Setup
DIP Switch Settings
There are two sets of DIP switches which must be set.
Figure 1
SWITCH
POSITION
OPERATION
1
DOWN
SETS MODE TO MASTER
UP
SETS MODE TO SLAVE
2
3
DOWN
LOW
DOWN
POWER
UP
MEDIUM
LOW
DOWN POWER
DOWN MEDIUM
UP
POWER
UP HIGH
UP POWER
4
DOWN
NORTH AMERICA
UP
AUSTRALIA
5
DOWN
9,600 BAUD (hardwired)
UP
38,400 BAUD (hardwired)
6
MUST BE DOWN
7
DOWN
NORMAL MODE
UP
SIGNAL STRENGTH TEST
8
MUST BE DOWN
1)
NOTE:
Any time DIP switch settings are changed, the RESET switch must be pressed.
2) LINK LED (Figure 1)
– For a Master unit, if this LED is on SOLID, it indicates that the
unit is successfully connected to at least one Slave. For a Slave unit, this LED indicates
that it is successfully connected to a Master.
3) TX\RX LEDs (Figure 1)
– These LEDS indicate the transmission and receipt of data.