2.
Disconnect the power cord from the Camplifiers mains input socket !
3. Switch OFF the power switch to its “0” position.
4. Turn the voltage selector switch to the required mains input voltage. Use a flat
screw driver for that.
5. Select the appropriate fuse value for your voltage selection.
For a safe operation, the mains input fuse must be selected according to the mains
input voltage.
Mains voltage
Fuse value
115V
2AT (slow blow)
230V
1AT (slow blow)
Exchanging the fuse is easy.
Use a small flat screw driver to pry out the mains fuse compartment :