FT400
Thank you for purchasing the FT400 remote control
FT400 is a remote control for automatic door by using 2.4GHz frequency.
Please read this manual carefully for the safe and accurate use of this product.
y
is product.
1
.
Product compositions and specifications
2
.
How to use
You can select one of the following two methods to register a transmitter / receiver (pairing).
3
.
Registering the FT400 with R24 receiver
Ø2.3 x 8 Round head Screw
Battery 1.5V Size AAA
FT400 remote control (Transmitter)
FT400
User manual
Power supply
Transmitting frequency
1.5V * 1 (Size AAA Battery)
2.4GHz
Transmitting distance
Power consumption
Up to10m (When installed in steel structures : Up to 2m )
100mA under
Operating temp
-20
℃
~ 50
℃
1 EA
1 EA
1 EA
1 EA
Dimensions
36 x 79 x 16 (mm)
FT400 (Transmitter)
FM type remote control
You can use “Hold open” and “Lock” Function. Please refer to below.
Dip Switch
Button A
: Open
Button C
: Lock
Button B
: Hold open
Button D
: Unlock
※
When Locked, only works with FT400 until it is unlocked.
※
In case of power failure when locked, lock condition will be kept.
※
If you press the lock button while the door is hold open mode, the door will be closed and locked.
Components
Specifications
Dip Switch
②
Method 2: Registration using push buttons
1. How to register
- Connect the power to the R24 receiver.
- Press the button A on FT400 while pressing the register
Ⅰ
Ⅰ
button on R24 receiver.
2. How to delete
- Connect power to the R24 receiver.
- Press the button B on FT400 while pressing the delete
Ⅱ
button on R24 receiver.
- The green LED will flash and deletion will be completed.
- The red LED will flash and registration will be completed.
3. How to delete all
- Press the register
Ⅰ
button and delete
Ⅱ
button on R24 receiver for 5 seconds at the same time.
- The green LED will flash three times when all registered transmitters have been deleted.
Dip Switch
※
Registration using push buttons should be done when the dip switches
of both FT400 and R24 are in OFF position.
※
Up to 10 FT400 transmitters can be registered with one R24 receiver using this method.
LED
In case of using Lock Function.
Automatic door controller
Connector
Yellow
ⅹ
2
(Output contact)
White x 2
(Input contact)
Power
(AC/DC12V~24V)
Gray
ⅹ
2
Register Button
Delete Button DIP switch for channel setting
Connection
Point
①
Method 1: Registration using dip switches
※
Pairing cannot be done if all DIP switches of both FT400 and R24 are in OFF position.
※
An unlimited number of FT400 transmitters can be registered with one R24 receiver.
Set the dip switches in the same sequence while power is not connected.