RIOTEC iDC9273A Скачать руководство пользователя страница 3

 

 

There are two operating modes on the scanner

   

 

 

1.Data Transmission mode 

(Default)

 

 

 

 

It is a necessary to scan “clean memory data" when 

switching between these two modes.

 

 

Within Bluetooth radio 

range

 

Beyond  Bluetooth radio  range

Data 

read 

Transmit data to PC/terminal 

directly 

Save data into scanner’s memory, 

scanner will transmit data to PC/ 

terminal automatically when back to 

Bluetooth radio range. 

 

Enter Data Storage mode

 

LED  Green/ Orange LED flashes 

followed by 3 beeps. 

 

 

 

2.Data Storage mode 

(Batch Mode)

 

 

 

 

It is a necessary to scan “clean memory data" when switching 

between these two modes.

 

Data 

read 

Save data directly to scanner’s memory, It will transmit the data to PC/ 

terminal after you scan the 

Transmit memory data 

code. To delete 

data please scan the 

Clean memory data

 code.

 

 

Enter Data Transmission mode

 

LED  Green/Orange LED flashes followed by 3 beeps.

 

 

Always 

Clean memory data

before switching to Data Transmission 

Mode. Otherwise Red/ Orange LED will flash with one long beep and 

will not switch modes. 

 

Under Data storage Mode 

The data can be keep or delete by option after transmit 

 

 

Keep the data 

(Default) 

Delete the data

 

 

Transmit memory data

Green/Orange LED Flashes followed by 3 beeps

 

 

 

Clean memory data 

Green/Orange LED flashes followed by 3 beeps 

The barcode data which is stored in the memory will be deleted. 

 

 

Trigger Mode 

 

Trigger always 
(Trigger available at any time)

 

 

 

Trigger standard 

(Default)

 

(Trigger available, after data sent to the device)

 

Transmission Speed 

Transmission speed is dependent on your device. In order not to lose data, 
please choose the correct speed. Middle-speed is the Default. 

 

 

High-speed 

 

Ultra Slow-speed

 

transmission

 

1

 transmission

 

Middle-speed 

 

Ultra Slow-speed 

transmission 

 

2

 transmission 

 

Slow-speed

 

 

Ultra Slow-speed

transmission

(Default)

 

 

3

 transmission

 

Power-saving Mode 

 

Power-saving mode OFF 

Power-saving mode ON 

(Default)

Enter power-saving mode after 5-minute 
inactivity. This function converses battery 

power. When you press "SCAN/Power ON" 
button, it will wake up and begin to scan. 

Power-saving mode ON:   
Enter power-saving mode after 10-minute 
inactivity. This function converses battery 
power. When you press "SCAN/Power ON" 
button, it will wake up and begin to scan. 

 

*

 

When charging, the scanner will not enter power-saving mode 
automatically.

 

 

RTC (Real-time clock), 

please set the punctuation mark at the same time 

You must scan the below configuration barcode to set the date & time 
stamp on the scanner. 

 

 

Date information:

ENABLE 

 

Date information: 

DISABLE 

(default)

 

 

Time information:

ENABLE 

Time information: 

DISABLE 

(default)

 

 

The format of Date setting 

 

Date format 1: mm/dd/20yy 

(default)

 

For example: 01/23/2011 

 

 
 

Date format 2: dd/mm/20yy 

For example: 23/01/2011 

 

 
 

Date format 3: 20yy/mm/dd 
For example: 2011/01/23 

 

The punctuation marks for the intervals among 
barcode data, date, time 

 

, comma 

(default)

– FOR Android/iOS use 

For example: 
ABCD,01/23/2011,12:34:56 

 

 
 

Tab – FOR iOS use
For example: 
ABCD 01/23/2011 12:34:56 

 

 
 

; semicolon – FOR Android/iOS use 
For example: 
ABCD;01/23/2011;12:34:56 

 

 

 

Содержание iDC9273A

Страница 1: ...ping mode Please press Left button Right button Touch trigger for 8 9 seconds to activate iDC9273A The touch sensor area is around the central area Please check the above drawing for your reference LED Indicator Information Orange LED ON Full charged Orange and Red LED Flashing Charging Orange LED Flashing Low battery Red LED ON Off line out of service Green LED ON Good read Orange LED ON Good rea...

Страница 2: ... 4 Turn it ON and search the Devices 5 Select Rxxxxxx to connect 6 When see the Connected means the connection is OK example pairing with iPhone Reset Configuration to Defaults scan from A1 to A3 for HID or B1 to B2 for RS232 USB Serial HID profile SPP profile A1 B1 A2 B2 A3 Soft Keyboard setting code for Android iOS For Android For iOS Under Android system if you want to raise lower soft keyboard...

Страница 3: ... Default Trigger available after data sent to the device Transmission Speed Transmission speed is dependent on your device In order not to lose data please choose the correct speed Middle speed is the Default High speed Ultra Slow speed transmission 1 transmission Middle speed Ultra Slow speed transmission 2 transmission Slow speed Ultra Slow speed transmission Default 3 transmission Power saving ...

Страница 4: ...arcode for Prefix or Suffix using the hex values for the desired HEX values from Prefix Suffix TABLE below page 3 then end by scanning Code X below right The max of special characters is 5 When you append 1 4 required values for Prefix or Suffix it must end with Code X It doesn t need Code X if you append 5 values to barcode data How to delete Prefix or Suffix 1 scan above configuration code for P...

Страница 5: ...BLE GS1 128 DISABLE ENABLE TELEPEN DISABLE ENABLE UPC A DISABLE ENABLE EAN 13 DISABLE ENABLE EAN 8 DISABLE 1D Symbologies 3 ENABLE GS1 Omnidirectional DISABLE ENABLE GS1 DataBar Limited DISABLE ENABLE GS1 DataBar Expanded DISABLE ENABLE CHINA POST DISABLE ENABLE PLESSY CODE DISABLE ENABLE INDUSTRIAL 25 DISABLE ENABLE IATA 25 DISABLE Information in this document is subject to change without notice ...

Отзывы: