Engineer Programming
Page
105
Quick Keys
Parameter
Default
Range
ZZ
Green Line
Yes
This feature defines the activation of the microwave channel while the
system is unset.
NO
- Green Line feature is disabled. MW is constantly activated.
YES
- Green Line feature is enabled. This option conforms to
environmentally friendly standards by avoiding surplus emission.
ZZ
Sway
No
This option allows the recognition and immunity of swaying objects in
a known pattern.
NO
- Sway is disabled.
YES
- Sway is enabled.
ZZ
Wireless Zone Parameters - Supervision
Choose which zone will be supervised by the system receiver according
to the time defined under the timer RX Supervision. (See
)
Resistance
In the LightSYS you have the ability to define separately the end-of-line
resistance of the zones on the main unit
Selection is done by the software with the following available options
Specify here the optional circuit resistance configuration.
Custom
2.2K; 2.2K
4.7K; 6.8K
6.8K; 2.2K
10K; 10K
3.74K; 6.98K
2.7K; 2.7K
4.7K; 4.7K
3.3K; 4.7K
1K; 1K
3.3K; 3.3K
5.6K; 5.6K
2.2K; 1.1K
2.2K; 4.7K
Testing
The following menu is used to perform tests on the system. Note that each test refers to the
last time the device was activated. Tests can be performed on the following elements: