This appliance can be installed in ducted or recirculation 
mode. 

Ducted mode 

(Fig. 4) 

x

In ducted mode, the extractor hood fan extracts the
cooking vapours and passes them through the 
grease  filter. The air then flows to the outside. 

x

The grease filter absorbs the solid particles in the
cooking vapors. 

x

In this mode, 

only grease filters are installed

(charcoal filter is optional)

Fig. 4 

Recirculation mode 

(Fig. 5) 

x

In recirculation mode, the extractor hood fan
extracts the cooking vapors which are purified in the 
grease filter and charcoal filter. 

x

The purified air is then recirculated into the kitchen
via a vent opening in the hood. The grease filter 
absorbs the solid particles in the cooking vapors. 

x

The charcoal filter is designed to absorb cooking
odor. In this mode, 

both grease filters and charcoal 

filters are installed.

 

Fig. 6 

Connection 

(Fig. 7) 

x

For 

ducted 

mode:

o

Use Ø 120mm pipe (flexible if possible) and fix it
with a pipe-tightening ring (not provided) at the
reduction fitting.

o

Connect the pipe to the outdoor duct.

o

Remove  charcoal  filters  and  use  only  grease

o

filter for more powerful suction.

x

For 

recirculation 

mode:

o

Insert the charcoal filters.

   Fig. 7 

  Fig. 5 

Fitting into wall cabinet  

(Fig. 6) 

Do  ensure  that  the  appliance  is  mounted  on  a  solid 
surface which could withstand the appliance’s weight. 

x

The hood support must be 180mm above the

bottom of the wall cabinet. 

x

For 

ducted mode 

version, cut a minimum 

Ø 

140mm

duct hole on hood support. 

x

Lift the hood into the cabinet from below.

Secure using 4 (four) M5 x 35

 

screws provided. 

Installation must be performed by qualified personnel only. The manufacturer declines all responsibility for improper 
installation and does not accept responsibility for appliance warranty in the event of damage caused by incorrect 
installation. 

Содержание RH-TL65C-SSVR

Страница 1: ...Cooker Hood Instructions for use installation and connection RH TL65C SSVR RH TL75C SSVR RH TL95C SSVR ...

Страница 2: ...ance and care 7 Troubleshoot 8 CONTENTS IMPORTANT To register your product warranty please paste the serial numbers stickers enclosed with the packaging on your warranty card Please contact your local Rinnai Customer Care Centre should you require further assistance Version 2019 0 ...

Страница 3: ...can be installed over gas and electric cook top Minimum installation height from the bench top to the bottom of the hood is 700mm gas range and 550mm electric range Fig 1 For the user x The extractor hood is designed for domestic use to eliminate unpleasant odors from the kitchen Do not use the hood for uses other than its specific purpose x Do not allow young children to play with or operate the ...

Страница 4: ...epts no responsibility for complaints attributed to the design and layout of the pipe work x Do not flambé or grill with an open flame directly under the extractor hood Flames could be drawn up into the hood by the suction and the grease filters may catch fire x Monitor cooking continuously as overheated oil increases the risk of self ignition x Do not operate the extractor hood without a grease f...

Страница 5: ...l imporvement or modification without prior notice 130W Appliance Dimension 220V 240V 50 60Hz 1 5m W x D x H mm F 4 Screw M5 x 35 G 4 Screw ST4 x 30 H 4 Wall plug T8 x T6 Qty DocumentaƟon 1 OperaƟon InstallaƟon Manual 2 InstallaƟon Diagram 1 Warranty sƟcker Ref Qty Product components A 1 Duct connector B 1 Hood body includes Blower Switch control Light Filters sliding Carriage C 1 Front exhaust pl...

Страница 6: ...filters and charcoal filters are installed Fig 6 Connection Fig 7 x For ducted mode o Use Ø 120mm pipe flexible if possible and fix it with a pipe tightening ring not provided at the reduction fitting o Connect the pipe to the outdoor duct o Remove charcoal filters and use only grease o filter for more powerful suction x For recirculation mode o Insert the charcoal filters Fig 7 Fig 5 Fitting into...

Страница 7: ... completely removed Speed settings Fig 8 ඹ HIGH Switches the fan on at high speed ය OFF Switches the fan off ර LOW Switches the fan on at low speed The motor automatically regulates on off by opening closing the sliding carriage The motor works according to the last speed selected when sliding carriage is opened ඹ ය ර Fig 8 Light Fig 9 ON Switches the light system on ල OFF Switches the light syste...

Страница 8: ...ctor hood using warm detergent solution and a soft damp cloth Wipe dry with a lint free cloth x Avoid using corrosive or abrasive products that could damage the surface Light replacement Fig 12 Replace the light with another which has the same characteristics A higher voltage bulb could damage the electrical unit x Removing and replacing the light o Remove grease filters and push out the light o K...

Страница 9: ...irring sound Foreign object may be in contact with fan blade Please contact Rinnai Customer Care Service Lights are not working ŝŐŚƚ ďĂƌƐ ĂƌĞ ďůŽǁŶ ŽƵƚ ZĞƉůĂĐĞ ƚŚĞ ĚĂŵĂŐĞĚ ůŝŐŚƚ ŝŐŚƚ ďĂƌ ĐŽŶŶĞĐƚŝŽŶ ĂƌĞ ůŽŽƐĞ ZĞƐĞƚ ƚŚĞ ĐŽŶŶĞĐƚŝŽŶ English If problem persists after the above checks please contact Rinnai Customer Care Centre for assistance Please quote the model number of your appliance as shown on th...

Страница 10: ...ŶĚ ประเทศไทย ZŝŶŶĂŝ dŚĂŝůĂŶĚͿ Ž ƚĚ ƵĐŬLJ ůĂŵĞ Ž ƚĚ ϲϭ ϭ Žŝ ŝŶŐŬĂĞǁ ϵ ŝŶŐŬĂĞǁ ZĚ ZĂĐŚĂ dŚĞǁĂ ĂŶŐƉŚůŝ ĂŵƵƚƉƌĂŬĂƌŶ ϭϬϱϰϬ dŚĂŝůĂŶĚ บริษัท รินไน ประเทศไทย จํากัด เลขที ซอยกิงแก ว ถนนกิงแก ว ตําบลราชาเทวะ อําเภอบางพลี จังหวัดสมุทรปราการ ประเทศไทย dĞů ϲϲͿ Ϯ ϯϭϮϰϯϯϬͲϰϬ ŵĂŝů ůƵĐŬLJϬϮΛůƵĐŬLJĨůĂŵĞ ĐŽ ƚŚ hZ ǁǁǁ ůƵĐŬLJĨůĂŵĞ ĐŽ ƚŚ DĂůĂLJƐŝĂ ZŝŶŶĂŝ DͿ ĚŶ ŚĚ ϮͲϯͲ Θ ϮͲϯͲϭ ůŽĐŬ Ϯ WƵƐĂƚ WĞƌĚĂŐĂŶŐĂŶ ĂŶĂ ϭ ĂůĂŶ W h ϭ ϰϲ ϰϳ...

Отзывы: