7 Maintaining the machine
22
We reserve the right to make technical modifications.
Rittal electrical crimping machine R8 E
EN
7.5
Replacing the insulation stripping blade
Warning!
Electrical shock caused by working on live components!
◼
Before working on the machine, it must be disconnected from
the power grid.
Caution!
There is risk of finger injuries at the insulation stripping blades.
◼
Never touch the blade.
◼
Set insulation stripping stage 99.
◼
Switch off the machine.
◼
Open the flap and remove the belt.
◼
Close the flap.
◼
Press the display and switch on the machine.
The machine travels to the blade replacement position, see display.
◼
Switch off the machine.
◼
Open the flap.
◼
Remove the screws (see fig. 19, item 1).
◼
Replace the insulation stripping blade (see fig. 19, item 2).
◼
Insert the insulation stripping blade in the blade holder until the limit stop.
◼
Close the flap.
◼
Switch on the machine, see display.
◼
Press the display for 3 seconds.
The machine travels automatically to the initial position.
◼
Select the insulation stripping stage.
◼
Switch off the machine.
◼
Insert the wire end ferrule belt.
Fig. 19:
Replacing the insulation stripping blade
7.6
Replacing ferrule separating blade
Caution!
There is risk of finger injuries at the ferrule separating blade.
◼
Never touch the blade.
◼
Switch off the machine.
◼
Open the flap.