background image

  Rinnai Smart Cylinder MP indoor stainless steel: Owner & installer guide: 20430-C 03-17   |   5

iQ automatic mode

This is the preset 

default mode for your 

Rinnai Smart Cylinder. 

In this mode the level 

indicator displays an estimate 

of the amount of hot water 

available in the tank. The level 

is monitored and updated in 

real-time.

There are five different 

settings available. Your Rinnai 

Smart Cylinder has been 

preset to operate on level 

three which will achieve a 

balance between energy 

savings and ensuring you 

have enough hot water 

available.

Level

Comfort 

level

Energy 

saving 

level

1

--

+++

2

-

++

3

+

+

4

++

-

5

+++

--

Changing the level setting

Press the + or - buttons and 

select the level you require—

if you don't press any button 

for three seconds the system 

will set the level change. 

The system will then default 

to showing the estimated 

amount of hot water in the 

cylinder again.

 

Manual mode

In manual mode the 

control regulates the 

water temperature 

in the cylinder to a preset 

level. The temperature level 

is selected by using the + 

or - buttons, there are five 

different settings available.

Level

Approx. water 

temp. in 
cylinder

1

50 °C

2

55 °C

3

60 °C

4

65 °C

5

70 °C

Biosafe operation

To meet the New Zealand 

Building Code requirement

1

 

to disinfect water for 

legionella bacteria

2

, the 

system will perform heating 

above 60 °C whenever risk 

conditions (<60 °C for 21 days) 

are detected.

Vacation mode

If you are going away 

switch the cylinder 

to vacation mode. In 

vacation mode the cylinder 

will be set to maintain 

the water at a minimum 

temperature of 6 °C to prevent 

the water from freezing.

To select press the mode 

button until the suitcase 

icon appears. By default the 

number of vacation days is 

undefined (--). If no period is 

selected the cylinder will stay 

in vacation mode until the 

mode is manually changed.

The number of days 

(maximum 99) can be 

specified by using the + or - 

buttons. A long press of the 

buttons will perform a fast 

speed day selection. After the 

specified period, the cylinder 

will automatically go back to 

the operating mode that was 

selected before vacation was 

set.

Vacation can be cancelled 

by pressing the iQ or manual 

mode buttons.

Warmup indicator

A slow blinking of the shower 

symbol indicates when the 

element is heating the water 

(occurs in automatic and 

manual modes).

default setting

1

 Clause G12.3.9, Acceptable Solution G12/AS1 6.14.3

Legionella is a bacterium that can cause Legionnaires’ disease―a severe form of pneumonia

Содержание Smart Cylinders MS13555030S

Страница 1: ...ers Mains pressure indoor stainless steel Owner and installer guide Models MS13555030S MS18055030S MS25055030S Installer Please leave this guide with the home owner as it contains important safety and warranty information ...

Страница 2: ...property damage personal injury or loss of life The appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction Important For more information about buying using and servicing of Rinnai appliances call 0800 RINNAI 0800 746 624 Rinnai New Zealand Limited 105 ...

Страница 3: ...ion Specification summary 12 Dimensions 13 Plumbing setup 14 Storage and delivery temperatures 15 Water quality 16 Electrical supply and connections 17 Valves and fittings 18 Commissioning 18 10 Year Limited warranty 19 Warranty examples in the real world 22 Proof of purchase 23 Installer details 23 ...

Страница 4: ...r a minimum of one week it will automatically adjust the cylinder heating times according to your hot water usage pattern A certain amount of hot water is guaranteed at all times depending on the level you select Manual mode Permanently maintains the total volume of water at a temperature according to the selected level operates just like a traditional electric storage cylinder Vacation mode Keeps...

Страница 5: ... 2 55 C 3 60 C 4 65 C 5 70 C Biosafe operation To meet the New Zealand Building Code requirement1 to disinfect water for legionella bacteria2 the system will perform heating above 60 C whenever risk conditions 60 C for 21 days are detected Vacation mode If you are going away switch the cylinder to vacation mode In vacation mode the cylinder will be set to maintain the water at a minimum temperatur...

Страница 6: ...ituation Do not reset the thermal cutout until the water heater has been serviced by a qualified person Do not operate the system unless all the safety devices are fitted and are in working order It is also important that you do not tamper or remove any of these devices Draining and filling the system This normally occurs during installation or servicing and must be carried out by an authorised pe...

Страница 7: ...icate a problem It is important that you raise and lower the easing gear gently During the operation if the valve does not discharge water when the easing gear is lifted or does not seal again when closed arrange for an authorised person to come and inspect the system immediately During servicing of your cylinder the TPR valve needs to be checked and or replaced This needs to be done by an authori...

Страница 8: ...he same time for more than three seconds I have cold water while in iQ automatic mode A sudden significant increase of hot water consumption may generate occasional cold water Change to manual mode and select the desired temperature level and then go back to iQ mode If this occurs regularly increase the level in iQ mode or occasionally go into manual mode Lack of hot water or no hot water Is there...

Страница 9: ...ugh the drain line If water is discharging continuously there may be a fault with one of the valves contact the installer to discuss Water is too hot If possible check the temperature of the water coming out of a hot water tap with a thermometer If it is higher than 55 C then this indicates a problem with your system contact an electrician for advice High electricity bills If you think your electr...

Страница 10: ...This page intentionally left blank ...

Страница 11: ...Installation Installation servicing and repair shall be carried out only by authorised personnel ...

Страница 12: ...161 5 kg 180 L 31 5 kg 211 5 kg 250 L 41 kg 291 kg Pressure limiting reducing valve This water heater MUST be installed with a 500 kPa or less pressure limiting valve and appropriate cold water expansion valve TPR valve A temperature and pressure relief valve is supplied with the water heater and MUST be fitted A TPR insulation kit to reduce heat loss is also supplied with the cylinders this also ...

Страница 13: ... all sizes Cold inlet female all sizes Hot outlet top of cylinder female all sizes Eco inlet Not applicable for Rinnai Smart Cylinders as they are not suitable for connecting to open loop solar or hot water heat pump systems Hot water outlet female Side cold inlet Element Side cold inlet TPR 40 40 45 Ø 550 mm 310 mm female side cold inlet all sizes Eco inlet TPR female TPR all sizes 325 mm Height ...

Страница 14: ...th to support the weight of the water heater when full The water heater must also be suitably restrained against seismic activity G12 AS1 Figure 14 details an acceptable method of restraint Drip tray catch pan MUST be fitted The Rinnai warranty does not cover any consequential loss from leaks to the cylinder so it s important a suitably drained drip tray catch pan is fitted as per AS NZS 3500 4 20...

Страница 15: ... all other buildings To comply with these requirements a temperature limiting device such as a tempering or thermostatic mixing valve will be required on all installations Pipe work It is the installer s responsibility to adequately size the distribution pipe work in a property to ensure sufficient performance from all outlet fittings Water pipe sizing should be performed in accordance with AS NZS...

Страница 16: ...d filtration experts be undertaken Hard water Hard water containing calcium carbonate can cause scaling on hot surfaces We recommend a water temperature of no more than 65 C to minimise scale build up Scale reducing or water softening devices should be considered in hard water areas The unit is not guaranteed against damage due to scaling Water quality outside the limits as set down below will voi...

Страница 17: ... capable of withstanding the appliance load Fixed wiring must be protected from contact with the internal hot surface of the water heater Electrical access is via a hole in the element cover for mounting with an approved electrical conduit gland For entry to the element cover remove the two fixing screws Connect all Live Neutral and Earth wires in accordance with the wiring diagram Inspect and ens...

Страница 18: ...e isolating switch to the water heater 2 Close the cold water isolation valve at the inlet to the water heater To drain the water heater 1 Turn off the water heater as above 2 Close all the hot water taps 3 Gently operate the TPR valve release this will relieve the pressure in the water heater 4 Open the drain valve make sure no damage will occur from discharged water 5 Operate the TPR valve again...

Страница 19: ... for commercial purposes hair salon catering kitchen communal care facility etc These installations would be considered commercial applications An exception would be an accommodation business such as a motel where the water heater serves the equivalent of a single family dwelling this would be a residential application General warranty terms Rinnai reserves the right to make modifications and chan...

Страница 20: ... is difficult a service charge will apply If at the discretion of the attending service person the installation is deemed illegal or access is dangerous service will be refused Any work required to gain reasonable access to the cylinder will be chargeable by the attending service person for example removal of cupboards doors walls or the use of special equipment to move components but not limited ...

Страница 21: ...Where the cylinder has failed directly or indirectly as a result of poor water quality outside the limits specified 6 Where it is found that there is no fault with the cylinder and the issue is related to the installation or is due to power failure 7 Subject to any statutory provisions to the contrary Rinnai does not accept a liability for consequential damage or any incidental expenses resulting ...

Страница 22: ... Yes All costs covered by Rinnai Faulty element 3 years No All costs covered by the owner Cylinder leaks as a result of a faulty inner cylinder and causes damage to carpets and flooring 11 months Yes No Cost of cylinder replacement covered by Rinnai Consequential loss damage to carpets and flooring is not1 1 Consequential losses All cylinders are required to be installed with a drip tray this is a...

Страница 23: ...or future reference ATTACH YOUR PROOF OF PURCHASE HERE RECORD YOUR DETAILS OF PURCHASE BELOW Retailer Retailer address Date of purchase Product details Proof of purchase Installer details Company name Installer name Address Phone Mobile Signed Date Product registration You can register your product online at rinnai co nz register ...

Страница 24: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz a touch of magic 20430 C ...

Отзывы: