RIOTEC iDC9277A Скачать руководство пользователя страница 4

 

 

Date and Time setting 

 

 

                                            

 

SET DATE 

Scan the SET DATE barcode, then, scan the six 

numeric digits in the format mm/dd/yy, from the 

numeric barcode. 

For example: “01/23/2011”, please input 

012311 

 

 

 

                                           

 

 

SET TIME 

Scan the SET TIME barcode, then, scan the six 

numeric digits in the format hh:mm:ss from the 

numeric barcode. Time format: 24hr clock 

For example: “PM 3:25:30”, please input 

“152530” 

 

Keyboard Country 

(For HID profile only)

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scan the appropriate country code as below 

to program the keyboard layout for your 

country or language. As a general rule, the 

following characters are supported, but need 

special care for countries other than the 

United States: 

@ | $ # { } [ ] = / ‘ \ < > ~ 

 

Follow the steps mentioned below to program. 

1.

 

Keyboard Country setting code.   

2.

 

“Select Country Code”   

 

Read numeric barcode (according to country code). 

 

Country/ 

Language 

No. 

Country/ 

Language 

No. 

Country/ 

Language 

No. 

U.S. 

10 

Netherlands 

26 

Switzerland 

French 

45 

Latin 

America 

11 

Hungary 

27 

Switzerland 

German 

46 

Brazil 

12 

Italian 

28 

Sweden 

47 

Belgium   

20 

Icelandic 

29 

Turkey F 

48 

Bulgarian 

Latin 

21 

Norway 

30 

Turkey Q 

49 

Denmark 

22 

Poland 

41 

Japan 

71 

Finland 

23 

Portugal 

42 

Korea 

72 

France 

24 

Russia 

43 

Thai 

73 

Germany 

25 

Spain 

44 

Vietnam 

74 

 

 

 

How to append a “prefix” or a “suffix” to the 

barcode data 

 

 

                                             

 

 

 

 

                                             

 

 

prefix 

 

suffix 

 

1.

 

scan above configuration code for Prefix or Suffix 

2.

 

enter the required values (right, numeric barcode) for Prefix or Suffix 

using the hex values for the desired HEX values from Prefix & Suffix 

TABLE (below page)” 

3.

 

then, end by scanning Code X (below, right) 

 

*

 

The max. of special characters is 5. 

*

 

When you append 1~4 required values for Prefix or Suffix, it must end 

with Code X. 

*

 

It doesn’t need Code X, if you append 5 values to barcode data. 

 

How to delete Prefix or Suffix 

1.

 

scan above configuration code for Prefix or Suffix 

2.

 

enter the “0” “0” (above, left) 

3.

 

then end by scanning Code X (below, right) 

 

Numeric barcode for settings 

 

 

                   

 

0

 

 

                    

 

6

 

 

                    

 

C

 

 

                   

 

1

 

 

                    

 

7

 

 

                    

 

D

 

 

                    

 

2

 

 

                    

 

8

 

 

                    

 

E

 

 

                    

 

3

 

 

                   

 

9

 

 

                    

F

 

 

                   

 

4

 

 

                    

 

A

 

 

 

                   

 

5

 

 

                    

 

B

 

 

                   

 

X

 

 

 

Prefix & Suffix TABLE 

 

HEX 

HID 

(SPP) 

HEX  HID 

(SPP)  HEX 

 

HEX    HEX    HEX   

01 

CTRL A 

(SOH) 

19  CTRL Y 

(EM) 

20  SPACE  38  8  50  P  68  h 

02 

CTRL B 

(STX) 

1A  CTRL 

Z(SUB)  21 

39  9  51  Q  69 

03 

CTRL C 

(ETX) 

1B 

ESC 

(ESC)  22 

3A  :  52  R  6A  j 

04 

CTRL D 

(EOT) 

1C  CTRL \ 

(FS) 

23 

3B  ;  53  S  6B  k 

05 

CTRL E 

(ENQ) 

1D  CTRL ] 

(GS) 

24 

3C  <  54  T  6C  l 

06 

CTRL F 

(ACK) 

1E  CTRL ^ 

(RS) 

25 

3D  =  55  U  6D  m 

07 

CTRL G 

(BEL) 

1F  CTRL _ 

(US) 

26 

3E  >  56  V  6E  n 

08  Backspace 

(BS) 

 

 

27 

3F  ?  57  W  6F  o 

09 

Tab 

(HT) 

HEX  HID   

Only 

28 

40  @  58  X  70  p 

0A 

CTRL J 

(LF) 

80 

F1 

29 

41  A  59  Y  71  q 

0B 

CTRL K 

(VT) 

81 

F2 

2A 

42  B  5A  Z  72  r 

0C 

CTRL L 

(FF) 

82 

F3 

2B 

43  C  5B  [  73  s 

0D 

Enter 

(CR) 

83 

F4 

2C 

44  D  5C  \  74  t 

0E 

CTRL N 

(SO) 

84 

F5 

2D 

45  E  5D  ]  75  u 

0F 

CTRL O 

(SI) 

85 

F6 

2E 

46  F  5E  ^  76  v 

10 

CTRL P 

(DLE) 

86 

F7 

2F 

47  G  5F  _  77  w 

11 

CTRL Q 

(DC1) 

87 

F8 

30 

48  H  60  `  78  x 

12 

CTRL R 

(DC2) 

88 

F9 

31 

49  I  61  a  79  y 

13 

CTRL S 

(DC3) 

89 

F10 

32 

4A  J  62  b  7A  z 

14 

CTRL T 

(DC4) 

8A 

F11 

33 

4B  K  63  c  7B  { 

15 

CTRL U 

(NAK) 

8B 

F12 

34 

4C  L  64  d  7C  | 

16 

CTRL V 

(SYN) 

 

 

35 

4D  M  65  e  7D  } 

17  CTRL W 

(ETB) 

 

 

36 

4E  N  66  f  7E  ~ 

18 

CTRL X 

(CAN) 

 

 

37 

4F  O  67  g 

 

 

 

 

Содержание iDC9277A

Страница 1: ...ase press Left button Right button Touch trigger for 8 9 seconds to activate iDC9277A The touch sensor area is around the central area Please check the above drawing for your reference LED Indicator Information Orange LED ON Full charged Orange and Red LED Flashing Charging Orange LED Flashing Low battery Red LED ON Off line out of service Green LED ON Good read Orange LED ON Good read Batch mode ...

Страница 2: ...roid system if you want to raise lower soft keyboard please read the above setting code first Then press left button refer to drawing 5 on page 1 to raise keyboard LED is RED Bluetooth is offline press it again to lower keyboard LED is off Bluetooth is online It will take 5 10 seconds to make BT online offline Please be noted that when BT is offline scanning function is stopped Or switch C to O to...

Страница 3: ...ault Trigger available after data sent to the device Transmission Speed Transmission speed is dependent on your device In order not to lose data please choose the correct speed Middle speed is the Default High speed Ultra Slow speed transmission 1 transmission Middle speed Ultra Slow speed transmission 2 transmission Slow speed Ultra Slow speed transmission Default 3 transmission Power saving Mode...

Страница 4: ...arcode for Prefix or Suffix using the hex values for the desired HEX values from Prefix Suffix TABLE below page 3 then end by scanning Code X below right The max of special characters is 5 When you append 1 4 required values for Prefix or Suffix it must end with Code X It doesn t need Code X if you append 5 values to barcode data How to delete Prefix or Suffix 1 scan above configuration code for P...

Страница 5: ...E ENABLE UPC A DISABLE ENABLE Interleaved 25 DISABLE ENABLE Matrix 25 DISABLE ENABLE EAN 8 DISABLE ENABLE EAN 13 DISABLE ENABLE MSI DISABLE 1D Symbologies 3 ENABLE GS1 Databar RSS DISABLE ENABLE GS1 Databar RSS Limited DISABLE ENABLE GS1 Databar RSS Expand DISABLE ENABLE CODE 128 DISABLE ENABLE GS1 128 UCC EAN 128 DISABLE ENABLE CODE 93 DISABLE ENABLE Industrial 25 DISABLE ENABLE CODABAR DISABLE I...

Отзывы: