Ritron Quick Assist RQT-150-PB Скачать руководство пользователя страница 8

qtm9322b.pm5

For assistance, call RITRON at 800-USA-1-USA (800-872-1872) or visit us at www.ritron.com

  — 6 —

NOTE: When programming,

 use either fresh Alkaline

batteries (or an external power supply), to power

the Quick Assist. 

When programming is fin-

ished,

 you may either insert Ni-Cd batteries or

leave Alkaline batteries in place.

WARNING: DO NOT attempt to charge Alkaline

batteries from an ex12VDC

power supply.

When powering Quick Assist with ALKALINE BATTERIES

,

set J103 as follows to disconnect the charging current

paths:
a. To set the Quick Assist for use with alkaline batteries,

move Jumper J103 to cover only one pin of the jumper

base, as shown in FIG-4; this setting prevents the

flow of charging current.

b. Dial 

"943"

 to program the Quick Assist for use with

alkaline  batteries.

When powering Quick Assist with NI-CD BATTERIES

, set

J103 as follows to connect the charging current paths:
c. Cover both pins with Jumper J103, as shown in   FIG-

4,  to  charge  the  Ni-Cd  batteries  from  the  External

Power  connection.

d. Dial 

"944"

  to  adjust  the  Quick  Talk  voltage;  the  unit

then transmits a "Low Battery" phrase.

NOTE: Because  Ni-Cd  batteries  self-discharge  rapidly,

constantly  charge  them  with  external  +12VDC

power.

J103 JUMPER SETTINGS

FOR BATTERY TYPE

FIG—4.  J103 POSITION FOR USE WITH

ALKALINE OR NI-CD BATTERIES

Alkaline

NI-CD

TO  CONNECT  AN  EXTERNAL  12 VDC  POWER  SUPPLY:

The  standard  Quick  Assist  is  not  set-up  for  use  with  an

external power supply.
To modify the Quick Assist for use with an external power

supply,  use  the  following  instructions.

1. Carefully drill or punch a 0.484"  hole in the bottom of

the Quick Assist enclosure.

2. Install Ritron #02500127 strain relief into the drilled

hole.

3. Use Ritron #RPS-203 Power Supply (11-15 VDC,

200 mA), or equivalent, to power the Quick Assist.

The Quick Assist requires 11-15 VDC, 150 mA

minimum.

4. Connect the External Power Supply to Quick Assist

positive and negative terminals, as shown in FIG-6.

CONNECTING AN EXTERNAL

12 VDC POWER SUPPLY

FIG—6.    EXTERNAL  POWER  SUPPLY

CONNECTIONS

   

SWITCH 1

EXTERNAL POWER

SUPPLY

+

-

Содержание Quick Assist RQT-150-PB

Страница 1: ...ksofRITRON INC Quick Talk is trademark of RITRON INC P O Box 1998 Carmel IN 46032 1998 505 W Carmel Dr Carmel IN 46032 USA PH 317 846 1201 800 USA 1 USA 800 872 1872 FAX 317 846 4978 E mail quickassis...

Страница 2: ...RS ii WARNINGS AND CAUTIONS ii ACCESSORIES AND OPTIONS ii INTRODUCTION 1 General Information 1 Care and Maintenance 1 PROGRAMMING 2 Before Programming the Unit 2 Programming the Transmitter Frequency...

Страница 3: ...attempt to clean the printed circuit board which is located inside the housing Batteries Use only fresh new alkaline batteries when programming Quick Assist Acceptable brands and types are Duracell MX...

Страница 4: ...ne to stop programming For DQC codes 7 Find your 3 digit DQC Code in Table 3 page 2 If your code does not appear in Table 3 call your radio service provider or Ritron 8 Pick up the telephone receiver...

Страница 5: ...254 1 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 6Z 6A 6B 7Z 7A M1 QUICK ASSIST QC CODE Freq Hz Freq Hz Other Radio Brands Tone Code TABLE 2 QUIET CALL TONE CODES 2...

Страница 6: ...l 5 Programming of the Ritron Quick Assist is complete E TO PROGRAM THE ASSISTANCE IS NO LONGER NEEDED MESSAGE 1 Pick up the telephone receiver and listen for the acknowl edge tone 2 Dial 311 Quick As...

Страница 7: ...If your frequency has more than three numbers past the decimal point it is probably set for narrowband Example 467 7625 MHz 467 8125 Wide Refer to FIG 2 To set your Quick Assist into wideband position...

Страница 8: ...103 as shown in FIG 4 to charge the Ni Cd batteries from the External Power connection d Dial 944 to adjust the Quick Talk voltage the unit then transmits a Low Battery phrase NOTE Because Ni Cd batte...

Страница 9: ...kaline batteries before programming the unit 4 SWITCH 1 TERMINALS Switch 1 terminals connect to the unit s front panel customer push button When the button is pressed and released the Quick Assist tra...

Страница 10: ...on with sealant tape and press it securely in place Refer to sealant instructions 5 To install the Optional Message Placard align it with the center of its hole over the front push button also align t...

Страница 11: ...er scan VHF models only automatically finds NOAA broadcasts Other features include Interference Eliminator Loud and Clear Audio Removable Quick Swap Battery and Drop in Charging Capability Accessories...

Страница 12: ...ne lines Ideal for Hotels Motels Golf Courses Schools Public Parks Playgrounds Roadsides Marinas Parking Lots or Garages Receiving or Delivery Docks Campuses Shopping Malls Beachs and Pools Campground...

Страница 13: ...eration modification neglect accident or act of God or the use of covered products other than in normal and customary manner or improper testing or installation Defects or damages from unauthorized di...

Отзывы: