Mounting and Wiring
Page 30
PLUG 6
Use this outlet for connection to the RISCO supplied
certified AC to DC adaptor.
Note
: the Adaptor outgoing power cord can be cut for
the plug and attached to the supplied terminal block
fuse (See Figure
2-3) as per your local wiring
requirements.
Additionally, input wiring can also be connected to
LightSYS through the neighboring (–) and (+) terminal
block connectors.
PLUG 7
Battery
Use this outlet to connect to the backup battery (not-
supplied), of 12 volts and 7Ah
Jumpers
The LightSYS is equipped with an internal jumper to configure battery discharge
protection. Use the following table to set the jumper.
Position
Function
(Default)
Battery Discharge Protection is disabled; The battery may be
totally discharged during continuous AC failure, thus battery
replacement may be required (no deep discharge protection).
Note:
In this position, the LightSYS will start to operate from a battery
power supply whether it is connected to the Mains or not.
Battery discharge protection is activated: If a continuous AC
power outage occurs, the LightSYS automatically disconnects
the battery when its backup battery voltage drops below 10.05
VDC, in order to prevent "deep discharge” that may damage the
battery.
Note:
In this position, the LightSYS will not start to operate from a
battery power supply, unless connected to the Mains first.