1 General Description 

The Wireless VITRON is an advanced microprocessor based Acoustic 
Glassbreak detector that detects the breaking of most common types of 
framed glass panes while ignoring false alarms. 

Main Features 

  Up to 9m detection range 

  Suitable for most common glass types: plate, tempered, laminated and 

wired glass 

  Minimum size for all types of glass: 30cm x 30cm (12'' x 12''). 

  Wall and Front cover Tamper protection 

Type of glass 

Thickness 

Plate 
Tempered 
Laminated 

3.2 mm – 6.4mm 
(1/8''-1/4'') 

Wired 

6.4 mm (1/4'') 

  Wireless VITRON will not alarm if glass pane is broken from inside or 

glass is dropped on floor. 

  Optional ceiling/wall mount swivel adaptor for optimal mounting and 

performance (supplied with the Wireless VITRON). 

2 Installation Procedure 

Wireless VITRON range of coverage depends on the type of glass (see 
Table 1) and the installation angle between the Wireless VITRON and the 
glass (see Fig 1). 

Plate 

Tempered, Laminated, Wired 

Size Thickness 

Max. 

 

Range 

Size Thickness Max. 

 

Range 

Minimum 
50x50cm 
(20"x20") 

3.2 – 6.4mm 

(1/8''-1/4'') 

9m (30ft)

Minimum 
30x30cm 

(12''x12'') 

6.4mm (1/4'')

6m  

(20ft) 

Minimum 
30x30cm 

(12''x12'') 

6m (20ft)

Table 1

: Wireless VITRON range of coverage 

Angle (degrees) 

Percent of maximum range 

0 10 

12 95 
30 87 
45 70 
60 50 
75 25 
90 0 

Note:

 To improve detection, It is highly recommended to use a swivel 

adaptor, especially for ceiling and wall installations. 

Fig 1

Percentage of Maximum 

Range as a function of angle 
between Wireless VITRON and 
glass.

 

Verify that the distance between the Wireless VITRON and the furthest point 
on the protected glass does not exceed the maximum specified range taking 
into account the reduced range due to angle (see Fig 2). 

Fig 2:

 Angle between Wireless 

VITRON and glass 

Other factors affecting range: 

 

There should be no obstructions between the Wireless VITRON and the 
protected glass.

 

 

Curtains and blinds may reduce the effective range. 

 

Sound absorbing materials in the protected area may reduce the range. 

3 Mounting Location 

For optimal performance the Wireless VITRON should be mounted as nearly 
opposite to the glass area to be protected, as shown in Fig 3. 
Attach the Glassbreak detector to the surface using the adhesive strips. 

 

Fig. 3

 

 

Opposite Wall –Mounted

 (For optimal 

results, Wireless VITRON is centered 
opposite glass, see Fig. 3). 

 

Fig. 4

 

Ceiling Mounted

 (for optimal results 

Wireless VITRON is centered and directed 
towards protected glass, using the supplied 
swivel adaptor, see fig. 4)

 

 

Fig. 5

 

 

Corner Mounted

 (choose corner opposite 

glass to be protected, see fig. 5)

 

  

Fig. 6

 

 

Side wall

 –

 mounted

 not recommended 

due to the fact that the Wireless VITRON is 
not opposite the glass - see range versus 
angle diagram (Fig 2).

 

 

Notes: 

1. Do not mount Wireless VITRON on same wall as the protected glass.  
2. Avoid installing the Wireless VITRON near sources of loud noise or 

vibrations (air conditioners, fans, compressors, stereos, etc). 

3. Avoid defining the Wireless VITRON as a 24 hour zone. 
4. The Wireless VITRON should always be installed in addition to standard 

motion detectors. 

4 Mounting 

 

Fig. 7: 

Opening the 

detector cover

 

1. Open the Wireless VITRON cover using 

a flat screwdriver. 

2. Open the required mounting knockouts, 

according to the type of installation (corner, 
flat or swivel mounting, see Fig. 8). 

3. Use the detector's back plate as a 

template and mark the drilling holes on 
the required position.

 

Note:

 Remove the PCB only if corner mounting or optional swivel mounting 

adaptor is used. 

Fig 8

Wireless VITRON Mounting Knockouts

 

# Description 

Corner mounting 
knockout 
Wall/Flat mounting 
knockout 
Back tamper 
knockout 
Swivel mounting 
adaptor knockouts 
Cover attaching 
notches 
Snap and fastening 
screw 

3. If a back tamper protection is required open the back tamper knockout 

(3, Fig.8).

 

4. Secure the back plate to the wall using the supplied screws. Snap back 

the PCB (if removed). 

5. Insert battery in place according to the correct polarity (polarity marks – 

on PCB).

 

5 Swivel Mounting 

When installing the Wireless 
VITRON with the supplied swivel 
mounting adaptor, maximum 
installation flexibility and 
performance is achieved. 
To install the swivel mounting 

adaptor perform the following: 

1.  Remove the PCB from the 

Wireless VITRON back plate 

2.  Open the swivel mounting adaptor 

knockouts. 

3.  Attach the swivel mounting 

adaptor to the back plate using the 

two supplied screws (1, Fig 9).

 

 

Fig

9: Swivel Mounting

 

4.  Mount the Wireless VITRON on the required location (wall or ceiling) using 

the supplied screws (2, Fig 9). Do not tighten the screws.  

5.  Adjust the detector so it will face the protected glass.  
6.  Tighten the bolts to the final torque.

 

6 PCB Main Components 

Fig

10: 

PCB Main Components

 

#

Description 

PCB 
Battery holding holders 
J3 – RF Power selector 
J4 – Time supervision selector 
Front Cover tamper switch 
Back Plate cover tamper switch 
Microphone 
Antenna 
Indication LED 
Positioning hole 

7 Quick Device Allocation 

The VITRON must identify itself to the WiComm Smart Hub. This can be 
performed either using the RISCO Express Wizard 
(www.riscocloud.com/express) by adding the extra sensor at the same time 
of the Smart Hub system installation or later either by using the “Settings” on 
the Web (www.riscocloud.com) or using the WiComm Smart Hub, as follows: 

75°

60°

45°

30°

15°

WIRELESS

VITRON

 

VITRON

 

VITRON

VITRON

 

VITRON

VITRON

VITRON

VI TRON

 

VITRON

VITRON

1

5

4

2

3

1

6

1

2

3

4

5

6

2

1

ANTENNA

SW2

SW1

J4

J3

BAT
T1

RF POWER

HIGH/LOW

SUPERVISION

15/65 Min.

©

 RISCO

LED

2

6

5

7

10

8

3

1

9

4

1

2

3

4

5

6

7

8

9

10

Отзывы: