Cattle Fountain, Combination Fountains, AC Series 

Installation Instructions

 

A.

 

Location

 - Putting the fountain in a location that offers protection from the wind will enhance the 

performance of the fountain. Livestock will tend to gather in this protected area, enticing them to drink more. 

Access panel should be opposite of prevailing winter wind to give additional protection to the supply line.  

B.

 

Water Supply Line - 

Horizontal underground water line (1) should be sized to account for pressure drop, 

relating to distance, and placed well below frost line. A one-inch vertical supply pipe (2) is recommended. A shut-

off valve (3) should be installed under fountain to allow for easier servicing. For optimum serviceability, a stop 

and waste valve can be installed below frost level to drain water back when unit is not in use. Vertical supply line 

must be centered in riser tube (4) to provide an air space between the line and frozen ground outside of tube. 

Flush water supply line thoroughly before connection to fountain. Water supplies with foreign material such as 

sand, rust, etc. may require a filter to keep fountain valve working properly. 

C.

 

Electric Supply 

– It is usually most cost effective to run your electrical line the same time you are trenching 

your water supply. 

Any electrical service must be installed and maintained by a qualified electrician.

 

D.

 

Riser Tube

 - Install a riser tube and extend it at least one foot below frost line 

or down to horizontal underground water line. For optimum water line protection, 

use the 12” diameter insulated Ritchie Thermal Tube, part numbers and sizes are 

shown to the left. Tube opening must be kept clear. 

NOTE: 

The supply line 

touching the riser tube is the most common cause of the supply line freezing. 

Do not surround the supply line with insulation, wood, or other foreign 

material. Any foreign material in the tube may cause frost to migrate to the 

supply line causing it to freeze. 

Ritchie Thermal Tube 

Part # 

Description 

18158  1’ Top Section 

16417  2’ Top Section 

16612  4’ Top Section 

16416 2’ 

Extension 

Use in combination to reach 
desired depth 

Cattle, Combination, and AC Series 

Fountains Installation Instructions

1

17 October, 2012

Содержание 1AC

Страница 1: ...Congratulations you have just purchased the finest watering fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions c...

Страница 2: ...fore connection to fountain Water supplies with foreign material such as sand rust etc may require a filter to keep fountain valve working properly C Electric Supply It is usually most cost effective...

Страница 3: ...concrete to keep air from leaking under fountain H Final Water Connection Connect the top of the supplied hose to the valve cut hose to proper length and slip onto the barb fitting of the valve assemb...

Страница 4: ...t be made and maintained in strict conformity with National Local plumbing codes and National Local electrical codes CSA in Canada The applicable provisions of these codes take precedent Failure to ma...

Страница 5: ...d If you are using solid wire then you will be able to just push the wire into the slot Stranded wire will require you to press the button down HEATER 240V FENWAL THERMOSTAT CABLE HEATER TERMINAL BLOC...

Страница 6: ...nd fix any leaks Adjust float for a water depth of 2 inches below top of trough or overflow pipe by adjusting the thumbscrew or wing nut P Install Side Access Panel and Cover Once all water line conne...

Страница 7: ...rmal service or handling and to any products altered or repaired with other than original equipment or manufacturer s parts This warranty gives you specific legal rights and you may also have other ri...

Страница 8: ...of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between casing and concrete floor Valve won t stop drippi...

Страница 9: ...kg Optional 1 PKG 18320 O Ring Fenwal 6 pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 15154 Screw 1 4 x5 8 TC SS 10 pkg 1...

Страница 10: ...kg Optional 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 15154 Screw 1 4 x5 8 TC SS 10 pkg 1...

Страница 11: ...11515 Valve Bracket 1 2 w screws 1 pkg 9 18114 Trough Bolt Nut 5 pkg 1 pkg 28 12575 Red Valve 1 2 1 pkg 10 18628 Drain Plug 2 pkg 1 pkg 29 13613 Float with Short Arm 1 pkg 11 11419 Heater 120V 250W 1...

Страница 12: ...Optional 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 15158 J Bolt Nut ZP 10 pkg 1 pkg NS 18323 2AC Accessory pkg 1 pkg 9 17500 Drain Pipe Guard 1 NS 15652 2AC Ca...

Страница 13: ...2 pkg Optional 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 15158 J Bolt Nut ZP 10 pkg 1 pkg NS 18323 2AC Accessory pkg 1 pkg 9 17500 Drain Pipe Guard 1 NS 18059 2...

Страница 14: ...Htr 120V 48W 1 pkg 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 18323 1AC Accessory pkg 1 pkg 8 15158 J Bolt Nut ZP 10 pkg 1 pkg NS 15651 1AC Casing Insulation pkg 1 plg 10 18628 Drain Plug 2 pkg 1 pkg...

Страница 15: ...Fountain Model Part Hole to Hole Location 3 Cattle Fountain 16743 15 1 2 x 30 5 Cattle Fountain 16745 18 1 8 x 38 1 2 3 Combination Fountain 16769 15 1 2 x 30 1 AC 18034 8 1 2 x 18 2 AC 18033 8 7 16...

Отзывы: