Mounting and Wiring
Page
31
Position
Function
DIP switches
ON
1
2
3
4
Factory
Default
DIP Switch SW1
Status
1: Bell
ON
: Bell: For bell or electronic sounder with a built-in sounder
driver.
OFF
(Default): For loudspeaker without a built-in sound driver.
2: Default
ON
: Resets engineer, sub-engineer and grand master codes to
their default factory values and omits main unit front tamper
alarm.
OFF
(Default): Codes preserve their set values.
3: For future use
4: Back Tamper
Omission
ON
: Back tamper omit is in effect. Use this setting during
programming and if no back tamper has been connected to
PLUG 2.
OFF
(Default): No tamper omit is in effect. Use this option when
back tamper is connected to the system
Connecting Backup Battery
Insert the backup battery into its place and connect the leads to the main panel battery,
PLUG7 (p. 30).
Notes:
The main panel is designed to work with an approved 12 VDC, 7 Amp-hour
sealed lead battery as a backup for the primary power supply in time of main
power failure.
The main panel is designed with reverse polarity protection on the battery
charging circuit. However, prolonged improper connection of the battery to the
main panel will result in damage.
The battery is not supplied with the LightSYS.
The LightSYS Rechargeable battery should be charged for at least 24 hours.
Battery is checked every 1 minute.
There is a risk of explosion if a battery is replaced with an incorrect type.
Dispose of used batteries according to the proper instructions.
Battery in product shall be replaced every 3-5 years. No maintenance is needed
.
The power should remain disconnected until all connections have been made
and checked for accuracy
Use the internal jumper (Jumper 1) to configure battery discharge protection. See
page 30.