6 Troubleshooting
14
We reserve the right to make technical modifications.
Rittal S22 insulation stripping machine
EN
Fig. 8:
Wire-holding pliers
5.3
Replacing the insulation stripping blade
Warning!
Electrical shock caused by working on live components!
◼
Before working on the machine, it must be disconnected from
the power grid.
◼
Loosen the screws and remove the front panel.
◼
Loosen the fastening screws and remove the blade fastener.
◼
Either turn the insulation stripping blade or replace it with a new one. Reinsert
the blade fastener and tighten the fastening screws.
Fig. 9:
Interior view
Key
1
Actuator lever with ball-pressure screws
2
Fastening screw
3
Insulation stripping blade
4
Blade fastener
◼
Close the front panel. To do this:
–
Push the actuator level to the left.
–
Place the front panel and, by moving from right to left, fasten it to the front
frame of the machine (attach with the alignment pin on the right-hand side).
–
Fasten the front panel with the screws.
6
Troubleshooting
6.1
Machine does not start
The power supply is interrupted.
◼
Check the mains cable and the fuses.
1
4
4
2
2
3
3
Содержание AS 4050.451
Страница 1: ...AS 4050 451 Stripping machine S22 Operating instructions ...
Страница 18: ...Notes Rittal S22 insulation stripping machine We reserve the right to make technical modifications 18 EN ...
Страница 19: ...Notes Rittal S22 insulation stripping machine We reserve the right to make technical modifications 19 EN ...
Страница 20: ...Notes 20 We reserve the right to make technical modifications Rittal S22 insulation stripping machine EN ...