GAS INSTANTANEOUS WATER HEATER

INSTRUCTIONS

MODEL

RUS-51FT

This Appliance shall be installed in accordance with:-

Manufacturer’s Instructions.
Local Gas Fitting Regulations.
Local Body Building Codes.
Installation Code for Gas Burning Equipment.
Any other relevant statutory regulation.
This appliance must be installed by an authorised person.

RUS-51FT.PM6

Содержание RUS-51FT

Страница 1: ...hall be installed in accordance with Manufacturer s Instructions Local Gas Fitting Regulations Local Body Building Codes Installation Code for Gas Burning Equipment Any other relevant statutory regula...

Страница 2: ...Changeover switch or the Control Water Temperature Knob Battery Changeover Indicator The Indicator informs of the necessity to change the battery before it goes flat One touch Operation The unit has...

Страница 3: ...safe combustion prevention device to put the flame out Turn the appliance off Do not use this water heater in a bathroom Be particularly careful to provide sufficient ventilaton An open kerosene heate...

Страница 4: ...ins CAUTION TO Avoid Burns After using the heater at the BOIL setting return the control to a lower temperature setting this will reduce the risk of burns to the next person Do not touch anything apar...

Страница 5: ...iclockwise The water flow will decrease as the temperature increases CAPACITY CHANGEOVER When water temperature is high in Summer etc turn the capacity changeover level to low These will lessen gas fl...

Страница 6: ...g hot water as spray may cause burns TO DRAIN THE HEATER if freezing conditions are expected 1 Turn the water and gas off at the control valves 2 Change the shower to the straight mode and bend the ou...

Страница 7: ...around the unit Is there a smell of gas Is there a water leak in the unit or connecting parts BATTERY REPLACEMENT If the spark speed slows down replace the batteries as shown Batteries should last ove...

Страница 8: ...ter is best installed at eye level provided the required clearances can be maintained Clearances shown must be maintained at all times 6 The wall must be strong enough to support the heater 10kg 7 Wat...

Страница 9: ...as Check the unit is not too close to combustibles nothing obstructing daily use and maintenance that accessories have been installed correctly and that the unit is firmly attached When installation i...

Страница 10: ...MJ h 42 0 NG 38 0 LPG CAPACITY TEMPERATURE 11 80 C rise VOLUME 1 6 4 51 min WATER VOLUME CONTROL Water Governor System MIN OPERATING WATER PRESSURE Min 35 kPa MAX OPERATING WATER PRESSURE 500 ELECTRI...

Страница 11: ...ator lights up it will not light up or flash when the knob is turned to COLD or if instant ignition is difficult the batteries should be replaced Water flow is low and the flame fails during operation...

Страница 12: ...er is flowing continuously the unit s flame will cut out after 15 20minutes The water will continue to flow Press the control knob to stop the water flow when you notice the flame has cut out WARNING...

Страница 13: ...An overhaul by an appropriate serviceman is recommended if the unit gets extremely dirty 3 This unit is suitable for domestic use If it is used heavily eg In a cafe ensure frequent check ups for the...