![Rinnai Symmetry RDV3610 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/rinnai/symmetry-rdv3610/symmetry-rdv3610_installation-manual_1462839003.webp)
Rinnai New Zealand Limited
RDV3610 Installation Manual: 11658-E
05-10
3
Before installation
Unpack the appliance and components and check for damage. DO NOT install any
damaged items.
Check all components have been supplied and that you have the correct gas type.
Read these instructions to get an overview of the steps required before starting the
installation. Failure to follow these instructions could cause a malfunction of the
appliance. This could result in serious injury and property damage.
Description
•
Direct vent inbuilt gas fireplace (natural draft)
•
Glass front
•
Convection fan (top air discharge)
•
Remote control, 7-day programmable timer
Recommended for a new build installation into a false (mock) chimney. Not suitable for
retrofitting into an existing masonry fireplace.
Combustion Method
Ceramic top pan burner
Data Plate
Centre front of base panel (behind the service panels)
Flue
Balanced flue: inner = 100 mm, outer = 170 mm
Appliance must be installed with a Rinnai supplied flue system
Gas Connection
½ “ BSP male flare
Gas Type
NG and General Product LPG
Heating Area
Heats up to 100 m
2
Ignition
Integrated sparker to pilot
Input/Output
Input: 19-33 MJ/h
Output: 4.2-7.5 kW
Noise Level
37-45 dB(A)
Power Consumption
High 50 W
Standby <1 W
Standard electrical connection is to the right side of the appliance
Safety Devices
Light to pilot, delayed ignition, overheat switch, electronic flame supervision (flame
failure), and combustion chamber pressure relief.
Temperature Control
Thermostatic, temperature control range 7-32 °C
Thermal Efficiency
80%
Weight
60 kg
Specification