background image

Comple

13

TESTING & COMMISSIONING

 TESTING PROCEDURE

Turn gas supply on and plug the unit into the power supply. (Caution 240V.)

 TO CHECK BURNER PRESSURE

  Refer to Data Plate.

•   

Remove the wiring cover panel.

  Remove test point screw and attach manometer to test point.

   The test point is on the front side of the gas valve.

  Light heater, turn to High heat setting and

    check pressure.

  If adjustments are necessary, the regulator is situated on

    the front of the gas control.

•  

After checking pressure, turn the unit off, remove manometer and replace test point screw.

•  

Turn the heater on and off a few times to check ignition.

•  

When you are satisfied that the heater is working correctly, reassemble panels.

•  

All burner aeration is factory preset and cannot be adjusted.

•  

If you are unable to get the unit to operate correctly, refer to Troubleshooting on Page 9,

   before contacting your local service contact as listed on Page 14.

•  

It may take approximately 2 hours for the logs to achieve their full flame pattern and glow.

  

During the initial burning in period, some smoke and smell may be experienced. The

   heater should be run on the high position in a well ventilated room until these dissipate.

It is the responsibility of the installer to check that under normal operating conditions of the
appliance, all flue gases are exhausted to the outside atmosphere and that there is no spillage
of combustion gases into the room. Please refer to AS5601 / AG601 clauses 5.13.3.3

 INSTRUCT CUSTOMER ON USE OF UNIT

Explain to customer about use and care of unit.  Make sure the customer understands the instructions.

 EXPLAIN TO THE CUSTOMER

Ignition, Adjusting heat level, Fan Switch, Turning “OFF”.

The guard on this appliance conforms to AGA. requirements. It is designed to prevent the risk of
fire or injury from burns, and no part of it should be permanently removed.

IT DOES NOT GIVE FULL PROTECTION TO YOUNG CHILDREN OR THE INFIRM.

 COMMISSIONING

 

INSTALLATION AND COMMISSIONING CHECKLIST

Complete the installation / commissioning checklist and the installer / gasfitter details on page 12 and
make sure that this instruction book is left with the customer.

NOTE:

RINNAI RESERVES THE RIGHT TO CHANGE OR MODIFY SPECIFICATIONS WITHOUT NOTICE.

Содержание Royale ETR Freestanding

Страница 1: ...on 11 Log Installation 12 Testing Commissioning 13 Technical Data 14 Service Contact Points 14 Wiring Diagram 15 Installation Checklist 16 Installer Details 16 IMPORTANT This appliance shall be installed in accordance with Manufacturers Installation Instructions Local Gas fitting regulations Municipal Building codes Gas Installation Code AG5601 AG601 NZ 5261 Any other relevant statutory regulation...

Страница 2: ... TIME TEMP Display Shows either the time of day temperatures or coded error messages CLOCK ADJUSTMENT AND TIMER INDICATORS Indicates that clock or dual timer programme is being set OVERRIDE Temporarily changes operation from ON to OFF or OFF to ON until next programmed setting is reached AUTO OFF When ON Thermostat turns heat down to OFF When OFF Thermostat turns heat down to LOW Flame Function Me...

Страница 3: ...FF button OFF then ON again DO NOT turn off by unplugging at the power point The fan will continue to run until the appliance cools The room temperature and pre set temperatures can only be displayed and adjusted when the heater is running If the heater does not ignite then the pre set temperature may not be set to a setting which is higher than the room temperature The ON indicator will change co...

Страница 4: ...elected simply press the ON or OFF button To alter the temperature at anytime while the heater is operating simply press the or buttons Remote Control will not turn heater ON if Timer s have been selected ON BUTTON Operates the heater manually OFF BUTTON Stops heater manually TEMPERATURE ADJUSTMENT Increases or decreases the temperature setting TO REPLACE BATTERY Simply open the back of the remote...

