How to append a “prefix” or a “suffix” to the 
barcode data 

 

 

 

prefix 

 suffix 

 

1.

 

scan above configuration code for Prefix or Suffix 

2.

 

enter the required values (right, numeric barcode) for Prefix or Suffix 
using the hex values for the desired HEX values from Prefix & Suffix 
TABLE (below page)” 

3.

 

then, end by scanning Code X (below, right) 

 
*

 

The max. of special characters is 5. 

*

 

When you append 1~4 required values for Prefix or Suffix, it must end 
with Code X. 

*

 

It doesn’t need Code X, if you append 5 values to barcode data. 

 

How to delete Prefix or Suffix 

1.

 

scan above configuration code for Prefix or Suffix 

2.

 

enter the “0” “0” (above, left) 

3.

 

then end by scanning Code X (below, right) 

 

Numeric barcode for settings 

 

0

 

6

 

C

1

 

7

 

D

2

 

8

 

E

3

 

9

 

F

4

 

A

 

 

5

 

B

 

X

 

 

Prefix & Suffix TABLE 

 

HEX

HID

(SPP) 

HEX

HID

(SPP) HEX

 HEX

 

HEX  HEX

01

CTRL A

(SOH)

19 CTRL Y

(EM)

20

SPACE 38

8 50 P

68

h

02

CTRL B

(STX) 

1A

CTRL 

Z(SUB) 21

39

9  51  Q

69

i

03

CTRL C

(ETX) 

1B

ESC

(ESC)

22

" 3A

52 

R

6A

j

04

CTRL D

(EOT) 

1C

CTRL \

(FS)

23

3B

;  53  S

6B

k

05

CTRL E

(ENQ)

1D

CTRL ]

(GS)

24

$ 3C

54 

T

6C

l

06

CTRL F

(ACK) 

1E

CTRL ^

(RS)

25

3D

=  55  U

6D m

07

CTRL G

(BEL) 

1F

CTRL _

(US)

26

& 3E

56 

V

6E

n

08

Backspace

(BS) 

27

3F

?  57  W

6F

o

09

Tab

(HT) 

HEX

HID 

Only

28

( 40

58 

X

70

p

0A

CTRL J

(LF) 

80

F1 

29

41

A  59  Y

71

q

0B

CTRL K

(VT) 

81

F2 2A

*  42

5A 

Z

72

r

0C

CTRL L

(FF) 

82

F3 

2B

43

C  5B  [

73

s

0D

Enter

(CR) 

83

F4 2C

,  44

5C 

\

74

t

0E

CTRL N

(SO) 

84

F5 

2D

45

E  5D  ]

75

u

0F

CTRL O

(SI) 

85

F6 2E

.  46

5E 

^

76

v

10

CTRL P

(DLE) 

86

F7 

2F

47

G  5F  _

77

w

11

CTRL Q

(DC1) 

87

F8 30

0  48

60 

`

78

x

12

CTRL R

(DC2) 

88

F9 

31

49

I  61  a

79

y

13

CTRL S

(DC3) 

89

F10

32

2 4A

62 

b

7A

z

14

CTRL T

(DC4) 

8A

F11

33

4B

K  63  c

7B

{

15

CTRL U

(NAK) 

8B

F12

34

4 4C

64 

d

7C

|

16

CTRL V

(SYN) 

35

4D

M  65  e

7D

}

17

CTRL W

(ETB) 

36

6 4E

66 

f

7E

~

18

CTRL X

(CAN) 

37

4F

O  67  g

 

 

Barcode Configuration Method: 

(Flow chart for setup procedure :

 

 

 

Start 

Configuration 

End  

Configuration 

 

 

 

1D Symbologies – 1 

 

ENABLE 

 

CODE 39 

DISABLE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENABLE 

CODE 39 Transmit 

Start/Stop Character

DISABLE 

 

 

 

ENABLE 

CODE 39 

FULL ASCII 

 

DISABLE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENABLE 

 

EAN-8 

DISABLE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENABLE 

 

EAN-13 

DISABLE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENABLE 

 

CODE 11 

DISABLE 

 
 

 

 

 

Содержание iDC9507A

Страница 1: ...safety information If you do not follow the safety instructions and information on proper handling in this manual we assume no liability for any resulting personal injury or damage to property Don t put scanner in places excessively high temperatures such as expose under direct sunlight Don t use scanner in extremely humid area or drastic temperature change The rechargeable battery is permanently ...

Страница 2: ...shuts down it is recommended to charge it fully before turning it back on Under power saving mode there will not be LED indication when charging Reset Configuration to Defaults scan from A1 to A8 for HID profile or B1 to B8 for SPP profile HID profile SPP profile A1 B1 A2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 A8 B8 There are two operating modes on the scanner 1 Data Transmission mode Default It is a ne...

Страница 3: ...mm 20yy For example 23 01 2011 Date format 3 20yy mm dd For example 2011 01 23 The punctuation marks for the intervals among barcode data date time comma default FOR Android iOS use For example ABCD 01 23 2011 12 34 56 Tab FOR iOS use For example ABCD 01 23 2011 12 34 56 semicolon FOR Android iOS use For example ABCD 01 23 2011 12 34 56 Date and Time setting SET DATE Scan the SET DATE barcode then...

Страница 4: ...SC ESC 22 3A 52 R 6A j 04 CTRL D EOT 1C CTRL FS 23 3B 53 S 6B k 05 CTRL E ENQ 1D CTRL GS 24 3C 54 T 6C l 06 CTRL F ACK 1E CTRL RS 25 3D 55 U 6D m 07 CTRL G BEL 1F CTRL _ US 26 3E 56 V 6E n 08 Backspace BS 27 3F 57 W 6F o 09 Tab HT HEX HID Only 28 40 58 X 70 p 0A CTRL J LF 80 F1 29 41 A 59 Y 71 q 0B CTRL K VT 81 F2 2A 42 B 5A Z 72 r 0C CTRL L FF 82 F3 2B 43 C 5B 73 s 0D Enter CR 83 F4 2C 44 D 5C 74...

Страница 5: ...BLE GS1 Databar RSS Limited DISABLE ENABLE GS1 Databar RSS Expand DISABLE ENABLE CODE 128 DISABLE ENABLE GS1 128 UCC EAN 128 DISABLE ENABLE CODE 93 DISABLE ENABLE Industrial 25 DISABLE ENABLE CODABAR DISABLE ENABLE MSI DISABLE 1 Pull out the USB cover its slot 2 Press inward firmly on the USB cover to reattach it Top Bottom Insert a thin object e g a bent paper clip into the small hole To click th...

Отзывы: