Rittal Wire Station WS 540
Technical changes reserved
9
4 Product description
EN
4
Product description
The Wire Station WS 540 was developed and optimised to permit ergonomic,
effective, and time-saving working. The Wire Station WS 540 has four lockable
castors that allow the Wire Station WS 540 to be moved anywhere required.
The height-adjustable work surface of the Wire Station WS 540 allows it to be
adjusted individually to your work situation.
The wide range of options is an additional advantage. We developed them so
you can extend the Wire Station WS 540 in accordance with your individual
needs and requirements. All possible options are listed in Section "9".
4.1
DESKLINE® DL6 system
Each DESKLINE® DL6 drive is equipped with a motor. The software in the CBD6
ensures parallel running and memory function, even for unbalanced loading of
the table. This software also includes the Soft Start/Stop function that ensures
smooth starting and braking of the table.
4.2
Use of the DESKLINE® DL6 system
Irrespective of the weight, the switch-on duration of 10% ~ 6 minutes/hour or
max. 2 minutes for continuous operation specified on the data sheet must
not
be exceeded, because this can cause overheating of the motor, brake or spindle
nut. Exceeding the switch-on duration can significantly reduce the service life of
the system.
4.3
PIEZO™ function description
To provide optimised protection against jamming and blocking the work surface,
LINAK has developed DL columns with integrated PIEZO sensor. This option
minimises the risk of damage on a table caused by an obstruction jamming or
blocking in the rising or lowering direction. For example, during downward travel
on a stool or container or during upward travel against a windowsill. The system
improves personal safety to some extent. It does not, however, satisfy the
regulations regarding personal safety, i.e. personal protective equipment must
also be worn.
Содержание 4051.100
Страница 1: ...Wire Station WS 540 Assembly and operating instructions 4051 100 ...
Страница 13: ...Rittal Wire Station WS 540 Technical changes reserved 13 5 Assembly and commissioning EN ...
Страница 15: ...Rittal Wire Station WS 540 Technical changes reserved 15 5 Assembly and commissioning EN ...
Страница 17: ...Rittal Wire Station WS 540 Technical changes reserved 17 5 Assembly and commissioning EN Cover A control unit ...
Страница 18: ...5 Assembly and commissioning EN 18 Technical changes reserved Rittal Wire Station WS 540 Cover B socket strip ...
Страница 39: ...Rittal Wire Station WS 540 Technical changes reserved 39 9 Options EN Fig 21 Vertical mounting brace assembly ...
Страница 41: ...Rittal Wire Station WS 540 Technical changes reserved 41 Notes ...
Страница 42: ...Notes 42 Technical changes reserved Rittal Wire Station WS 540 ...
Страница 43: ...Rittal Wire Station WS 540 Technical changes reserved 43 Notes ...