Model: RWT6G
Installation
instructions
1 General Description
The Wireless VITRON is an advanced microprocessor based Acoustic
Glassbreak detector that detects the breaking of most common types of
framed glass panes while ignoring false alarms.
Main Features
Up to 9m detection range
Suitable for most common glass types: plate, tempered, laminated and
wired glass
Minimum size for all types of glass: 30cm x 30cm (12'' x 12'').
Wall and Front cover Tamper protection
Type of glass
Thickness
Plate
Tempered
Laminated
3.2 mm – 6.4mm
(1/8''-1/4'')
Wired
6.4 mm (1/4'')
Wireless VITRON will not alarm if glass pane is broken from inside or
glass is dropped on floor.
Optional ceiling/wall mount swivel adaptor for optimal mounting and
performance (supplied with the Wireless VITRON).
2 Installation Procedure
Wireless VITRON range of coverage depends on the type of glass (see
Table 1) and the installation angle between the Wireless VITRON and the
glass (see Fig 1).
Plate
Tempered, Laminated, Wired
Size Thickness
Max.
Range
Size Thickness Max.
Range
Minimum
50x50cm
(20"x20")
3.2 – 6.4mm
(1/8''-1/4'')
9m (30ft)
Minimum
30x30cm
(12''x12'')
6.4mm (1/4'')
6m
(20ft)
Minimum
30x30cm
(12''x12'')
6m (20ft)
Table 1
: Wireless VITRON range of coverage
Angle (degrees)
Percent of maximum range
0 10
12 95
30 87
45 70
60 50
75 25
90 0
Note:
To improve detection, It is highly recommended to use a swivel
adaptor, especially for ceiling and wall installations.
Fig 1
:
Percentage of Maximum
Range as a function of angle
between Wireless VITRON and
glass.
Verify that the distance between the Wireless VITRON and the furthest point
on the protected glass does not exceed the maximum specified range taking
into account the reduced range due to angle (see Fig 2).
Fig 2:
Angle between Wireless
VITRON and glass
Other factors affecting range:
There should be no obstructions between the Wireless VITRON and the
protected glass.
Curtains and blinds may reduce the effective range.
Sound absorbing materials in the protected area may reduce the range.
3 Mounting Location
For optimal performance the Wireless VITRON should be mounted as nearly
opposite to the glass area to be protected, as shown in Fig 3.
Attach the Glassbreak detector to the surface using the adhesive strips.
Fig. 3
Opposite Wall –Mounted
(For optimal
results, Wireless VITRON is centered
opposite glass, see Fig. 3).
Fig. 4
Ceiling Mounted
(for optimal results
Wireless VITRON is centered and directed
towards protected glass, using the supplied
swivel adaptor, see fig. 4)
Fig. 5
Corner Mounted
(choose corner opposite
glass to be protected, see fig. 5)
Fig. 6
Side wall
–
mounted
not recommended
due to the fact that the Wireless VITRON is
not opposite the glass - see range versus
angle diagram (Fig 2).
Notes:
1. Do not mount Wireless VITRON on same wall as the protected glass.
2. Avoid installing the Wireless VITRON near sources of loud noise or
vibrations (air conditioners, fans, compressors, stereos, etc).
3. Avoid defining the Wireless VITRON as a 24 hour zone.
4. The Wireless VITRON should always be installed in addition to standard
motion detectors.
4 Mounting
Fig. 7:
Opening the
detector cover
1. Open the Wireless VITRON cover using
a flat screwdriver.
2. Open the required mounting knockouts,
according to the type of installation (corner,
flat or swivel mounting, see Fig. 8).
3. Use the detector's back plate as a
template and mark the drilling holes on
the required position.
Note:
Remove the PCB only if corner mounting or optional swivel mounting
adaptor is used.
Fig 8
:
Wireless VITRON Mounting Knockouts
# Description
Corner mounting
knockout
Wall/Flat mounting
knockout
Back tamper
knockout
Swivel mounting
adaptor knockouts
Cover attaching
notches
Snap and fastening
screw
3. If a back tamper protection is required open the back tamper knockout
(3, Fig.8).
4. Secure the back plate to the wall using the supplied screws. Snap back
the PCB (if removed).
5. Insert battery in place according to the correct polarity (polarity marks –
on PCB).
5 Swivel Mounting
When installing the Wireless
VITRON with the supplied swivel
mounting adaptor, maximum
installation flexibility and
performance is achieved.
To install the swivel mounting
adaptor perform the following:
1. Remove the PCB from the
Wireless VITRON back plate
2. Open the swivel mounting adaptor
knockouts.
3. Attach the swivel mounting
adaptor to the back plate using the
two supplied screws (1, Fig 9).
Fig
.
9: Swivel Mounting
4. Mount the Wireless VITRON on the required location (wall or ceiling) using
the supplied screws (2, Fig 9). Do not tighten the screws.
5. Adjust the detector so it will face the protected glass.
6. Tighten the bolts to the final torque.
6 PCB Main Components
Fig
.
10:
PCB Main Components
#
Description
PCB
Battery holding holders
J3 – RF Power selector
J4 – Time supervision selector
Front Cover tamper switch
Back Plate cover tamper switch
Microphone
Antenna
Indication LED
Positioning hole
7 Quick Device Allocation
The VITRON must identify itself to the WiComm Smart Hub. This can be
performed either using the RISCO Express Wizard
(www.riscocloud.com/express) by adding the extra sensor at the same time
of the Smart Hub system installation or later either by using the “Settings” on
the Web (www.riscocloud.com) or using the WiComm Smart Hub, as follows:
75°
60°
45°
30°
15°
0°
WIRELESS
VITRON
VITRON
VITRON
VITRON
VITRON
VITRON
VITRON
VI TRON
VITRON
VITRON
1
5
4
2
3
1
6
1
2
3
4
5
6
2
1
ANTENNA
SW2
SW1
J4
J3
BAT
T1
RF POWER
HIGH/LOW
SUPERVISION
15/65 Min.
©
RISCO
LED
2
6
5
7
10
8
3
1
9
4
1
2
3
4
5
6
7
8
9
10