Страница 5: ...e Set Times button twice The Digital Display will show AM 6 00 Timer 1 indicator will flash Press the button until AM 7 00 appears release the button then press it again until AM 7 10 appears Press the button if you go past AM 7 10 Press the Set Times button again the Timer 1 OFF indicator will flash Press the button until AM 9 00 appears Press the button if you go past AM 9 00 Press the Set Times...

Страница 6: ...he programmed starting time It will attempt to heat a room by the programmed starting time See Pre heat page 6 for further explanation If there is a power failure the system memory will retain the Timer programs and the clock will stop at the time the power goes off The clock will start again when the power comes back on but the time will be slow by the duration of the power failure To set the clo...

Страница 7: ... Overheat Service call 16 Room Overheat Lower room temperature to less than 40ºc 3 1 Room temperature Sensor Faulty Service call Overheat temperature Sensor Faulty 32 Room temperature Sensor Faulty Service call 33 Service call 70 Faulty ON OFF Switch Service call 7 1 Faulty Solenoids Service call 72 Faulty Flame Rod Service call 73 Communication error Turn heater OFF then ON again 99 Flue Block Se...

Страница 8: ... body contact with the louvres should be avoided Do not allow young children or the infirm to sleep directly in front of the heater Do not allow anyone to sit on or lean against the appliance Do not allow anyone to post articles through the louvres Do not allow curtains or other flammable or combustible materials to come into contact with the heater SAFETY POINTS 8 DO NOT PLACE ARTICLES ON OR AGAI...

Страница 9: ...nsure power cord is plugged in and turned on Power cut Re ignite after power is restored Air in gas pipe Purge air installer Ignition Failure Repeat lighting procedure refer page 3 No gas present Ensure gas supply is turned on Smell of gas Leaking gas Turn gas off at meter and call installer Fan not working Heat switch not activated Allow heater to run on HIGH for 15 minutes minimum Fan not turned...

Страница 10: ...ct with it In some cases curtains may need restraining See below for minimum clearances required 4 The heater is not designed to be built into bookcases or shelves or any combustible opening 5 Check that room ventilation complies with local regulations 6 Check that an EARTHED power point is within 1500mm of the right hand side of the heater 7 The heater does not require any additional hearth or fl...

Страница 11: ...eater requires a minimum 3m flue Position the heater Suspend a plumbline from the ceiling to the centre of the flue socket Mark the centre of the flue in the ceiling Make a small hole in the ceiling and double check that the flue system will be at least 25 mm clear of combustible materials Cut the hole for the flue Fit the ceiling plate flue and decorative cover The decorative cover must be able t...

Страница 12: ... pins of the Main Log as shown Gently place loose ember bed material in front of the front log Do not pour as dust particles from the plastic bag may block the burner ports Level it with a pencil or screwdriver and remove excess material Note The ember bed material must be placed after the logs are fitted If the logs are to be removed for any reason the ember bed material must be removed first and...

Страница 13: ... During the initial burning in period some smoke and smell may be experienced The heater should be run on the high position in a well ventilated room until these dissipate It is the responsibility of the installer to check that under normal operating conditions of the appliance all flue gases are exhausted to the outside atmosphere and that there is no spillage of combustion gases into the room Pl...

Страница 14: ...mination Ignition Power Supply Fan Data Plate TECHNICAL DATA 14 SERVICE CONTACT POINTS RINNAI AUSTRALIA PTY LTD ACN 005 138 769 Helpline 1300 366 388 Mon Fri 8 30am 5 30pm EST Cost of a local call higher from mobile or public phones Internet www rinnai com au Email enquiry rinnai com au Head Vic Tas 10 11 Walker St Braeside Vic 3195 Office Tel 03 9271 6625 Fax 03 9271 6622 Sales Tel 03 9271 6666 F...

Страница 15: ...WIRING DIAGRAM 15 ...

Страница 16: ...eplace 8 Has the appliance been commissioned 9 Is the end user fully aware of operating procedure NO YES INSTALLER GASFITTER DETAILS Company Name ____________________________________________________________________ Gasfitters Name ____________________________________________________________________ Address ____________________________________________________________________________ _______________...

Отзывы: