Chapter 7. Setting Guide for each Configuration
7.3.3
Serial Settings (Server)
After clicking Serial Settings among the Set Menus, set values as shown in
Figure 7-14. Ad-Hoc Mode Serial
and then
click the [Submit] button.
Figure 7-14. Ad-Hoc Mode Serial Settings (Server)
1. Set Interface to
RS232.
y
During the setting, set the serial interface of the device connected to the WiComm-1.
2. Set Operation Mode to
TCP Server.
3. Set Local Socket Port to
4001.
y
This port is required for the access of the WiComm-1 set in Client mode.
4. Set Baud Rate to
9600bps.
5. Set Data Bits to
8Bit.
6. Set Stop Bits to 1
Bit.
7. Set Parity to
None.
8. Set Flow Control to
None.
9. Set Device Type to
Data Only.
10. Set MTU to ‘
1’.
7-14