Engineer Programming
Page 126
5 Communication
The Communication menu provides access to submenus and their related parameters that
enable the system to establish communication with the alarm receiving centre, Follow Me or
Configuration Software.
The Communication menu is divided into the following sub-menus:
Method, page 126
Alarm Receiving Centre (ARC), page 137
Configuration Software, page 147
Follow Me, page 150
Method
This option allows you to configure the parameters of the communication methods
(channels) of the LightSYS, with three available communication types:
PSTN
GSM
IP
Radio (Long Range radio)
PSTN
Quick Keys
Parameter
Default
Range
PSTN
The PSTN screens contains parameters for the communication of the
LightSYS over the PSTN network.
Timers
Timers related to communication through the PSTN channel
PSTN Lost Delay
4 minutes
0–20 minutes
The time after which the system will regard the PSTN line as lost. This
time also specifies the delay before reporting the event into the event log
or operating a programmable output that follows this event.
00 indicates no supervision of the phone line.
Wait for Dial Tone
3
0–255 seconds
The number of seconds the system waits to detect a dial tone.
Содержание LightSYS