Rio Grande Digital Temperature Controller Скачать руководство пользователя страница 10

Display Messages

The firing was stopped.

(Page 7) Ready for you to enter an alarm temperature.

When the kiln reaches that temperature, the alarm will sound.

During a User Defined firing, you can change the tar-

get temperature of a segment without having to first stop the

firing.

Fired to completion. If the kiln is already hotter than the

programmed target temperature when you begin firing,

will appear immediately after you begin firing.

(page 3) Delay is a count-down timer that starts the

kiln when the time runs out.

or

(and temperature) (page 6) The target

temperature (the temperature that the kiln will fire to). Each seg-

ment in a User Defined program has a target temperature.

Full power firing rate. At this setting the kiln will fire at

its fastest rate. To select Full power, select a rate of

1799°F/999°C at the

prompt in a User Defined program. A

fast way to do this is to press the

key once from

.

will appear.

(pages 5 & 6) Hold time of a segment, shown in hours

and minutes. (i.e. 2 hours 15 minutes = 02.15.)

(Page 7) During a User Defined firing, you can extend

the hold time to a segment without having to first stop the firing.

(page 3) The controller is ready for you to enter a pro-

gram or to begin a repeat firing.

Firing has begun. A moment after

appears, you

will hear the relay(s) clicking.

,

,

,

,

(page 4)

These are PMC programs stored in memory.

(User Defined Program) (page 5) Select this option to

program a custom firing.

,

, etc. (Rate) (page 6) This appears in User

Defined programming for each segment. 1, 2, etc. are segment

numbers. Enter the rate of temperature change for that seg-

ment. Rate is figured in degrees of temperature change per

hour. Example:
A temperature rise of 100° in two hours = 50° rate.

A temperature drop of 200° in one hour = 200° rate.

(Skip Step) (page 5) This message appears when you

press the

key during a User Defined firing. If you press

the

key again, the firing will skip to the next segment.

The firing was stopped by pressing

.

The "Ready to Start" message appears after program-

ming a firing. Press

to begin firing. Controller Calibration

(press the

) and Delay (press the

)

are accessed from the

message.

(Page 9) Calibrate the controller to fire hotter or

cooler.

Trouble Shooter

Problem: Controller display is blank.

No heat in kiln.

I

Is the kiln connected to the power?

I

Has the circuit breaker tripped or fuse blown?

I

Is power reaching the wall receptacle?

Test with a voltmeter or test light if you are not sure.

I

Has the kiln switch box ½ amp fuse blown?

The kiln’s ½ amp fuse is lo-

cated in the kiln switch box. Re-

move by pressing the fuse holder

and turning counter-clockwise

half a turn. Check the fuse by

placing the probes of an ohmme-

ter on the ends of the fuse. If the

ohmmeter reads less than an

ohm (digital meter) or reads 0

ohms (analog meter), the fuse is

okay. If the reading is OPEN (digital meter) or infinity/no

needle movement (analog meter), the fuse is bad. Replace-

ment fuse:

AGC 1/2 A 250V AC

I

Is the controller receiving power? Test the power IN-

PUT connections on the back of the controller with a

voltmeter.

Controller Power Input Test

Unplug the kiln. Remove the 4

screws holding the controller

faceplate to the switch box. Lift

faceplate out of box and let the

board hang on the box with the

back of the board facing you.

Plug the kiln back in. Touch volt-

meter probes (in AC mode) to

both INPUT connections (the

white and orange wires).

Caution:

Do not let the back of the board touch a

grounded object. Make sure the voltmeter is in the

AC mode when placing the probes on INPUT con-

nections.

Controller Power Input Test Result: No voltage

UNPLUG kiln. Check the switch box for disconnected

wires between the cord, transformer, and controller. If wir-

ing is okay, replace the transformer.

Controller Power Input Test Result: 20 - 24 volts AC

Correct current is reaching the board from the trans-

former. But since the board is not lighting up, it is probably

defective. Return the controller for repair or replacement.

Controller Power Input Test Result: less than 20 volts

Did you recently replace the transformer? It may be the

wrong voltage. The voltage is below 20, which is not enough

Содержание Digital Temperature Controller

Страница 1: ...row keys to change the target temperature for the cur rent segment Then press Page 6 During a firing press repeatedly until appears Press Use the arrow keys to change the alarm temperature Press To si...

Страница 2: ...code before appears then the controller includes only Skip Segment from Advanced Features on pages 6 7 If your controller shows a software code before appears then the controller has all the features...

Страница 3: ...highest number and vice versa Examples I To program a 99 59 hour Hold when the display shows 00 00 press the once I To program a FULL rate when the display shows 0000 press the once I To program a te...

Страница 4: ...g a cooling segment and the kiln cooled past the target temperature while the power was off The power failed during firing and kiln tempera turewasbelow212 F 100 Cwhenthepowercamebackon The power fail...

Страница 5: ...ate is figured in degrees per hour If you selected a rate of 100 per hour it would take 10 hours for the kiln to reach 1000 Rate is similar to miles per hour In summary the controller does three basic...

Страница 6: ...ress Advanced Features Note All the features in this section are available in a User Defined program The alarm is the only fea ture in this section that is available in a PMC pro gram This is because...

Страница 7: ...F 0 Cwillturnoffthealarm Lost Wax Burnout Caution Only kilns with vent holes are designed for lost wax burnout However you can use a kiln without the vent hole provided that you open the door during...

Страница 8: ...ent cover s or leave the door ajar Fire the kiln empty to 1500 F 815 C at a rate of 300 F 166 C with a one hour hold 01 00 Error Messages bAdP Bad Programming The kiln will not fire the because the Us...

Страница 9: ...ller You can calibrate the controller to fire up to 20 F 11 C hotter or cooler than the zero factory setting From press the key After rate temperature hold etc will appear With shown in the display pr...

Страница 10: ...art message appears after program ming a firing Press to begin firing Controller Calibration press the and Delay press the are accessed from the message Page 9 Calibrate the controller to fire hotter...

Страница 11: ...controller faceplate to the switch box Lift faceplate out of box and let the con troller hang on the outside of the box with the back of the board facing you Then plug the kiln back in Pro gram the co...

Страница 12: ...electing a Stored PMC Program Keys to Press Shown in the Display through Not Down Arrow Select Program 1 2 3 4 or 5 The kiln is now firing The User Defined Program Keys to Press Display through Not Do...