Step 4
:
Using the extra relay zone input on the iWISE/BWarebus detectors:
To use the input of the iWISE/BWare detector you need to link it to one of the zones in the system that is not a bus
Zone detector.
1.
P (only):
From the main Installer menu select [2] Zones > [1] One by One. The following display
appears:
ZONE ONE BY ONE
ZONE = 001 (X:YY)
2.
P (only):
Select the zone number that you want to assign to the input.
Note: Do not select a zone number whose designation (x:yy) has already been assigned to a bus detector.
3.
Define Partitions, Groups, Zone Type and Zone Sound
4.
In the Termination category, select the relevant bus zone input termination:
BUS Zone Input N/C
BUS Zone Input EOL
BUS Zone Input DEOL
BUS Zone Input N/O
BUS Zone Input TEOL
5.
Press
/
. Select the bus zone that the input zone belongs to. The
Type
field will be updated
automatically when selecting the zone.
Press
/
. Define the loop response time.
6.
Press
/
, assign a label and press
/
.
Step 5: Setting the Bus Detectors Parameters
1.
From the main Installer menu select:
P
: [2] Zones > [0] Miscellaneous > [3] BUS Zone Parameters.
L
:
Zones
Parameters
By Category
Advanced
Bus Zone Configuration
2.
Select the zone that the BUS Zone was assigned to and press
/
.
3.
Configure the parameters for the relevant bus detector.
Technical Specifications:
Power Supply: 13.8V
Current Consumption: 20mA
Dimension: 10.5 cm x 6.6 cm x 1.8 cm
Main Panel Connection: 4-wire bus, up to 300 m from Main Panel
Certification:
EN 50131-3, Grade 2 and Environmental Class II
EN50131-3 Grade 3 Environmental class II (For Grade 3 installation using ProSYS Plus panel model RP512M)