background image

D.

 

Riser Tube

 - Install a riser tube and extend it at least one foot below frost line or 

down to horizontal underground water line. For optimum water line protection, use 

the 12” diameter insulated 

Ritchie Thermal Tube

, part numbers and sizes are shown 

to the right. Tube opening must be kept clear. 

NOTE: The supply line touching the riser tube is the most common cause of 

the supply line freezing. Do not surround the supply line with insulation, wood, 

or other foreign material. Any foreign material in the tube may cause frost to 

migrate to the supply line causing it to freeze.

 

E.

 

Mounting Platform

 - A concrete platform (see diagram) must be provided for all fountains. Use a minimum 

of 4” thick, (6” recommended thickness), large enough to accommodate fountain, and additional 4-6” step (on top 

of the platform) extending 18” out from each side of the unit. This will protect the unit from manure handling 

equipment, as well as discouraging animals from defecating in the fountain. Extending the platform provides 

animals a place to stand while drinking, consider the size of your animals when determining the dimensions of your 

platform. The concrete step and platform should slope away from the fountain for drainage. A rough broom finish 

to concrete surface provides better footing for livestock. 

F.

 

Hose Connection 

- Connect hose fitting to shut-off valve at top of concrete. Slip on barb fitting with furnished 

clamps. Hose should not touch insulation or outside surface of fountain. Place the hose under the fountain as you 

move the unit in place over the riser tube.

 

G.

 

Preparing the Bottom - 

Apply the provided foam weather stripping to the bottom of the fountain, following 

along the outside edge of the fountain.   

H.

 

Anchoring Fountain

 - Your fountain has four built-in hold-down locations to anchor your unit securely to the 

concrete pad. The use of 3/8” x 5” stainless steel expansion anchor bolts (not included) is recommended for concrete 

installations. Anchor bolts are available from Ritchie in a two pack, part # 16555. Fender washers are supplied for 

use with anchors.  

I.

 

Assemble Standpipe

–  Install standpipe into hole in 

trough. Rubber O-ring is to be on inside of trough. Tighten 

nut securely to prevent leaks. Do not overtighten or O-ring 

may become dislodged. 

 

 

Ritchie Thermal Tube 

Part # 

Description 

18158 

1’ Top Section 

16417 

2’ Top Section 

16612 

4’ Top Section 

16416 

2’ Extension 

ULTRA-Fount Instruction Manual

2

August 13, 2022

Содержание Classic Equine ULTRAFOUNT ES1

Страница 1: ...ou have just purchased the finest watering fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and...

Страница 2: ...r fountain to allow for easier servicing For optimum serviceability a stop and waste valve can be installed below frost level to drain water when unit is not in use Vertical supply line must be center...

Страница 3: ...of your platform The concrete step and platform should slope away from the fountain for drainage A rough broom finish to concrete surface provides better footing for livestock F Hose Connection Conne...

Страница 4: ...POWER IF THE WATER SUPPLY IS TO BE SHUT OFF FOR AN EXTENDED AMOUNT OF TIME FAILURE TO TURN OFF POWER CAN RESULT IN DAMAGE TO THE WATERING FOUNTAIN WARNING THIS INSTALLATION MUST BE MADE AND MAINTAINED...

Страница 5: ...iagram To attach the valve you will need a 3 8 socket with driver Align holes of white valve bracket with the holes on the trough tab as shown at right Securely tighten the screw being careful to not...

Страница 6: ...been given supervision or instructions concerning use of the appliance by a person responsible for their safety V Cleaning Your Fountain To clean your watering fountain you will need a good stiff bris...

Страница 7: ...e freezing Check that flexible hose does not touch side of casing or frame Check for air gaps between casing and concrete floor Valve won t stop dripping Check the float adjustment Check that float is...

Страница 8: ...8753 Access Panel Hardware Pkg 1 pkg 18 13613 Float with Short Arm pkg 1 pkg 6 18718 Cover Latch Hardware Pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 18751 U...

Страница 9: ...g 1 pkg 18 13613 Float with Short Arm pkg 1 pkg 6 18718 Cover Latch Hardware Pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 18751 ULTRAFOUNT Accessory pkg 1 pkg...

Страница 10: ...ent nor to any product that is installed and or used contrary to Ritchie Industries installation instructions and instructions for use The limited warranty shall also not apply to any product whose ex...

Страница 11: ...This page intentionally left blank ULTRA Fount Instruction Manual 10 August 13 2022...

Страница 12: ...Part 24076 August 13 2022...

Отзывы: