13
PROGRAM SELECT
User Settings
ON
To avoid an erroneous setting by the user, the charger will automatically detect the cell count
of a Lithium battery at the beginning of the charge process. To prevent an
over discharged battery from being detected incorrectly, resulting in an error, you can set a
time limit for the processor to verify the cell count. The default setting is 5 minutes which is
typically enough time to properly detect the cell count. For batteries of a larger capacity, you
may extend the time, and for the batteries of a smaller capacity, you may reduce the time or
use with the default value.
This setting is for NiMH batteries only. This screen allows you to set the delta peak
detect settings between 5mV and 25mV per cell. The default is set at 10mV, suiting most
applications.
This setting is for NiCd batteries only. This screen allows you to set the delta peak
detect settings between 5mV and 25mV per cell. The default is set at 10mV, suiting most
applications.
The screen shows the cut-off temperature of a battery. You can press “the button” or “the
button” to select the cut-off temperature (Temp. Range: 0~90°C). The maximum temperature
of the battery can be set during the charge process. The process will be terminated
automatically to protect battery once the temperature of battery reaches this value. This
feature is accomplished through a temperature probe (optional).