Engineer Programming
Page
121
Quick Keys
Parameter
Default
Range
Latch N/O
05 seconds
01-90 seconds
The programmable output is always deactivated (N/O) before it is
triggered (pulled up).
When triggered, it activates (is pulled down) and remains activated
(latched) until the operation is restored.
1.
Press
and then press
.
2.
Using the
key select ALL or ANY to set the activation and
press
.
3.
Using the
key select ALL or ANY to set the deactivation
and press
.
4.
Define the output label and press
Note
You can create and/or edit a ten-character label description for each
programmable output. See page 80, for additional details
Programmable output; Activation/Deactivation
When the programmable output is following more than one partition or zone, the engineer
can choose the logic of the programmable output activation or deactivation, as follows:
If the Pattern of Operation is defined as Latch N/O or Latch N/C, the Engineer can
choose the activation and deactivation logic of the PO to follow either after all the
Partitions/Zones or after any of the Partitions/Zones.
If the Pattern of Operation is defined as Pulse N/O or Pulse N/C, the Engineer can
choose only the activation logic of the programmable output to follow either after all the
Partitions/Zones or after any of the Partitions/Zones. The deactivation operation follows
the defined time period.
4 Codes
The Codes menu provides access to submenus and their related parameters that enable you
to maintain the User Codes in the system
In addition, the LightSYS contains the following special codes:
Grand Master Code: Used by the system's owner or chief user.
Engineer Code: Used by the LightSYS installation company technician to program the
main panel.
Sub-Engineer Code: Used by a technician sent by the LightSYS installation company to
carry out restricted tasks defined at the time of system installation by the installation