Installing Bus Devices
Page
39
7.
Wire the wireless expander to the bus.
8.
Connect the devices to the outputs terminals (12VDC @ 1A max Dry Contact
Relays). See Figure
9.
Mount the wireless receiver to the mounting bracket.
10.
Close the mounting screw
11.
Close the front cover. Use the screw cap you tore on Step 3 on the rear side.
Note:
For additional programming and configuration instructions, see 5IN1424 Wireless
Receiver 432 Installation instructions
3A Switching Mode Power Supply
Figure
3-8: SMPS –General View
To mount the 3A Switching Mode Power Supply (SMPS)
1.
Mount the SMPS and the backup battery inside a metal box.
Important:
The SMPS should be serviced by qualified personnel only!
Unless serviced, the SMPS box must be closed with screws at all times!
Use only safety-approved wires in accordance with the national rules.
The SMPS is designed for indoor use only!