as POS terminal block RS 232C Connection RS RS RS RS 485 485 485 485 The RS 485 serial port consists of TRX RX and TRX RX as following the following image Caution RX RS 232C Application TX GND RX TX GND TX RX GND DO DO COM Relay Type X Max 12VDC 1A or 24VAC 500mA Power Device Device Internal ...

Страница 12: ...r IP device is 192 168 XXX XXX You can find the available IP address from the MAC address of your device Please make sure the device and your PC are on the same network segment before running the installation If the network segment between your PC and the device is different change your PC s settings as below IP address 192 168 xxx xxx 192 168 xxx xxx 192 168 xxx xxx 192 168 xxx xxx Subnet mask 25...

Страница 13: ...MAC address and etc IPAdminTool is provided with SDK at the following SDK path SDK root BIN TOOLS AdminTool To use the IPAdminTool and view the live video on a web page To use the IPAdminTool and view the live video on a web page To use the IPAdminTool and view the live video on a web page To use the IPAdminTool and view the live video on a web page 1 Start IPAdminTool Names and info of currently ...

Страница 14: ...ternet Explorer windows and go to Program Files Program Files Program Files Program Files AxInstall AxInstall AxInstall AxInstall folder on your computer Then run Uninstall exe Uninstall exe Uninstall exe Uninstall exe and try to perform the steps 1 to 4 above again 5 5 5 5 2 2 2 2 2 2 2 2 View video using IP address View video using IP address View video using IP address View video using IP addre...

Страница 15: ...set Reset 1 While the device is in use press and hold the Reset button 2 Release the Reset button after 3 seconds 3 Wait for the system to reboot 5 5 5 5 4 4 4 4 Factory Default Factory Default Factory Default Factory Default 1 Disconnect the power supply from the device 2 Connect the power to the device with the Reset button pressed and held 3 Release the Reset button after 5 seconds 4 Wait for t...

Страница 16: ...WALL WALL WALL MOUNTING MOUNTING MOUNTING MOUNTING To wall mount the encoder follow this instruction The encoder has one mounting hole on each side Mount the device using the included screws and anchor blocks Refer to the image below ...

Страница 17: ...Deinterlacing Supported DSP Motion Detection Supported OSD Supported DSP Burnt in Text Digital Supported DSP Output 1 Loop Out BNC connector Audio Input output 1 1 channel Compression Format G 711 Function Digital Input output 2 2 channel RS 485 Supported RS 232 Supported Network 10 100 Base T Power over Ethernet Supported Protocol TCP IP UDP IP HTTP RTSP RTCP RTP UDP RTP TCP SNTP mDNS UPnP SMTP S...

Страница 18: ...in 1 43Vp p Min 1 35Vp p max 1 49 Vp p 39 KΩ Audio Output Lineout 46mW Power 16 Ω Sensor D I TTL level 4 5V threshold Max 50mA Alarm D O Max 500mA 24VAC or 1A 12VDC Power Source Approx 12 V DC 240mA or PoE IEEE802 3af Class 0 Environment Condition Environment Condition Environment Condition Environment Condition Operating Temperature 20 ºC 60 ºC 4 ºF 140 ºF Operating Humidity Up to 85 RH ...

Страница 19: ...e input voltage range and provides a regulated low ripple and low noise output The DC DC converter also has built in overload and short circuit output protection Note For proper activation of 12V PoE the Category 5 cable must be shorter than 140m and conform the PoE standard PoE compatibility PoE compatibility PoE compatibility PoE compatibility With non Power Sourcing Equipment PSE With non Power...

Страница 20: ...wer classification Power classification Power classification The PoE Power Class supported by the IP device is Class 0 Class Usage Minimum Power Levels Output at the PSE Maximum Power Levels at the Powered Device 0 Default 15 4W 0 44 to 12 95W ...

Страница 21: ...21 www rivatech de APPENDIX APPENDIX APPENDIX APPENDIX C C C C DIMENSIONS DIMENSIONS DIMENSIONS DIMENSIONS Unit mm H 264 Network Video Encoder 141 4 103 4 121 7 37 7 ...

Страница 22: ... 101 66 102 67 103 68 104 69 105 6A 106 6B 107 6C 108 6D 109 6E 110 Hex Hex Hex Hex Dec Dec Dec Dec 6F 111 70 112 71 113 72 114 73 115 74 116 75 117 76 118 77 119 78 120 79 121 7A 122 7B 123 7C 124 7D 125 7E 126 7F 127 80 128 81 129 82 130 83 131 84 132 85 133 86 134 87 135 88 136 89 137 8A 138 8B 139 8C 140 8D 141 8E 142 8F 143 90 144 91 145 92 146 93 147 Hex Hex Hex Hex Dec Dec Dec Dec 94 148 95...

Страница 23: ...ersion 03A 01 10 15 2009 Added the Cross Reference 03A 02 12 09 2009 Corrected Errata about Network Protocol 03A 03 02 24 2010 Modified for end users 03A 04 04 06 2010 Added LAN cable specification for PoE 04A 00 04 20 2010 FW v1 02 04 updated 05A 00 09 07 2010 FW v1 06 02 updated Removed VCA contents from the Specification section Added hexadecimal decimal conversion table 06A 00 10 01 2010 FW v1...