Mounting and Wiring
Page
29
Plug-in Fast Modem 2400
To activate the Plug in Fast Modem 2400 Module
Place the optional Fast communication modem (mounted on its placement struts)
as illustrated in Figure
Figure
2-12 Placing the Fast
communication modem
Figure
2-13 Placing the battery and
attaching the plug
Main Unit DIP Switch and Jumper Setting
Plugs
Plug
Description
Function
PLUG 1
Bus Connector
Bus 4 pin plug for easy connection to the bus
PLUG 2
Back Tamper
Used for the connection of the optional back tamper
PLUG 3
Telephone
Used for a local telephone connection (same as the
PHONE SET terminal)
PLUG 4
Voice
Used to connect the Advanced Digital Voice
Module (RP432EV) to the LightSYS.
Connect the Voice module to the VOICE connector
(PLUG 4) on the main panel via the supplied cable. This
connector transmits signals from the voice module to
the telephone line during remote communication and is
essential for normal operation of the voice module.
PLUG 5
RS-232
Used for local communication with the configuration
software.
Содержание LightSYS