background image

L.

 

Fenwal Thermostat 

–  The adjustable range is from 0

o

. F (-18

o

  C) to 100

o

  F (38

o

  C). 

Thermostat is not preset at factory. Fill the trough to proper water level. Check the water 

temperature with a thermometer. The next morning, check the water temperature again. If the water 

is warmer than desired, turn the thermostat down. If there is ice forming on the surface of the water, 

turn the thermostat up. Only slight adjustments should be made to the thermostat at any time. A 

1/16 turn on the thermostat will change the water temp. 7

o

  F (4

o

  C). 44

o

F (7

C) in the trough 

represents the most economical operation. Counter clockwise raises the thermostat setting. 

M. 

Seal the Base

 - After the unit is completely installed, apply a bead of caulking around the base of the 

fountain to ensure no wind enters through the base of the unit.

 

NOTE:

 

Sealing the bottom of the unit from cold air is an important aspect of the unit's thermal 

performance.

 

N.

 

Drain Plug 

– Insert the pre-assembled drain plugs firmly into the drain holes from inside the trough 

at each end. Wetting the plug can aid in installation.

  

O.

 

Valve Frame and Cover

  –  Before installing the 

valve chamber frame, the weather seal must be 

installed on the frame (right).  The seal is installed by 

removing the paper backing from the adhesive side 

and then starting at the midpoint of the frame leg; 

attach the seal to the frame.  Work your way around 

the frame with the seal as close to the inside edge as 

possible and then up the other leg to the halfway 

point.  At this time cut any extra foam seal as needed 

then repeat for other side.  

 

 

The frame can then be attached to the casing  and 

trough  using the T-bolts  and nuts provided in parts 

bag.  The T-Bolts slide into the four T-shaped  holes 

(shown below) located near the center of each trough 

railing. Twisting the base of the T-bolt, once inserted, 

helps the bolt sit upright while installing the frame. A 

washer should be used on the head of the screw as 

well as under the nut. Tighten securely.

 

 

 

 

 

OmniMaster Series Instruction Manual

5

11 October, 2017

Содержание OmniMaster 8

Страница 1: ...fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and understand all instructions before installi...

Страница 2: ...stalled under fountain to allow for easier servicing For optimum serviceability a stop and waste valve can be installed below frost level to drain water when unit is not in use Vertical supply line mu...

Страница 3: ...and platform should slope away from the fountain for drainage A rough broom finish to concrete surface provides better footing for livestock F Anchoring Fountain OmniMaster 8 fountains have mounting...

Страница 4: ...r Uncoil cable heater and loop around the valve Attach the remaining part of the cable heater to the water supply as far down the riser tube as possible with the cable twist ties provided This heater...

Страница 5: ...MAY RESULT IN LOSS OF LIVESTOCK PERSONAL INJURY OR DEATH NOTE National Local electrical codes may require livestock waterers installed in feedlots in open feeding area to be grounded by a separate str...

Страница 6: ...ormance N Drain Plug Insert the pre assembled drain plugs firmly into the drain holes from inside the trough at each end Wetting the plug can aid in installation O Valve Frame and Cover Before install...

Страница 7: ...gs to drain out the water and debris You can shut off the water with the shut off valve located under the unit or by holding the float in the up position After the water and debris has drained reinsta...

Страница 8: ...ered in riser tube Check that riser tube is free of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between...

Страница 9: ...3 Short 2 8 18452 Bolt 3 8 x 3 SS 2 pkg 1 pkg NS 14866 Seal Foam 10 Roll 3 9 18854 OM 8 Frame Screws 1 pkg NS 15931 Hose Clamp 1 SS 5 pkg 1 pkg 10 18448 T Bolt w Wingnut 3 8 pkg 1 pkg NS 18614 Adapte...

Страница 10: ...rights which vary from state to state All warranty claims must be processed through an Authorized Ritchie Dealer Distributor Proof of purchase is required This warranty is not transferable The period...

Отзывы: