RITS-N FT400 Скачать руководство пользователя страница 2

MSIP

-

CRM

-

RSN

-

FT400

Thank you for purchasing the FT400 remote control
FT400 is a remote control for automatic door by using 2.4GHz frequency.
Please read this manual carefully for the safe and accurate use of this product.

y

is product.

1

 

Product compositions and specifications

2

 

How to use

You can select one of the following two methods to register a transmitter / receiver (pairing).

3

 

Registering the FT400 with R24 receiver 

Ø2.3 x 8 Round head Screw
Battery 1.5V Size AAA

FT400 remote control (Transmitter)

FT400

User manual
Power supply
Transmitting frequency

1.5V * 1 (Size AAA Battery) 
2.4GHz

Transmitting distance
Power consumption

Up to10m  (When installed in steel structures : Up to 2m )
100mA under

Operating temp

-20

 ~ 50

1 EA
1 EA
1 EA
1 EA

Dimensions

36 x 79 x 16 (mm)

FT400 (Transmitter)

FM type remote control

You can use “Hold open” and  “Lock”  Function. Please refer to below.

Dip Switch

Button A

 : Open

Button C 

: Lock

Button B

 : Hold open

Button D

 : Unlock

 When Locked, only works with FT400 until it is unlocked.

 In case of power failure when locked, lock condition will be kept.

※ 

If you press the lock button while the door is hold open mode, the door will be closed and locked.

Components

Specifications

Dip Switch

Method 2: Registration using push buttons

1. How to register

- Connect the power to the R24 receiver.
- Press the button A on FT400 while pressing the register

button  on R24 receiver.

2. How to delete

- Connect power to the R24 receiver.
- Press the button B on FT400 while pressing the delete

button on R24 receiver.

-     The green LED will flash and deletion will be completed.

-     The red LED will flash and registration will be completed.

3. How to delete all

- Press the register

button and delete 

 button on R24 receiver for 5 seconds at the same time.

- The green LED will flash three times when all registered transmitters have been deleted.

Dip Switch

 Registration using push buttons should be done when the dip switches  

     of both FT400 and R24 are in OFF position.

※ 

Up to 10 FT400 transmitters can be registered with one R24 receiver using this method.

LED

In case of using Lock Function.

Automatic door controller 

Connector

Yellow 

 2 

(Output contact)

White x 2 

(Input contact)

Power 

(AC/DC12V~24V) 

Gray 

 2 

Register Button

Delete Button DIP switch for channel setting

Connection 

Point

Method 1: Registration using dip switches

 Pairing cannot be done if all DIP switches of both FT400 and R24 are in OFF position.

 An unlimited number of FT400 transmitters can be registered with one R24 receiver.

Set the dip switches in the same sequence while power is not connected.