15
RIN0421 023335 Rev. E Jun 2013
Owner’s Manual
80L to 400L Electric Storage Water Heaters
Version B: Update to new logo and reduce size of label
b. any labour required to gain
access to and to bring the unit
to a position that complies with
the installation instructions or
relevant statutory requirements.
9.
Any claim under the warranty or
replacement guarantee must include
full details of the defect and/or
damage to the hot water unit and/
or component in the hot water unit.
All claims must be made within one
month of the detection of the defect.
10.
This warranty applies to water
heaters connected to a water
supply where the water chemistry
and impurity levels do not exceed
the limits specified in Table 1 below.
The water supply from water utilities
is deemed to comply with these
requirements.
This warranty does not apply to
water heaters connected to water
supplies if the water chemistry
and impurity levels exceed the
limits specified in Table 1 below.
Examples of water supplies where
chemistry and impurity levels may
exceed the limits specified in Table 1
include but are not limited to private
bores, private dams and water from
water utilities where the chemistry
is deliberately altered by parties
other than the water utility before
supplying the water heater.
11.
This warranty does not apply to
damage caused by sludge and/or
sediment in the water supply.
Warranty
Table 1 – Water Characteristics
Total Dissolved
Solids (TDS)
mg/Litre or
ppm
Hard-ness
(as CaCO3)
mg/Litre or
ppm
Saturation
Index
(Langelier)
pH
Dissolved
CO2
mg/Litre or
ppm
Chlorides
mg/Litre or
ppm
2500*
200
+0.4 to – 1.0 @
65
°
C
5.5 to
9.5
Not
Applicable
Not
Applicable
* For TDS levels up to and including 600mg/litre the Rinnai magnesium based anode is to be
used. This is the anode fitted during manufacture of the cylinder. For TDS levels greater than
600mg/litre and not exceeding 2500mg/litre the Rinnai aluminium based anode is to be used.
This anode can be fitted by Rinnai or an authorised person. This warranty does not apply if