background image

Symmetry RDV3610

Installation Manual

Appliance (including flue) is installed after framing and before cladding. Rinnai strongly 

recommend appliance is fully tested before any cladding materials are applied.

Cladding must be installed up to the flange and not over it. Any overhang will alter the 

performance of the appliance and cause an unsafe situation.

Appliance must be installed with a Rinnai supplied flue system.

Installation may require two people due to the size and weight of the appliance. 

Appliance must be installed, commissioned and serviced by a licensed tradesperson in 

accordance will all applicable local rules and regulations. 

Not intended as a fireplace insert

Содержание Symmetry RDV3610

Страница 1: ...the flange and not over it Any overhang will alter the performance of the appliance and cause an unsafe situation Appliance must be installed with a Rinnai supplied flue system Installation may requi...

Страница 2: ...stallation guide overview 9 Building the frame 10 Electrical connection 10 Bracket installation 11 Fixing the unit to the frame 12 Flue installation Rinnai flue kits 13 Flue installation Rinnai flue c...

Страница 3: ...into a false mock chimney Not suitable for retrofitting into an existing masonry fireplace Combustion Method Ceramic top pan burner Data Plate Centre front of base panel behind the service panels Flu...

Страница 4: ...Rinnai New Zealand Limited RDV3610 Installation Manual 11658 E 05 10 4 Dimensions mm 310 1090 715 510 890 995 500 1060 400 149 750 775 845...

Страница 5: ...etails The heater must be positioned on a flat level surface For installations further up the wall the heater needs to be supported either construct a base using board or support with joists These are...

Страница 6: ...installations If the Symmetry is being installed up the wall and close to the ceiling the recommended minimum clearance is 1000 mm Non combustible cladding Non combustible cladding such as 9 mm Eterpa...

Страница 7: ...oviding they are outside the minimum clearances shown below A Mantel height from top of fireplace 400 mm minimum B Mantel depth at 400 mm vertical clearance 300 mm maximum For every 50 mm of added man...

Страница 8: ...n installing a TV directly above the Symmetry RDV3610 or into a recess All dimensions are in mm Mantel 400 TV Rinnai DV3610 400 75 220 20 Flue Rinnai DV3610 Flue TV Directly Above Recessed The 400 mm...

Страница 9: ...f the steps are provided in the following pages Install brackets Symmetry unit and fix unit to frame Install flue and complete gas connection Install flue restrictor if required log set test pressures...

Страница 10: ...be located immediately below a socket outlet potential fire hazard The connection is either direct wired or connected to a power point within the cavity A 1500 mm power cord is supplied with a 3 pin p...

Страница 11: ...have brick rock veneer or tiles these sit tight up against the framing plate of the fireplace The metal mounting bracket adjusts 20 mm to allow for the different cladding thicknesses refer diagrams b...

Страница 12: ...ied with the unit into position These provide the required 150 mm minimum vertical clearance to the upper lintel 3 Fix unit to frame with the four mounting brackets These act as seismic constraints as...

Страница 13: ...lbow Flue pipe short 1 x 300 mm or Flue pipe long 2 x 230 mm Horizontal ashing kit Flue pipe 1 2 m Wall strap Roof cowl high wind Horizontal Flue Vertical Flue RDV3610 Flue Kit Horizontal A short R366...

Страница 14: ...o calculate what flue pipe length and or kit you may need 310 D 90 Elbow Cowl Flashing Kit 300 mm Pipe Interior wall 600 mm Pipe Base 1475 25 540 RDV3610 Short Horizontal Flue Kit A R3660 310 D 230 mm...

Страница 15: ...m clearance to combustible walls 150 mm R3630 230 mm R3631 300 mm R3632 450 mm R3633 600 mm R3634 900 mm R3635 1 2 m R3636 RDV3610 Flue Extension 75 175 mm R3638 75 360 mm R3639 Used for extending str...

Страница 16: ...11658 E 05 10 16 Flue installation 45 degree offsets Flue pipe length and code Offset mm Rise mm None bend to bend N A 124 340 150 mm R3630 203 419 230 mm R3631 257 473 300 mm R3632 311 527 450 mm R3...

Страница 17: ...ed with an approved Rinnai flue system Approved flue components for this appliance are detailed in this manual Clearance to combustibles Minimum clearance from inner flue to combustible material must...

Страница 18: ...fore any offsets 600 mm maximum horizontal length 3 5 m for vertical installations greater than 2 3 m flue restrictor is required to be fitted bends maximum of two Self supporting flue The weight of t...

Страница 19: ...with or without 45 bends maximum of two The shaded sections determine the position of the flue restrictor Min 0 6 m 3 0 m Max 5 4 m Max 1 8 m Restrictor position 2 4 2 m 1 8 m Restrictor position 3 Re...

Страница 20: ...ed to prevent any downward sags Horizontal pipe sections should be supported at least every 1 2 m Wall straps can be used for this purpose The horizontal run of flue pipe must have a 20 mm rise for ev...

Страница 21: ...m Wall straps can be used for this purpose The horizontal run of flue pipe must have a 20 mm rise for every 1 m of run towards the termination Never allow the flue pipe to run downward A downward slo...

Страница 22: ...rol on the lower left hand side of the appliance Gas pipe sizing must consider the gas input to this appliance as well as all other gas appliances in the premises 440 C L 190 60 Flared Union Connectio...

Страница 23: ...is can affect the performance of the fire Different flue configurations require a different positioning of the flue restrictor please refer to the Flue installation pages to determine what setting is...

Страница 24: ...ioning refer to the following YouTube video http www youtube com watch v xdxoKomYj9k Malfunctioning due to improper log rock placement is not covered under warranty The unit must never be used with br...

Страница 25: ...Middle Logs Ensure the middle elbow section rests on the top of the Bottom Log Position two of the rocks over the screw holes on the burner bed and place the remaining kidney shaped rock on top as sh...

Страница 26: ...Disconnect the solenoid yellow wire This will ensure the unit is on the lowest setting and set the appliance to the LOW setting Adjust the pressure as necessary Reconnect the solenoid Inlet test point...

Страница 27: ...lem with the fire such as blocked gas injectors or artificial logs burn media have shifted during installation There are some warning signs that could indicate a problem Unusual smell from the applian...

Страница 28: ...g must be installed directly above the fire as shown on page 6 When installing cladding ensure it is installed up to the flange and not over it any overhang will affect the performance of the applianc...

Страница 29: ...ratched or damaged in any way and that you have checked the gasket WARNING Inner frame Hook over the glass and secure in place on the two large lower magnets on the front assembly Outer frame Screw in...

Страница 30: ...ecklist in the customer operation manual and make sure you leave the manual with the customer Explain to the customer about the use and care of the unit and they understand the instructions and operat...

Страница 31: ...1 2 Gas Control Sparker Earth Flame Rod Sparker 5 4 2 3 1 1 2 CONTROL PANEL RECEIVER CONTROL UNIT IGNITION PACK 579 DBC SIT FAN MOTOR 10 9 8 7 6 Modulating Coil 50 Hz High Speed OH SWITCH 2 1 ACTIVE...

Страница 32: ...nukau 2150 Phone 09 257 3800 Fax 09 257 3899 Email info rinnai co nz Website www rinnai co nz All Rinnai appliances meet or exceed the safety standards required by New Zealand gas and electrical regul...

Отзывы: